Quality Assurance<br>Report
-
Address
-
External auditor
-
Auditors number/reference/type
-
BK reference number
-
Site
-
Property location
-
Customer name
-
Date of audit
-
QA auditor
Contractor
-
Installers name
-
Measure name/type
-
Work/handover date
Quality Assurance<br>Report
Loft
-
Loft - No insulation on loft hatch
-
Loft - No Photographic evidence
-
Loft - Electric Cable is covered by installation
-
Loft - No draught proofing installed
-
Loft - Ventilation not sufficient
-
Loft - Loft Insulation does not meet minimum building regulations
-
Loft - Downlights are not covered in the loft space
-
Loft - Documents
Solar
-
Solar - Solar PV Schematic not present
-
Solar - The exterior run of cable down the side elevation is not secured to the wall
-
Solar - Installer Missing Documents
-
Solar - Missing Photographic evidence
-
Solar - Post install Missing Documentation
-
Solar - Walkboard by inverter not present
-
Solar - Issue with panels install
CWI
-
CWI - Injection holes/penetrations have not been sealed
-
CWI - No background ventilation present
-
CWI - Missing documents
-
CWI - Combustion appliances
-
CWI - Approval for U-Values is missing
-
CWI - Drill pattern
Ventilation
-
Ventilation - Background ventilation
-
Ventilation - No evidence that the extractor fans fitted correctly
-
Ventilation - MEV's not present
-
Ventilation - Trickle vents not present
-
Ventilation - Undercuts not present
-
Ventilation - Does not match Vents strategy
-
Ventilation - Missing Photo evidence
-
Ventilation - Missing documentation
-
Ventilation - Minor works certificate required for ventilation installation
ESH
-
ESH - Electrical Cables not clipped away from pipework
-
ESH - Missing photographic evidence
-
ESH - Missing paperwork
Boiler
-
Boiler - Boiler flue location
-
Boiler - Damage caused by installers
-
Boiler - System not working
-
Boiler - Not installed to up to date regulation standard
-
Boiler - Issue with Radbots and TRV's installed
-
Boiler - Missing Paperwork
-
Boiler - Missing Photographic evidence
-
Boiler - Issue with radiators
-
Boiler - pressure drops out
ASHP
-
ASHP - System regularly dropping in pressure
-
ASHP - System trips out daily
-
ASHP - not installed to manufacturers instructions and other guidance
-
ASHP - Does not match the strategy
-
ASHP - Discharge pipe not terminated in accordance with Building Regulations
RIR
-
RIR - No dataplate photo supplied
IWI
-
IWI - Do any faults specific to the measure installed present an immediate risk to the occupier or the property?
-
IWI - Do you believe that there are any other safety related issues with the installation?
-
IWI - Have all avoidable thermal bridges/heat loss areas which could have been insulated, been insulated?
-
IWI - Has 100% of the measure been installed where possible?
-
IWI - Is the measure installed as specified in the appropriate product certificate and/or system designer's instructions?
-
IWI - Is the insulation sealed around all adjoining boards, walls, ceilings and floors?
-
IWI - Is the insulation continued 400mm along all party and solid partition walls where required by the system design?
-
IWI - Have all services (e.g. light switches, sockets, radiators) been removed, insulated behind and re-positioned inside the heat<br>loss area?
-
IWI - Has the system been sealed fully at edges, corners and junctions to prevent the ingress of moisture?
-
IWI - If wet room(s) have been omitted do they have a safe heating system that can achieve a minimum of 18 degrees C ?
-
IWI - If wet room(s) have been omitted, has CONTINUOUS extract ventilation been installed?
-
IWI - Is the external condition of the property suitable for IWI to be installed?
-
IWI - Does the provision of ventilation in the property meet the requirements of the relevant version of<br>PAS?
-
IWI - Is background ventilation present in each habitable room (e.g. trickle vents / room ventilators)?
-
IWI - Is the ventilation in all habitable rooms controllable?
-
IWI - Are background ventilators at least 1700mm above floor level, to reduce cold draughts, but still easy for the occupant to reach?
-
IWI - Are mechanical extract ventilators intermittent or continuous?
-
IWI - Do background ventilators have a minimum equivalent area of 4000mm2 and are not present in wet rooms?
EWI
-
EWI - Roof overhand not installed correctly
-
EWI - Installation of EWI carried out to an acceptable standard
-
EWI - The system has not been sealed and is watertight
-
EWI - Movement/Construction Joints
-
EWI - Building features re-instated