A10-FOUNDATIONS INSPECTION CHECK LIST
-
SETTLEMENT & Alignment ISSUES
- Soil Changes in load bearing
- Shrinkage
- Erosion or compaction
- Adjacent construction issues
- Reduced soil cover resulting exposure
- Building equipment load vs Design load issues
- Vibration from building equipment
- Structural or occupancy changes
- Inadequate bearing capacity
- Foundation settling
- Earthquake resistance non functioning
-
Add media
-
MOISTURE PENETRATION
- Water table changes
- Inadequate drainage
- Ineffective drains/sump pumps/sump pits
- Roof drainage/storm sewer connections
- Roof drain restrictions/gutters/downspouts
- Surface drainage slope issues
- Utilities -broken or improper functioning
- Leakages- wall cracks/expansion, construction joints
- Inadequate or defective water proofing
- Condensation/inadequate ventilation
- Inadequate vapour barrier/dehumidification
-
Add media
-
TEMPERATURE CHANAGES
- Insulation issues
- improperly selected insulation values
- Fire rating
- Vermin resistance
-
Add media
-
Surface Material Deteriorations
- Concrete/masonry/stucco/spalling
- Corrosion of reinforcing
- Moisture penetrations
- Chemical reaction
- Corrosion damage on steel or other ferrous materials
- Corrosion due to contact with acid bearing soils
- Wood decay due to moisture or insect infestation
-
Add media
-
OPENEINGS DETORIATION
- Non functioning of doors/windows/hatchways/stairways
- Utilities penetrations damage due to weather/wear
- Other damages
-
Add media
-
FLOORS, concrete Cracking or arching
- Shrinkage or settlement of subsoil
- Inadequate drainage
- movement in exterior walls
- Improper compaction of base
- Erosion of base
- Heaving from hydraulic pressure
-
Add media
-
Floors/Wood-Rotting or arching
- Excessive dampness
- Insect infestation
- Leak in building exterior
- Lack of ventilation
-
Add media
-
CRAWL SPACE VENTILATION AND MAINTENANCE
- Inadequate air circulation due to blockage of openings in foundation walls
- Moisture barrier ineffective
- Pest control issues
- Poor house keeping
- Improper drainage
-
Add media
B10-SUPERSTRUCTURE INSPECTION CHECK LIST (CONCRETE-COLUMNS,WALLS AND FLOOR AND ROOF SLABS)
-
OVERALL ALINGMENT
- Settlement issues
- Design faualt
- Improper fabrication
-
Add media
-
DEFELECTION
- Expansion issues
- Contraction issues
-
Add media
-
SURFACE CONDITIONS -CRACKS
- Inadequate design
- Changes in design loads
- Stress concentrations
- Extreme temperature changes
-
Add media
-
SCALING, SPALLAS AND POP OUTS
- Extreme temperature changes
- Reinforcement corrossion
- Environmental conditions
- Mechanical damages
- Poor material
-
Add media
-
STAINS
- Chemical reaction of reinforcing
- Reaction of material in concrete mixture
- Environmental condition
-
Add media
-
EXPOSED REINFORCING
- Corrosion of steel
- Insufficient cover
- Mechanical Damge
-
Add media
-
STEEL (STRUCTURAL MEMBERS, STAIRS AND CONNECTIONS)-OVER ALL ALINGMENT
- Settlement issues
- Design issues
- improper fabrication
-
Add media
-
DEFLECTIONS OR CRACKING
- Expansion issues
- Contraction issues
- Changes in design loads
- Fatigue due to vibration or impact
-
Add media
-
CORROSION
- Electrochemical reaction
- Failure of protective coating
- Excessive moisture exposure
-
Add media
-
SURFACE DETERIORATION
- Excessive wear and tear
-
Add media
-
WOOD (STRUCTURAL MEMBERS AND CONNECTIONS) -OVER ALL ALINGNMENT
- settlement issues
- Design issues
- Construction issues
-
Add media
-
DEFLECTION OR CRACKING
- Expansion issues
- Contraction issues
- Changes in design loads
- Fatigue due to vibration or impact
- Failure of compression members
- Poor construction
- General material failure
-
Add media
-
Rot (Decay)
- Direct contact with moisture
- Condensation
- Omission or deterioration of vapor barrier
- Poor construction
- Damage from rodents or insects
-
Add media
B20-EXTERIOR CLOSURE INSPECTION CHECK LIST 1. General Inspections 2. Overall apprearence 3. Displacement 4. Paint Condition 5. Caulking 6. Window and door fit 7. Flashing conditions 8. Material integrity 9. Cracks 10. Evidence of moisture 11. Construction Joints 12. Hardware condition
-
General Inspection
- Yes
- No
- N/A
-
Add media
-
Exterior Walls
-
Add media
-
Wood (Shingles, weatherboard,sidings,plywood) Paint or surface treatment condition Rot or decay
- paint or surface treatnment conditions
- moisture pentration
- Rot or decay
- loose cracked, warped or broken boards and shingles
-
Add media
-
Concrete, Masonry, and tiles (Concrete, bricks, concrete masonry units, structural tiles, glazed tiles,stucco,stone)
- settlement
- structural frame movement casing cracks
- construction and expansion joints
- condition of caulking and mortar
- surface deteriation
- efflorescence and staining
- parapet movement
- tighteness of fastners
-
Add media
-
Metal (Corrugated iron or steel, aluminium,enamel coated steel,protected metals )
- settlement
- structural frame movement
- condition of bracing
- surface damage due to impact
- tighteness of fasteners
- caulking
- flashings
- corrossion
-
Add media
-
Finishes (mineral products,fiber glasses,polyester resins,and plastics)
- settlement
- structural frame movement
- surface damage due to impact
- cracks
- stains
- fastners
- adhesion to substrate
- caulking
- flashings
- lead paint
- asbestos products
-
Add media
-
STAINS
- Yes
- No
- N/A
-
Add media
-
Insulation
- insulation present
- satisfactory condition
-
Add media
-
Windows & Doors
- frame fitting
- frame and molding condition
- paint or surface finish
- putty and weather stripping
- hardware and operating parts
- security
- cleanliness
- material condition (glasses,wood,and metal panels)
- rot or corrossion
- screens and storm windows
-
Add media
-
Shading Device
- material condition
- operations
- cleanliness
-
Add media
B30-EXTERIOR CLOSURE INSPECTION CHECK LIST 1. General Inspections 2. Overall apprearence 3. Displacement 4. Paint Condition 5. Caulking 6. Window and door fit 7. Flashing conditions 8. Material integrity 9. Cracks 10. Evidence of moisture 11. Construction Joints 12. Hardware condition
-
General Appearence
-
Add media
-
Water Tightness
- evidence of leaks on undersurfacs
- surface weathering
- faulty material
- faulty design
- faulty application
- standing water
- weather damage
- mechanical damage
- fastening failure
- flashing failure
-
Add media
-
Roofing Surface-Built up (felt or bitumen surfacing)
- Adhesion
- moisture meter reading
- bare areas
- Blisters,wrinkles
- cracks, holes,tears
- fish mouths
- alligatoring
- ballast
-
Add media
-
Single ply (Thermosetting, thermo plastic,composites)
- Adhesion
- moisture meter reading
- bare areas
- blisters, wrinkles
- cracks
- holes,tears
- seam conditions
- protective coating
- Ballast
-
Add media
-
Metal roofing (preformed,formed)
- corrosion (%)
- protective coating
- seams
- cracks or breaks
- holes
- expansion joints
-
Add media
-
Shingles & tiles (metal, clay, mission, concrete or others)
- disintegration
- broken or cracked (%)
- missing(%)
- fastners
- underlayment
-
Add media
-
Wood shingles
- Yes
- No
- N/A
-
Add media
-
Insulation
- Full coverage (%)
- full thickness (%)
- satisfactpory conditions
-
Add media
-
Roof Penetrations
- Weather tightness
- operables
-
Add media
-
Flashings
- deterioratioon
- open joints
- holes or damage
- anchoring
- ptrotective coating
-
Add media
-
Drainage
- alignment
- free flowing
- clamping rings secure
- screens
- corrosion
-
Add media
C10-PART IONS AND DOORS INSPECTION CHECK LIST
-
General Inspection
- strength and stability
- physical condition
- acoustical quality
- adaptablity
- maintainablity
- code compliance
-
Add media
-
Wall Material
- carcks
- settlement
- holes
- defective material
- looseness
- operational abuse or vibration
- missing segments
- enviornomental attack
- water stains
- moisture
- joints
- structural expansion of contraction
- surface appearance
- wind pressure
-
Add media
-
Hardware
- overall conditions
- appearance
- keying system
- operations
- fit
- lock sets
- cylinders
- panic devices
- mainatanablity
- security operations
-
Add media
C-30 WALLS AND FINISHES INSPECTION CHECK LIST
-
General Inspection
- Good
- Fair
- Poor
- evidence of moisture
- settlement
- cracks
- surface conditions
- cleanliness
- stains
- discolorations
-
Add media
-
Paint
- repainting necessary
- peeling, cracking,flaking
- reflectivity
- maintainablity
-
Add media
-
Covering & Coatings
- Yes
- No
- N/A
-
Add media
-
Interior Glazing
- cracks
- seals
- frame conditions
- missing panes
- shading devices
-
Add media
C-40 FLOORS AND FINISHES INSPECTION CHECK LIST
-
General Appearence
- Good
- Fair
- Poor
- Evidence of moisture
- Visible settlement
- Irregular surface
- Tripping Hazards
- Handicapped hazards
- Replacement necessary
-
Add media
-
Carpet (Tufted, Tiled)
- Age
- Excessive wear
- Stains
- Discoloration
- Holes,tears
- Seam conditions
-
Add media
-
Resilient (Asphalt Tile, Cork Tile,Linoleum,Rubber,Vinyl)
- Broken tiles
- Loose tiles
- Shrinkage
- Lifting, cupping
- Fading
- cuts,holes
- Porosity
- Asbestos present
-
Add media
-
Masonry (Stone & Brick)
- Cracks
- Deterioration
- joints
- Stains
- Porosity
- Sealing
-
Add media
-
Monolithic Topping (Concrete, Granolythic, Terrazzo,Magnesite)
- Cracks
- Porosity
- joints
- Sealing
-
Add media
-
Wood (Plank,Strips, Block,Paraquet)
- Shrinkage
- cupping, warpage
- Excessive wear
- Unevenness
- Decay
- Sealing
-
Add media
C-50 CELINGS AND FINISHES INSPECTION CHECK LIST
-
General Inspections- Overall Apperance
- Good
- Fair
- Poor
- settlement or snagging
- alignment
- attachment
- evidence of moisture
- stains and discoloration
- missing units
- suitablity
- acoustic quality
- code compliance
-
Add media
-
Exposed Systems (Un painted, Painted,spray-on,decorative)
- Cracks
- surface deteriorations
- missing elements
- adhesion
-
Add media
-
Applied to Structure and Suspended
- Good
- Fair
- Poor
- Fastners
- trim condition
- Openings Panel
- Inserts
- lighting fixtures
- air distirbution
- fire protections
- Others
-
Add media
D-10 Conveying Inspection Check List (Elevators & Escalators)
-
Genreal Inspection
-
Add media
-
Over all Appearance (Interior)
-
Add media
-
Over all Appearance (Exterior)
-
Add media
-
Maintenance History
- Regular inspection frequency
- door operation
- control systems
- Noise
- code compliance
- handicapped access
- major repairs necessary
- replacment necessary
-
Add media
D-20 MECHANICAL/PLUMBING INSPECTION CHECK LIST
-
General Appearance
- Good
- Fair
- Poor
- Leaks,dripping,running faucets and valves
- Maintenance history
- supply adequacy
- sanitation hazards
- drain and waste connection
- backflow protection
- cross connections'
- fixture quatity
- fixture types and conduits
- handicapped fitures
- female facilities
- metal pipe & fitting corrosion
- Pipe joints and sealing
- pipe insulation
- hanger supports & clamps
- Filters
- Building user comments
-
Add media
-
Water System
- water pressure adequate
- odors,tastes
- Main cut off operable
- water heating temperature setting
- pump condition
- insulation condition
-
Add media
-
Sanitary
- flow adequate
- cleanout access
- floor drains
- chemical resistance
- gradient
- onsite disposal system
-
Add media
-
Storm System
- flow adequate
- cleanout access
- floor drains
- chemical resistance
- gradient
- onsite disposal system
-
Add media
-
Code Requirement
- Good
- Fair
- Poor
- Code requirements
- EPA/Local Permits
- Others if any
-
Add media
-
Fire Protection System
- Regular inspection
- sprinkler heads operable
- complies with local regulation and code
- controls operable
- Hose cabinets functional
- water pressure sufficinet
-
Add media
D-30 MECHANICAL/HVAC INSPECTION CHECK LIST
-
General Inspection
-
Add media
-
Lubrication: Bearings & Moving Parts
-
Add media
-
Rust & Corrossion
-
Add media
-
Motors,Fans,Drive,Assemblies
-
Add media
-
Pumps
-
Add media
-
Wiring & Electrical Controls
-
Add media
-
Thermostats and Automatic Temperature Controls
-
Add media
-
Thermal Insulation & Protective Coatings
-
Add media
-
Guards, Casings,Hangers,Supports,Plat Forms &Mounting Bolts
-
Add media
-
Piping System Identification
-
Add media
-
Strainers
-
Add media
-
Solenoid Valves
-
Add media
-
Water Sprayers,weirs,and similar devices
-
Add media
-
Air Cooled Condensers
-
Add media
-
Compressors
- Good
- Fair
- Poor
-
Add media
-
Liquid Receivers
-
Add media
-
Refrigerant Driers, Strainers,Valves, Oil Traps & Accessories
-
Add media
-
Building User Comments
-
Add media
-
Cleaning, Maintenance, Repair & Replacement
- Registers
- Grills
- Dampers
- Draft diverters
- Plenum chambers
- Supply & return ducts
- Louvers
- Fire dampers
-
Add media
-
Air Filters
- Good
- Fair
- Poor
- Correct Type
- Replacement Schedule
-
Add media
-
Coolig System Evaluation
- Cooling capacity
- Temperature
- cooling all seasons
- Noise level
- Energy Consumption
- Air Circulation
- Filteration
- Reliablity
-
Add media
-
Ventilation System Evalation
- air velocity
- exhaust air system
- bag collection
- wet collectors
- steam and hot water coils
- Electrical heating system
- fire hazards
- fire protective devices
-
Add media
D-30 MECHANICAL/HVAC INSPECTION CHECK LIST
-
General Inspection
-
Add media
-
Lubrication: Bearings & Moving Parts
-
Add media
-
Rust & Corrossion
-
Add media
-
Motors,Fans,Drive,Assemblies
-
Add media
-
Pumps
-
Add media
-
Wiring & Electrical Controls
-
Add media
-
Thermostats and Automatic Temperature Controls
-
Add media
-
Thermal Insulation & Protective Coatings
-
Add media
D-50 ELECTRICAL SERVICE & DISTRIBUTION. INSPECTION CHECK LIST
-
General Inspection
- Good
- Fair
- Poor
- Safety conditions
- Service capacity, % used & age
- Switchgear capacity, % used $ age
- Feeder capacity, % used & age
- Panel capacity
- Thermo-scanning
- Mainteanance records available
- Convenience outlets
- Building user comments
-
Add media
-
Exterior Service
- Line drawing
- Feed source:
- Utility/owned
- Above/below ground
- Transformer
- Transformer tested
- Transformer arcing or burning
- Transformer PCB'S
- Ownership(facility or utility)
-
Add media
-
Interior Distribution System
- Line Drawing
- Incoming conduit marked
- Main circuit braker marked
- Panel boards, junction boxes covered
- All wiring In conduit
- Conduit properly secured
- Panels marked
- Panel schedules
- Missing breakers
-
Add media
-
Emergency Circuits
- Emergency generators
- Condition & age
- Auto start & switchover
- Testing schedule
- Test records available
- Service schedule
- Service Schedule records available
- Circuits appropriate
- Cooling & exhaust
- Fuel storage (capacity)
-
Add media
-
Emergency Lighting & Power Systems
- Battery operation
- Seprate power feed
- Exit signs
- Stairways/corridors
- Elevators
- Interior areas
- HVAC
- Exterior
-
Add media
G-20 SITE WORK INSPECTION CHECK LIST
-
General Inspection
- Overall apperanceOverall apperance
- Good
- Fair
- Poor
- Maintainability
- Repairs/replacements
- Code compliance
-
Add media
-
Roads, Walks & Parking Lots
-
Add media
-
Curbing
- Alignment
- Erosion
- Repairs &Replacement
-
Add media
-
Drainage & Erosion Controls
- Surface drainage
- Manholes, catch basins
- Vegetation
- Channels,dikes
- Retention, detention
- Drains
-
Add media
-
Parking Lot Controls
- Location
- Operation
- Repairs/replacements
-
Add media
H-10 SAFETY INSPECTION CHECKLIST
-
General Inspection
- Good
- Fair
- Poor
- Code compliance
- Maintainability
- Means of egress
- Fire ratings
- Audible & visual device condition
- Extinguishing systems(see also D20 mechanical/plumbing)
- Lighting system(see also D50 Electrical Lighting/poweer)
- Handicapped accessibility
-
Add media
-
Exterior Lighting
- Good
- Fair
- Poor
- Adequacy
- Condition
- Controls (type & locations)
-
Add media
-
Fire Alarm Systems
- Panel visible
- Operational
- Pull station condition
- Detector conditions
-
Add media
-
Stairs & Ramps
- Exits marked
- Hardware operational
- Tripping hazard
- Surface conditions
- Lighting adequate
- Handrails
-
Add media