Information
-
TOW Number
-
FDH Location
-
FSAM Location
-
Conducted on
-
Prepared by (your name)
-
Installation completed by:
-
Customer Address
Preliminary checks
-
DBYD required/conducted
-
Way leave access consent required/obtained
-
Land access consent required/obtained
Pit & conduit installation
-
Conforms to slope and ground level
-
The top rim of the lid is not warped or bent and is labelled as a communications pit
-
Pit not located within a carriageway, driveway, 3m of a pole or 5m of a corner
-
Pit positioned with long side parallel to the adjacent property, boundary or road way
-
The pit does not have exposed edges
-
Correct service drop access pit used (length 650mm x width 280mm x depth 565mm)
-
Pit lid has a lifting tool hole at each end of the lid
-
Pit has a gasket fitted
-
Radial clearance of 300mm from gas pipe over 110mm diameter
-
Radial clearance of 150mm from gas pipe under 110mm diameter
-
Radial clearance of 300mm from high voltage
-
Radial clearance of 100mm from low voltage
-
Radial clearance of 300mm from high pressure water main
-
Radial clearance of 150mm from local water reticulate on
-
Radial clearance of 300mm from mains sewerage
-
Radial clearance of 150mm from local sewerage connection
-
Radial clearance of 100mm. From other telecommunications
-
Conduit installed a minimum of 50mm from the pit floor
-
25mm separation between conduits
-
Conduit has bushes fitted and finishes square and flush with the pit end wall
-
Conduit depth is 400mm with warning tape at 300mm
-
Conduit shall be white PVC-U 23mm diameter
-
Work area left clean and tidy
Underground Drop Cables
-
Cables connected to the correct Multiport port
-
Correctly labelled
-
Cable slack is coiled neatly
-
Ground reinstatement undertaken
-
Cable or conduit has been suitably fixed to the premises
-
Telstra LIC used
-
Work area left clean and tidy
PCD
-
Installed at the closest practical point on the premise to connect drop
-
Meets power source separation requirement of 1000mm
-
Meets water and gas fitting separation requirements of 250mm
-
Meets distance from corner of wall requirements of 150mm
-
Meets distance from window or balcony requirement of 150mm
-
Mounted vertically with latches on the right hand side
-
PCD height must fulfil all location and accessibility req's from NBN-NO-GDE-0007
-
Drop cable enters only from bottom of the PCD
-
25mm gap has been left between the lead-in pipe and the PCD (for underground drop)
-
Cables go through the correct grommet type (flat=Left, round=Centre or right)
-
One cable per Entry/Exit point
-
Sufficient space to access the PCD and open the latches and door
-
Stored cable is not excessive (<=3m drop, <5m Premises)
-
Store cable is coiled neatly without exceeding bend radius
-
Work area left clean and tidy
-
Reinstatement
-
PCD
-
Pit