Information
-
TOW Number
-
FDH Location
-
FSAM Location
-
Conducted on
-
Prepared by (your name)
-
Installation completed by:
-
Customer Address
Premises Cable
-
Building enter point sealed with silicone
-
If cable is run down wall is it located next to down pipe, conduit or permanent fixture
-
Cable route minimises bends and excessive tension
-
Cable route is not subject to crushing pressures or sharp edges
-
Cable/conduit is secured every 500mm (max) to the wall, frame, floor bearers, truss, etc
NTD, PSU & FWO
-
FWO, NTD & PSU have a minimum clearance of 30mm on all sides
-
FWO minimum clearance of 100mm from floor (above skirting board)
-
FWO has a laser safety label affixed on the cover
-
FWO cabling has no inappropriate bends or excessive tension
-
NTD & PSU mounted height between 800-1700mm to the top of the device
-
NTD & PSU not installed where ambient temperature is routinely < 10*c or 40*c
-
NTD & PSU within 1.5m of a 240V GPO
-
NTD & PSU easily accessible
-
NTD within 5m of the FWO
-
NTD within 3m of the PSU
-
NTD labelled at back of unit with serial number & laser/power safety warnings
-
NTD labelled at front with ID number
-
NTD patch cable run neatly with no inappropriate bends or excessive tension
-
PSU within 15m of an outdoor NTD
-
PSU supplied by 240V GPO with no other devices e.g. Double adaptor or power board
-
PSU 3x labels - Warning (cover), indicator/Button (inside cover), ID no's (Bottom RH side)
-
PSU not installed in confined area with restricted air circulation
-
PSU not located within 1.5m of a water or space heater
-
External NTD has a separate 6mm2(min) earth lead run to the premises earth stake
-
Units mounted securely
-
Work area left clean and tidy
FDH
-
Correct splitter tail patched
-
Correct local port patched
-
Connectors cleaned
-
Patch cable run and looped neatly
-
Termination field updated in 0.4 fine tip permanent marker
-
Work area left clean and tidy
-
Completed Installation