Title Page

  • Site conducted

  • Conducted on

  • Location

  • Prepared by

  • Job completed by

Main page

General observations and recommendations

  • Observations and recommendations EIC/EICR

Installation details and access

  • Property description

  • Access granted yes/no

  • Access granted to main electrical intake yes/no

Intake equipment (visual inspection only)

  • Service cable

  • Service head

  • Earthing arrangement

  • Isolator (where present)

  • Sub-Main cable size

  • Consumers isolator (where present)

  • Metering equipment

  • Consumer’s meter tails

  • Consumer’s meter tails size mm

Earthing/Bonding arrangements

  • Presence and condition of distributor’s earthing arrangements.

  • Earthing conductor size (mm2)

  • Provision of earthing/bonding labels at all appropriate locations

  • Accessibility and condition of earthing conductor and MET

  • Presence and condition of main protective bonding conductors

  • Main protective bonding conductors size (mm2)

  • Condition and accessibility of main protective bonding conductor connections

  • Accessibility and condition of other protective bonding connections

  • Main protective bonding confirmed to

Supply characteristics and earthing arrangements

  • Earthing arrangements

  • Number of live conductors

  • Ze (ohms)

  • PFC

  • Nominal voltage V

  • Supply Protective Device BS(EN)

  • Supply Protective Device Type

  • Supply Protective Device rated current

  • Confirmation supply polarity

Consumer Units

  • Adequacy of working space/accessibility to consumer unit

  • Security of fixing

  • Condition of enclosure in terms of IP rating

  • Condition of enclosure in terms of fire rating

  • Condition of enclosure

  • Operation of main switch

  • Manual operation of MCBS/RCBOS/AFDDS

  • Correct identification of circuit details and protective devices

  • Presence of RCD six-monthly test notice

  • Presence of other required labelling

  • Compatibility of protective devices and other components, correct type and rating

  • Protection against mechanical damage where cables enter consumer unit

  • RCDs provided for additional protection

  • Confirmation of indication that SPD is functional.

  • Confirmation that AFDD is fitted for requited circuits

  • Confirmation that ALL conductor connections are correctly located in terminals and are tight and secure

Final Circuits

  • Identification of conductors

  • Cables correctly supported

  • Condition of insulation of live partsk

  • Non-sheathed cables protected by enclosure in conduit, ducting or trunking

  • Adequacy of cables for current-carrying capacity

  • Coordination between conductors and overload protective devices

  • Adequacy of protective devices: type and rated current for fault protection

  • Presence and adequacy of circuit protective conductors

  • Wiring system is appropriate for the type and nature of the installation and external influences

  • Provision of additional requirements for protection by RCD not exceeding 30mA

  • Provision of fire barriers and sealing arrangements

  • Termination of cables at enclosures (mechanically and electrically sound)

  • Condition of accessories

  • Suitability of accessories for external influences

Locations containing a bath or shower

  • Additional protection for all low voltage circuits by RCD not exceeding 30mA

  • Presence of supplementary bonding conductors

  • Low voltage socket outlets sited at least 2.5 m from zone 1

  • Suitability of equipment for external influences for installed location in terms of IP rating

  • Suitability of accessories and control gear for particular zone

  • Testing sampling Test Results
  • Circuit description

  • Type of wiring and Reference method

  • Number of points

  • Live (mm2)

  • CPC (mm2)

  • Overcurrent protective device

  • RCD/RCBO/AFDD Type

  • RCD/RCBO/AFDD Operating current (mA)

  • RCD/RCBO/AFDD Breaking capacity (kA)

  • Main RCD details (if present)

  • Ring circuit r1 value (ohms)

  • Ring circuit rn value (ohms)

  • Ring circuit r2 value (ohms)

  • R1+R2

  • Insulation resistance test voltage V

  • Live-Live (Mohms)

  • Live-Earth (Mohms)

  • Polarity

  • Maximum measured Zs

  • RCD disconnection time (ms)

  • RCD/RCBO/AFDD test button operation

Fire Detection check

  • Fire defection Grade and Category

  • Number, location, type and expiry dates of smoke detectors

  • Fire Alarm functional check

  • Smoke detectors connected to permanent supply

  • Smoke detectors/trunking fixed using screws

  • FD certificate is available and correct

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.