Precast

  • Panels installed today:

  • Panel joints/brick joints are vertically plumb and in line<br>

  • Panel joints/brick joints are horizontally in line and true to grid

  • Window, door, and MEP rough openings are correct in size and location

  • Any "site" adjustments made today (note below and attach photos)

  • Inspections (note below any issues and attach photos)

  • All panels are secured before leaving at night

  • Panels are installed today are free of damage

  • Rope weeps are installed under loose granite sills (Gresser)

  • Additional notes

Curtain Wall

  • Interclad QC sign off on openings prior to setting frames

  • All precast caulking required at heads and sills for frame installation is complete

  • Frames installed today

  • Horizontal, vertical, and interior alignment appear consistent and correct

  • Frames and glass appear to be without damage

  • Interior sill and stool trim protective covering is installed

  • MB-2/MB-3 is installed at 1st floor window sill locations and terminated properly. End dams are present at jamb conditions.

  • All frames and glass have been secured prior to leaving for the night

  • Swing stages are secure for the night

  • Inspections (note below any issues/attach photos)

  • Additional Notes

Caulking

  • General areas caulked today

  • All joints are cleaned and primed

  • Correct caulk color is being installed

  • Joints are tooled smoothly and uniformly

  • Any excess caulk is wiped clean from adjacent surfaces

  • Weep systems/baffles are clear of caulking

  • Swing stages are secure at the end of each day

  • Additional notes

Metal Panels

  • Vapor/Air barrier is properly installed and sealed to substrate prior to metal panel installation beginning

  • Metal panels are free of scratches, dings, dents.

  • Weeps and baffles are present and installed properly

Insulation/Vapor Barrier

  • FSK tape has 1" loop at curtain wall head<br>

  • Gutter/drainage channels and weep tubes are clear of debris prior installing FSK insulation

  • Vapor barrier is properly terminated at 1st and 2nd floor precast column enclosures around building perimeter

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.