Title Page
-
Site Name
-
Customer ID
-
Site Location
-
Premise Type
- SDU (Single Dwelling Unit)
- 2-4 Homes
- 5-8 Homes
- 9-12 Homes
- 5-12 Homes Front Units Only
- 5-12 Homes Long Linear Front Units Only
-
Portfolio Name
-
Portfolio name
-
State site name
-
Installation completed by
-
Pre-install completed by
-
Engineer Name
-
Lead-in Customer install completed by
-
Engineer Name
-
Contractor Team at time of Installation
-
Contractor name
-
FTM name
-
FTM's Name
-
Auditing Compliance Officer
-
Conducted on
-
Compliance Region
- Scotland
- Birmingham to Borders
- London North (M4 corridor), South Wales
- London South, Kent & Southwest
Audit Log
Audit Information
-
All categories and items marked within in this report have been carried out in accordance with the Customer Connection HyperZone Installation Post Audit (UG Cabling)audit procedural document v1.0
Underground Cabling
-
Compliance Status
Failed Sample
-
Location
-
Node ID
-
UG Cabling Compliance Fail
- PIA00 Cable ties have been left with sharp edges
- PIA05 Cabling restricting all chamber access & egress.
- PIA06 Cabling restricting all access to other line plant
- PIA06 Cabling entangled with other line plant
- PIA03 No PIA label present
- PIA04 No information present on the label.
- PIA04 Label missing operator ID.
- PIA04 Label missing PIA reference number.
- PIA04 Information on the label not legible
- PIA07 - Fixing kit 1A missing or not used to secure node/cable
- HYPUG101 Cables egressing the node are not protected
-
Engineer Remediation Notes
-
Evidence Of Remediation
-
The remediation is completed up to standard
-
Supporting Evidence & Notes
Capping & Containment
-
Compliance status
Failed Samples
-
Location
-
Capping & Containment Compliance fail
- HYPCAP101 - Capping is loose
- HYPCON101 - Use of existing containment is not in line with the proposal
- HYPCON109 - Cabling within PVC trunking is not secured using non-combustible fixings
- HYPCON110 - Non-combustible fixings are not present at intervals of 0.5m, or less in communal/exposed areas within PVC trunking
- HYPCON111 - Non-combustible fixings are not present at intervals of 1m, or less in non-exposed areas within PVC trunking
-
Engineer Remediation Notes
-
Evidence Of Remediation
-
The remediation is completed up to standard
-
Supporting Evidence & Notes
Distribution Point (Covers CSP'S & Wall-boxes)
-
Compliance status
Failed Samples
-
Location
-
Distribution point Compliance Fail
- HYPDP102 - Distribution point does not contain the correct fixings in line with Hyperoptic standards
- HYPDP104 - The distribution point is loose and unstable
- HYPDP105 - Distribution point cover is missing
- HYPDP107 - Distribution point is not security locked in line with Hyperoptic standards
- HYPDP108 - Grommet seals are not present where cabling enters the wall box
- HYPDP109 - Comb retention kit not present (MMR wall box only)
- HYPDP110 - Cable strain relief devices not present (SMDU wall box only)
-
Engineer Remediation Notes
-
Evidence Of Remediation
-
The remediation is completed up to standard
Cabling
-
Compliance status
Failed Samples
-
Location
-
Cabling Compliance fail
- HYPKX101 - Drop Cable exiting PIA capping or Lead in Duct is not protected by Kopex to the underside of the CSP
- HYPKX102 - Cable installed below 150mm in high pedestrian traffic area is not protected by Kopex
- HYPC104 - Catenary wire is not supported at intervals of 5m or less
- HYPC109 - Cable installation not in line with the proposal (Only applicable to installs supported by DSS)
- HYPC110 - Cable left vulnerable
- HYPC111 - Cables are affixed to other service providers existing cables
-
Engineer Remediation Notes
-
Evidence Of Remediation
-
The remediation is completed up to standard
Fire Stopping (Only applicable internally to the premise)
-
Compliance status
Failed Samples
-
Location
-
Fire Stopping Compliance Fail
- HYPFS101 - Technical detail not followed in line with the method statement or manufacture data sheet
- HYPFS102 - No reinstatement has been made around the service
- HYPFS108 - Gaps are present around the service
- HYPFS103 - Mastic applied over existing foam product.
- HYPFS104 - Unauthorised penetration into existing batt system.
- HYPFS105 - Unauthorised use of existing aperture.
- HYPFS106 - Unauthorised penetration into fire mortar.
- HYPFS107 - Unauthorised cable route through existing building defect
- HYPFSID101 - No ID label present.
- HYPFSID102 - Information ID label not legible
- HYPFSID103 - • ID label not affixed to cable using cable ties.
-
Engineer Remediation Notes
-
Evidence Of Remediation
-
The remediation is completed up to standard
Weatherproofing
-
Compliance status
Failed Samples
-
Location
-
Weatherproofing Compliance Fail
- HYPWS101 - No weather seal present within the aperture.
- HYPWS102 - Degradable product used to seal the aperture.
- HYPWS103 - Gaps present in the seal.
- HYPWS104 - Brick repair kit not used on brick blowout
-
Engineer Remediation Notes
-
Evidence Of Remediation
-
The remediation is completed up to standard
Housekeeping
-
Compliance Status
Failed Sample
-
Location
-
Node ID
-
Houskeeping Compliance Fail
- PIA02 Fibre sharps/shards present in the chamber
- PIA02 Fibre sharps/shards present around chamber area
- PIA08 Chamber lid left raised causing a trip hazard.
- PIA08 Significant engineer waste within the chamber
- PIA08 Significant engineer waste around chamber area
- PIA18 Multiple loops of cable left within the chamber
- PIA18 Excessive cable length applied to joint
- HYPHK102 - Evidence of engineer damage present resulting from installation
-
Engineer Remediation Notes
-
Evidence Of Remediation
-
The remediation is completed up to standard
-
Supporting Evidence & Notes
Audit Sign Off
-
Audit Result
-
Field Compliance Officer Sign Off
-
Audit Closure Date
-
Audit Closure Date is the date that the audit is passed over to the relevant stakeholder, and all investigations into auditory items are completed. Note: This is not necessarily the date of the site/engineer visit
-
Has this audIt triggered remedial action(s)
-
As a result of non-compliance, a separate supplementary failed items report has been issued to the corresponding Infrastructure remediation owner for corrective action and closure via the documented JIRA process.
-
Remeditaion Owner (i.e. ADM/FTM/AFIM)
-
Site Lead for Remedial Work
-
Re-Inspecting Compliance Officer
-
Has the re-inspection triggered an escalation process
-
Has this audit recorded any advisories
Underground Cabling
-
Recorded Advisories
-
Advisory Images
Capping & Containment
-
Recorded Advisories
-
Advisory Images
Distribution Points (Covers CSP'S & Wall-boxes)
-
Recored Advisories
-
Advisory Images
Cabling
-
Recored Advisories
-
Advisory Images
Fire Stopping (Only applicable internally to the premise)
-
Recored Advisories
-
Advisory Images
Weatherproofing
-
Recored Advisories
-
Advisory Images
Housekeeping
-
Recorded Advisories
-
Advisory Images
Site Documentation
-
Recorded Advisories
-
Advisory Images