Title Page

  • Site conducted

  • Conducted on

  • Prepared by

  • Location
  • Home number

  • Home name

Switched spurs

Lounge fire

  • Electric lounge fire installed?

  • Plugged in

  • 13 amp fuse fitted

  • Functional

Towel radiators

  • Towel radiators installed?

  • Number installed

  • Bathroom: en-suite 1

  • Bathroom: en-suite 2

  • Bathroom: 1

  • Bathroom: 2

  • Bathroom: 3

  • Additional bathrooms?

  • How many?

  • 3 amp fuse fitted to all

  • All functional

Appliances

Cooker hood connected

  • Cooker hood installed?

  • 3 amp fuse fitted

  • Blue plug connected

  • Functional

Microwave

  • Microwave installed?

  • Plugged in

  • 13 amp fuse fitted

  • Identity label fitted

  • Polarity correct

  • Functional

Washing machine

  • Washing machine installed?

  • Plugged in

  • 13 amp fuse fitted

  • Identity label fitted

  • Polarity correct

  • Functional

Tumble dryer

  • Tumble dryer installed?

  • Plugged in

  • 13 amp fuse fitted

  • Identity label fitted

  • Polarity correct

  • Functional

Dishwasher

  • Dishwasher installed?

  • Plugged in

  • 13 amp fuse fitted

  • Identity label fitted

  • Polarity correct

  • Functional

Plinth heater

  • Plinth heater installed?

  • Plugged in

  • 13 amp fuse fitted

  • Identity label fitted

  • Polarity correct

  • Functional

Hot tap

  • Hot tap installed?

  • Plugged in

  • 13 amp fuse fitted

  • Identity label fitted

  • Polarity correct

  • Functional

Warming drawer

  • Warming drawer installed?

  • Plugged in

  • 13 amp fuse fitted

  • Identity label fitted

  • Polarity correct

  • Functional

Fridge/freezer

  • Fridge/freezer installed?

  • Plugged in

  • 13 amp fuse fitted

  • Identity label fitted

  • Polarity correct

  • Functional

Fridge

  • Fridge installed?

  • Plugged in

  • 13 amp fuse fitted

  • Identity label fitted

  • Polarity correct

  • Functional

Freezer

  • Freezer installed?

  • Plugged in

  • 13 amp fuse fitted

  • Identity label fitted

  • Polarity correct

  • Functional

American fridge

  • American fridge installed?

  • Plugged in

  • 13 amp fuse fitted

  • Identity label fitted

  • Polarity correct

  • Functional

Wine cooler

  • Wine cooler installed?

  • Plugged in

  • 13 amp fuse fitted

  • Identity label fitted

  • Polarity correct

  • Functional

Hob on grid

  • Hob on grid installed?

  • Plugged in

  • 3 amp fuse fitted

  • Identity label fitted

  • Polarity correct

  • Functional

Hob own circuit

  • Hob own circuit installed?

  • Isolator functional

  • Cooker nose fitted

  • 4mm heat resistant flex installed

  • Hob secured

  • Ceramic hob fire board installed under hob

  • Induction hob 25mm air space under hob

Single oven

  • Single oven installed?

  • Isolator functional

  • Plugged in

  • 13 amp fuse fitted

  • Identity label fitted

  • Polarity correct

  • Functional

  • Oven securing screws installed

Double oven

  • Double oven installed?

  • Isolator functional

  • Cooker nose fitted

  • 4mm heat resistant flex installed

  • Functional

  • Oven securing screws installed

  • Fan isolator installed?

  • 3 amp fuse fitted

  • Does it only isolate the room it controls?

Extractor fan

  • Extractor fan installed?

  • Identity sleeved

  • Fan switches on with light

  • Overrun when light off

Velux windows

  • Velux windows installed?

  • Programmed remote control

  • Programmed blind

  • 1 controller for blind in home

  • 1 controller for window in home

  • Switched spur white

  • 3 amp fuse fitted

  • Functional window and blind check

Bluetooth speaker system

  • Bluetooth speaker system installed?

  • Sound jumper set to high

  • Jumper set to stere

  • 3 amp fuse fitted

  • Switched spur label

Tube heater

  • Tube heater(s) installed?

  • White switch socket fitted

  • 3 amp fuse fitted

  • Plugged in

  • Polarity

  • Functional

Switches

1 way

  • Lightly tap faceplate, lights are flicker free

  • Switch controls the correct light(s)

  • Switch rocker seated correctly

2 way

  • Are 2 way light switches installed?

  • Lightly tap faceplate, lights are flicker free

  • Switch controls the correct light(s)

  • Switch rocker seated correctly

  • Lights switch correctly using 2 way from other light switch

Intermediate

  • Are intermediate switches installed?

  • Lightly tap faceplate, lights are flicker free

  • Switch controls the correct light(s)

  • Switch rocker seated correctly

  • Lights switch correctly using 2 way from other light switch

Dimmers

  • Are dimmers installed?

  • Dimmer set top trailing edge

  • DIP switch is on

  • Minimum dim function been set in the dip switches

  • Switch dimmer off

  • DIP switch to ON

  • Lower to the required minimum brightness

  • Change DIP switch 1 to OFF

  • Confirm light brightens slightly, to confirm minimum brightness setting

Plinth lights

  • Are plinth lights installed

  • Cables tied up neatly behind plinth

  • Blue plug connected

  • Driver installed

  • How many are installed?

  • 5 amp round pin plug fitted

  • 5 amp socket labelled: 'Plinth lighting'

  • 13 amp plug fitted

  • 13 amp socket fitted

Under socket lights

  • SELV version

  • Driver installed under plinth

  • Cables secured

  • Blue plug fitted

  • 240 V version

  • Blue plug fitted

  • Cables secured under plinth

Sockets

All socket types

  • USB in correct places

  • Shaver socket > 600mm from

  • shower / bath

  • Polarity correct

  • > 3000mm from bath / hot tub

Alarms

Smoke alarm

  • > 300mm from detectors and remote bases

  • Mains detectors- Optical type

  • Mains detectors- ionisation type

  • Heat detector

  • Remote bases

Carbon detector

  • Carbon detector installed

  • Between 1000m and 3000mm of appliance

  • Dedicated detector for Morso / Solid fuel lounge burner

Boilers

All boiler types

  • Thermostat connected correctly

  • Boiler wired in

  • Wireless room thermostat fitted

  • 3 amp fused fitted

  • Time clock fitted

  • Thermostat link cable removed from boiler

Electric boiler

  • Fitted

  • 3 amp fuse fitted

  • Control’s isolator labelled

  • Wireless thermostat installed

  • Wireless control box fitted and wired into boiler

  • Warning notice / 9kW notice attached to boiler with low tack tape

Bonding

Bonding

  • Water bonded

  • Gas bonded

  • Chassis bonded

  • Earth tags at all locations

Lamps

All lamps

  • All lamps match specification

  • Golf ball lamps fitted to alabaster

  • Golf ball lamps fitted to bulkheads

  • Dimmable lamps fitted to dimmer lights

  • Non-dimmable lamps fitted to non-dimmer lights

Consumer unit

Documents / labels

  • Next inspection label fitted

  • RCD test interval label fitted

  • Smoke detector label fitted

  • Certificate affixed to the consumer unit

  • Internally fire sealed

  • All blanks fitted

  • A PDF copy of this document to be affixed to the consumer unit

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.