Information
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
Berms and Drainage
-
Acceptable berm wall integrity (free from cracks, openings, erosion)
-
Berm and drainage free of excessive vegetation and weeds
-
Drain valves locked and/or sealed
-
Berm capacity (free of fluids)
Tanks and Vessels
-
Tanks and vessels free of drips, leaks, weeps
-
Tanks and vessels free of corrosion
-
Tanks and vessels free of integrity issues such as cracks, bulges, distortions, or warping
-
Tanks and vessels free of foundation issues such as gaps between tank and damaged foundation
-
Evidence of adequate drainage (no standing water)
-
Condition of the insulation satisfactory (no tears, evidence of oil, CUI)
-
Grounding system (adequately grounded, no leads disconnected)
-
Condition of associated piping
-
Appurtences (i.e. man ways, thief hatch, gas blankets, dikes, trash, vegetation, CP, ladders, stairways, platforms
-
Foundation (no signs of settlement)
-
Plugs in place at all single block bleed points
Pumps, Piping, Valves, & Fittings
-
Pumps, piping, valves, and fittings free of drips, seeps, weeps, leaks, spills, corrosion, and evidence of impact
-
Supports, footings, foundations
-
Labeling of pumps, piping, valves, and fittings
-
Pipe coating at soil surfaces and through walls and dikes
-
Required locks or seals in place on all pumps, piping, valves, and fittings
-
Plugs in place at all single block bleed points
-
Pressure Relief Valves installed correctly and tag up to date
Portable Equipment
-
Portable equipment free of drips, leaks, weeps, and corrosion
-
Portable equipment free of integrity issues such as cracks bulges, distortions, or warping
-
Condition of the insulation satisfactory (no tears, evidence of oil, CUI)
-
Grounding System (adequately grounded, no leads disconnected)
-
Condition of portable equipment associated piping (satisfactory)
-
Appurtences (i.e. man ways, thief hatch, gas blanket, dikes, trash, vegetation, CP, ladders, stairways, and platforms
-
Plugs in place at all single block bleed points
-
Pressure relief valves installed correctly and tag up to date
Electrical
-
Electrical equipment free of excessive vegetation and weeds
-
Labeling of electrical enclosures
-
Electrical cords in acceptable condition (no exposed wires)
-
Grounding system (adequately grounded, no leads disconnected)
Well Cellar
-
Confined space sign near cellar if applicable (not required if <4")
-
Cellar free of all fluids
-
Cellar properly covered
-
Adequate berms around cellar
Well Head
-
Proper well sign that includes Operator Name (unless exempt), Lease Name (if applicable), and Well #
-
Proper well sign if on BLM that also includes section, township, range, quarter section, BLM number, and/or SAC code
-
Wellhead free of drips, leaks, weeps, and corrosion
-
Minimum of 15' clearance of all weeds or brush from wellhead
-
Casing vents are closed unless permitted by air district
-
Plugs in place at all single block bleed points
Pumping Unit
-
Pumping unit tie downs and structure free of loose bolts
-
Flag pin and throat bolt installed properly
-
Lube line connected and free from holes or leaks
-
Pumping unit contains well sign and other hazard identifiers (Danger H2S May Be Present)
-
Rod and/or tubing rotator in place and properly hooked up
-
Accurate well # on walking beam
-
Adequate clearance between stuffing box and carrier bar
-
Pumping unit fence guards in place and secured
-
Pumping unit pad free of cracks, erosion, excessive vibration or movement during operation
-
Pumping unit head aligned with unit
-
Gear box free of leaks
-
Pumping unit and gear box free of unusual noise
Access Roads
-
Locations / Roads free of standing fluids
-
Free of surface expressions / depressions, heat cracks, or mounds
-
Access to the facilities is unimpeded
SPCCC
-
Pit, EOB, or sump free of excessive fluids
-
Netting in acceptable condition
-
Fencing in acceptable condition
-
Location free of evidence of animal entrapment and animal droppings
General
-
General housekeeping on entire location
-
Site free of unnecessary hazardous waste
-
Appropriate Restricted Access / Danger signs on location
-
Chemical containers properly labeled (Aera Chemical PPE, NFPA 704 Diamond, Product Name, etc)
-
Green house gas log on location and filled out daily for completeness (all portable internal combustion equipment)
-
Add signature