Title Page
-
Conducted on
-
Prepared by
-
Location
Property Information
-
Photo of Property
Bathroom - Required Plumbing Facilities, Electrical and Ventilation
-
Does every unit have a tub or shower?
-
Does every unit have a water closet (toilet)?
-
Does every unit have a lavatory?
-
Are bathroom plumbing fixtures and systems being maintained and in working order?
-
Do bathroom plumbing systems and fixtures have adequate clearances as required by code?
-
Are bathroom plumbing systems and fixtures properly vented? (Not cross connected, or otherwise not installed per code.)
-
Are bathroom receptacles GFCI protected?
-
Do bathrooms have an openable window or a mechanical vent to vent directly to the outside?
Kitchen - Required Plumbing Facilities, Electrical and Ventilation
-
Does every unit have a kitchen sink?
-
Are kitchen plumbing fixtures being maintained and in working order?
-
Do kitchen plumbing fixtures have adequate clearances as required by code?
-
Are kitchen systems properly vented? (Not cross connected, or otherwise not installed per code.)
-
Are kitchen receptacles GFCI protected?
Water System
-
Is hot water provided at 110 degrees?
Heating Facilities
-
Is the system able to maintain the home at 65 degrees?
Mechanical Equipment
-
Is all fuel burning equipment connected to an approved chimney or vent?
-
Is supply air provided as required by the manufacturer?
-
Are all clearances to combustible material being maintained?
Electrical Facilities
-
Electrical service shall be 3-wire, 120/240 volt, single phase with 60 amp minimum and shall be readily accessible with no obstructions
-
Flexible cords shall not be used for permanent wiring or run through windows, doors, walls, cabinets, floors or ceilings.
Electrical Equipment
-
Does every habitable space have at least two or more receptacles?
-
Does every receptacle have a proper cover?
-
Does every laundry room have one ground receptacle?
Means of Egress
-
Path of travel shall be maintained free of obstructions.
-
Doors within paths of travel shall not be locked except by the door hardware.
-
Emergency escape openings shall be maintained in operable conditions.
Fire Protection System
-
Are fire alarms in sleeping areas operable as required by code in effect at time of building construction?
-
Are carbon monoxide detectors installed? (required if gas appliances or attached garage is present.)
Light and Ventilation
-
Does every habitable room have one openable window sized at least 8% of the floor area?
-
Is 45% of each of the windows glazed area openable?
-
Is dryer on its own vent system and vented to the outside?
Interior Structures
-
In the structure maintained in sanitary condition?
-
Loads are not exceeded for floors, roofs, and other structural members.
-
Interior surfaces are not decayed and are properly finished.
-
No evidence of leaks in roof found.
-
Are stairs and handrails securely anchored and in good condition?
-
Are windows operable (when required) and weather-tight and lockable?
-
Are doors operable and lockable and in good repair?
Exterior Property Areas
-
Is grass height less than 12"?
-
Is drainage directed away from the structure?
-
Are walkways firm and stable?
-
Are all vehicles on site licensed and operable?
-
Are vehicles and trailers located on a permitted driveway? (Accessory Living Units must have four stabilized parking spaces on site.)
-
Are accessory structures sound?
Exterior Structures
-
Loads are not exceeded for floors, roofs, and other structural members.
-
Exterior surfaces are not decayed and are properly finished.
-
Property address is visible with 4" numbers to be seen from street at night.
-
No evidence of leaks in roof.
-
Stairs and handrails are securely anchored and in good condition.
-
Windows are operable (when required) and weather-tight.
-
Doors are operable and lockable and in good repair.
Handrails and Guardrails
-
Are handrails/guardrails present on a least one side for any stair that is over four risers?
Rubbish and Garbage
-
Do any unused refrigerators have doors removed?
-
Is garbage being placed in garbage cans and being removed from property as needed?
Occupancy Limitations
-
Habitable rooms are at least 7' wide in any direction.
-
Every bedroom is at least 70 square feet or 50 square feet per bedroom occupant.
-
Kitchens have a minimum of 3' passage.
-
Minimum ceiling height is 7' (with exceptions).
-
Every living room is at least 120 square feet.
-
Bedrooms are not the only means to exit other rooms.
Report Complete
-
Completion Time:
-