Title Page

  • Community

  • Lot Number(s)

  • Conducted on

  • Prepared by

  • Homeowner

  • Closing date/completion date

Checklist

LANDSCAPING

  • All Erosion BMPs removed

  • All plant material is alive

  • Drainage swales in place and draining water, no standing water

  • Irrigation working properly, test all zones, check coverage of all heads

  • Landscaping Beds are free of debris and are tight

  • Main sewer tap cleanout has concrete ring with lid installed

  • Minimum 6" clearance from top of slab to grade

  • No bare/dead spots in sod

  • No construction debris on neighboring lots

  • Pine straw in place, no bare spots

  • Review all selections and options for completion and accuracy

  • Sewer cleanouts are 4‐6" above grade if in a bed. Flush if in grass

  • Stoops and Patios have sufficient fall away from house

  • Sufficient fall away from house on all sides

  • Tags/Labels removed from plans

  • Temporary power pole has been removed

  • Termite Stations are in place

  • Water meter installed and set flush with grade, box/lid undamaged

  • Yard is rolled and doesn't have excessive ruts

EXTERIOR

  • All flatwork is pressure washed

  • All penetrations are caulked/sealed

  • All porch columns installed, plumb, painted, trim is level

  • All siding has 1" clearance off roof deck

  • All slide guards have been removed

  • All soffit and fascia are secure/undamaged

  • All window screens are in place and free of rips or loose screen

  • Attic/Dormer windows are locked

  • Attic/dormer windows have been painted black on inside, no framing visible from outside

  • Check roofing plan for crickets. Crickets should extend 2‐3" beyond outside corner

  • Confirm elevation on plan matches house (shutters, vents, brackets, etc)

  • Exhaust vent covers are on and flapper doors in place.

  • Exterior Door thresholds secure and painted

  • Exterior lighting installed, all bulbs working

  • Flashing installed over all doors, windows, and siding blocks

  • Gas piping is grounded

  • GFCI outlets are in place and function properly, test all.

  • Gutters secure and pitched correctly

  • Hardie homes are free of over cuts around windows/doors/blocking

  • Hose bibs secure, sealed to house, backflow preventers installed with set screw sheared off

  • House address numbers are installed on house and are level.

  • HVAC condensation line drains away form house, should terminate 2‐3" above grade

  • HVAC secondary drain is located above a window.

  • HVAC Units are level, secured to pad, pad is above grade

  • If eaves are fire rated, power vents are installed

  • Kickout flashing visible at all rake walls and protrudes beyond siding

  • Line set for HVAC is insulated with no rips

  • Mailbox installed, level, painted, secure

  • No damage or paint on porch shingles. Inspect from second story window

  • No debris/paint on roofs. Check for ladder damage at lower roofs

  • Pipe boots are in place. Nail holes and penetration are sealed.

  • Review all selections and options for completion and accuracy

  • Ridge vents in place and have shingle cap installed

  • Siding is secure and free of excessive bows.

  • Solid soffit in rakes and within 3 feet of any exhaust vent

  • Splash blocks in place at all down spouts

  • Spot check Hardie homes for installation of seam flashing

  • Vented soffit installed in eaves.

  • Vents are painted black.

  • Water heater operates properly. Set temperature to 120°F

  • Weather stripping in place.

GARAGE

  • # of Low volt feeds in panel are accounted for on exterior/interior of home (no covered outlets)

  • All circuits in kitchen should be GFCI and ARC Fault protected (purple)

  • All low volt wires have been terminated in panel

  • Amperage on A/C breaker should match amperage on exterior disconnect

  • Check all light switches for functionality. Light first. Fan second

  • Check for tripped breakers.

  • Electrical Low volt whip has been trimmed out and face plate installed

  • Electrical panel is labeled and legible.

  • Electrical panel is secure, all screws in place, no empty knockouts

  • Emergency contact label is in place

  • Energy sticker is in place

  • Floors have been pressure washed, control joints free of debris

  • Low volt panel cover installed and secure. Door opens/latches properly

  • Low volt panel is labeled.

  • No daylighting at garage doors

  • Opener bulbs are installed.

  • Opener owners/manual and remotes are in kitchen drawer

  • Overhead doors are operational

  • Paint label is in place

  • Review all selections and options for completion and accuracy

  • Safety sensors are aligned and no excessive/loose wiring

  • Switch plates are secure, level, screws aligned

  • Water shut off operates, escutcheons installed, line insulated, shut off tag in place

  • Windows are clean, operable, no scratches

FOYER

  • All Door hardware operates/locks smoothly

  • All hinge pins and screws are in place

  • All light bulbs working

  • Base board is free of bowing

  • Check all electrical outlets for functionality

  • Check all light switches for functionality

  • Check all light switches for functionality. Light first. Fan second

  • Check plan for tempered window locations

  • Compare number of supply vents in room to manual J

  • Door bell button is secure/level/lights up

  • Door bell transformer is in conspicuous location

  • Door Chime functions on push and release

  • Doors do not rub frame or floor, reveal is consistent

  • Flooring is free of defects. No squeaks

  • Front door has good paint finish. No chips or scratches

  • Hinge/base bump installed on all doors

  • HVAC registers are square, not over tightened, free of insulation

  • Review all selections and options for completion and accuracy

  • Smoke Detector in place. Activated. Dust cover removed. Test for operation

  • Switch plates are secure, level, screws aligned

  • Tops of door casings are caulked and painted

  • Window/door trim level, flush, good paint coverage, caulked well

  • Windows are clean, operable, no scratches

  • Wire shelving is level, secure, all screws in place, no scratches

POWDER

  • All Cabinet trim in place

  • All Door hardware operates/locks smoothly

  • All hinge pins and screws are in place

  • All light bulbs working

  • All pipes for pedestal have escutcheons installed

  • Base board is free of bowing

  • Cabinet doors and hardware are level and secure

  • Cabinets are free of defects

  • Check all electrical outlets for functionality

  • Check all light switches for functionality

  • Check all light switches for functionality. Light first. Fan second

  • Check plan for tempered window locations

  • Compare number of supply vents in room to manual J

  • Confirm exhaust fan works. Turn fan on, locate vent on exterior.

  • Countertops are free of defects

  • Countertops sealed to wall and to cabinets

  • Doors do not rub frame or floor, reveal is consistent

  • Fill sink with water, release drain, check for leaks

  • Flooring is free of defects. No squeaks

  • GFCI outlets are in place and function properly, test all.

  • Hinge/base bump installed on all doors

  • Hot/Cold water are not reversed on sinks

  • HVAC registers are square, not over tightened, free of insulation

  • Light, mirror, and sink centered on each other

  • Mirrors installed, level, secure

  • Pedestal base is secure

  • Review all selections and options for completion and accuracy

  • Sink drain functions properly and drains well when open

  • Sink overflows work sufficiently

  • Switch plates are secure, level, screws aligned

  • Toilet flushes and refills properly without sticking open

  • Toilet is sealed to floor with gap at rear

  • Toilet seat secure with no scratches

  • Toilet supply has escutcheon installed and is flush to wall

  • Toilets are secure and level

  • Tops of door casings are caulked and painted

  • Window/door trim level, flush, good paint coverage, caulked well

  • Windows are clean, operable, no scratches

Checklist

LIVING ROOM

  • # of Low volt feeds in panel are accounted for on exterior/interior of home (no covered outlets)

  • All Door hardware operates/locks smoothly

  • All hinge pins and screws are in place

  • All light bulbs working

  • Base board is free of bowing

  • Ceiling Fan is balanced well. Check pull chains for proper operation

  • Check all electrical outlets for functionality

  • Check all light switches for functionality

  • Check all light switches for functionality. Light first. Fan second

  • Check plan for tempered window locations

  • Compare number of supply vents in room to manual J

  • Doors do not rub frame or floor, reveal is consistent

  • Fireplace operates, space above and below has been cleaned

  • Flooring is free of defects. No squeaks

  • Hinge/base bump installed on all doors

  • HVAC registers are square, not over tightened, free of insulation

  • HVAC returns have clean filters installed

  • Review all selections and options for completion and accuracy

  • Smoke Detector in place. Activated. Dust cover removed. Test for operation

  • Switch plates are secure, level, screws aligned

  • Thermostats installed, level, no paint overspray

  • Tops of door casings are caulked and painted

  • Window/door trim level, flush, good paint coverage, caulked well

  • Windows are clean, operable, no scratches

KITCHEN

  • All appliance clocks are set and synced

  • All Door hardware operates/locks smoothly

  • All hinge pins and screws are in place

  • All light bulbs working

  • All paperwork is organized in a folder in one drawer. Only keep owner’s manuals not

  • installation guides. Remove all plastic

  • Anti Tip Device installed on slide in ranges

  • Base board is free of bowing

  • Cabinet doors and hardware are level and secure

  • Cabinets are free of defects

  • Chandeliers are strait and approximately 60" AFF

  • Check all electrical outlets for functionality

  • Check all light switches for functionality

  • Check all light switches for functionality. Light first. Fan second

  • Check plan for tempered window locations

  • Compare number of supply vents in room to manual J

  • Cooktop is installed, sealed to countertop and secured to cabinets, check operation

  • Countertop has grout caulk between top and tile backsplash

  • Dishwasher drain has back flow loop in place

  • Dishwasher is secure, check operation

  • Doors do not rub frame or floor, reveal is consistent

  • Flooring is free of defects. No squeaks

  • Garbage disposal is free of debris, check operation

  • GFCI outlets are in place and function properly, test all.

  • Hinge/base bump installed on all doors

  • HVAC registers are square, not over tightened, free of insulation

  • Over or oven/micros installed, flush to cabinets/countertops, check operation

  • Review all selections and options for completion and accuracy

  • Sink is sealed to countertop

  • Sink stopper is on site and in drawer

  • Smoke Detector in place. Activated. Dust cover removed. Test for operation

  • Soap dispenser installed has a tube in place

  • Switch plates are secure, level, screws aligned

  • Tops of door casings are caulked and painted

  • Window/door trim level, flush, good paint coverage, caulked well

  • Windows are clean, operable, no scratches

  • Wire shelving is level, secure, all screws in place, no scratches

DINING/BREAKFAST

  • All Door hardware operates/locks smoothly

  • All hinge pins and screws are in place

  • All light bulbs working

  • Base board is free of bowing

  • Check all electrical outlets for functionality

  • Check all light switches for functionality

  • Check all light switches for functionality. Light first. Fan second

  • Check plan for tempered window locations

  • Compare number of supply vents in room to manual J

  • Doors do not rub frame or floor, reveal is consistent

  • Flooring is free of defects. No squeaks

  • Hinge/base bump installed on all doors

  • HVAC registers are square, not over tightened, free of insulation

  • Review all selections and options for completion and accuracy

  • Smoke Detector in place. Activated. Dust cover removed. Test for operation

  • Switch plates are secure, level, screws aligned

  • Tops of door casings are caulked and painted

  • Window/door trim level, flush, good paint coverage, caulked well

  • Windows are clean, operable, no scratches

MUDROOM

  • All Door hardware operates/locks smoothly

  • All hinge pins and screws are in place

  • All light bulbs working

  • Base board is free of bowing

  • Check all electrical outlets for functionality

  • Check all light switches for functionality

  • Check all light switches for functionality. Light first. Fan second

  • Check plan for tempered window locations

  • Compare number of supply vents in room to manual J

  • Doors do not rub frame or floor, reveal is consistent

  • Flooring is free of defects. No squeaks

  • Hinge/base bump installed on all doors

  • HVAC registers are square, not over tightened, free of insulation

  • Review all selections and options for completion and accuracy

  • Switch plates are secure, level, screws aligned

  • Tops of door casings are caulked and painted

  • Window/door trim level, flush, good paint coverage, caulked well

  • Windows are clean, operable, no scratches

  • Wire shelving is level, secure, all screws in place, no scratches

LAUNDRY ROOM

  • All Cabinet trim in place

  • All Door hardware operates/locks smoothly

  • All hinge pins and screws are in place

  • All light bulbs working

  • Base board is free of bowing

  • Cabinet doors and hardware are level and secure

  • Cabinets are free of defects

  • Check all electrical outlets for functionality

  • Check all light switches for functionality

  • Check all light switches for functionality. Light first. Fan second

  • Check plan for tempered window locations

  • Compare number of supply vents in room to manual J

  • Countertops are free of defects

  • Countertops sealed to wall and to cabinets

  • Doors do not rub frame or floor, reveal is consistent

  • Drain Cap on washer box is removed

  • Dryer duct exterior termination verified

  • Dryer vent length of duct sticker is in place

  • Dyer vent trim ring is in place and no paint overspray in/on box

  • Flooring is free of defects. No squeaks

  • GFCI outlets are in place and function properly, test all.

  • Hinge/base bump installed on all doors

  • Hot/Cold water are not reversed on sinks

  • HVAC registers are square, not over tightened, free of insulation

  • Laundry drain box trim ring is in place and no paint overspray in/on box

  • Review all selections and options for completion and accuracy

  • Switch plates are secure, level, screws aligned

  • Tops of door casings are caulked and painted

  • Washer drain pan is positioned correctly, connection is secure, pan not cracked

  • Window/door trim level, flush, good paint coverage, caulked well

  • Windows are clean, operable, no scratches

  • Wire shelving is level, secure, all screws in place, no scratches

MASTER BEDROOM

  • All light bulbs working

  • Base board is free of bowing

  • Ceiling Fan is balanced well. Check pull chains for proper operation

  • Check all electrical outlets for functionality

  • Check all light switches for functionality

  • Check all light switches for functionality. Light first. Fan second

  • Check plan for tempered window locations

  • Compare number of supply vents in room to manual J

  • Doors do not rub frame or floor, reveal is consistent

  • Flooring is free of defects. No squeaks

  • Hinge/base bump installed on all doors

  • HVAC registers are square, not over tightened, free of insulation

  • HVAC returns have clean filters installed

  • Review all selections and options for completion and accuracy

  • Smoke Detector in place. Activated. Dust cover removed. Test for operation

  • Switch plates are secure, level, screws aligned

  • Tops of door casings are caulked and painted

  • Window/door trim level, flush, good paint coverage, caulked well

  • Windows are clean, operable, no scratches

  • Wire shelving is level, secure, all screws in place, no scratches

Checklist

MASTER BATHROOM

  • All light bulbs working

  • Base board is free of bowing

  • Cabinet doors and hardware are level and secure

  • Cabinets are free of defects

  • Check all electrical outlets for functionality

  • Check all light switches for functionality

  • Check all light switches for functionality. Light first. Fan second

  • Check plan for tempered window locations

  • Compare number of supply vents in room to manual J

  • Confirm exhaust fan works. Turn fan on, locate vent on exterior.

  • Countertops are free of defects

  • Countertops sealed to wall and to cabinets

  • Doors do not rub frame or floor, reveal is consistent

  • Fill sink with water, release drain, check for leaks

  • Flooring is free of defects. No squeaks

  • GFCI outlets are in place and function properly, test all.

  • Hinge/base bump installed on all doors

  • Hot/Cold water are not reversed on sinks

  • Hot/Cold water on shower not reversed

  • HVAC registers are square, not over tightened, free of insulation

  • Light, mirror, and sink centered on each other

  • Mirrors installed, level, secure

  • Review all selections and options for completion and accuracy

  • Shower door installed, functional, and free of defects

  • Shower door is sealed to wall and curb and has silicone for first 3" beyond door

  • Shower finishes free of defects

  • Shower valve is flush to wall and sealed around edge

  • Sink drain functions properly and drains well when open

  • Sink overflows work sufficiently

  • Switch plates are secure, level, screws aligned

  • Test tub drains and overflow.

  • Thermostats installed, level, no paint overspray

  • Toilet flushes and refills properly without sticking open

  • Toilet is sealed to floor with gap at rear

  • Toilet seat secure with no scratches

  • Toilet supply has escutcheon installed and is flush to wall

  • Toilets are secure and level

  • Tops of door casings are caulked and painted

  • Tubs free of rust, dents, scratches

  • Window/door trim level, flush, good paint coverage, caulked well

  • Windows are clean, operable, no scratches

  • Wire shelving is level, secure, all screws in place, no scratches

BEDROOM #2

  • Check all light switches for functionality

  • Check all light switches for functionality. Light first. Fan second

  • Check plan for tempered window locations

  • Compare number of supply vents in room to manual J

  • Doors do not rub frame or floor, reveal is consistent

  • Flooring is free of defects. No squeaks

  • Hinge/base bump installed on all doors

  • HVAC registers are square, not over tightened, free of insulation

  • Jumper ducts are in place and both ends are accounted for (not covered up)

  • Review all selections and options for completion and accuracy

  • Smoke Detector in place. Activated. Dust cover removed. Test for operation

  • Switch plates are secure, level, screws aligned

  • Tops of door casings are caulked and painted

  • Window/door trim level, flush, good paint coverage, caulked well

  • Windows are clean, operable, no scratches

  • Wire shelving is level, secure, all screws in place, no scratches

BATHROOM #2

  • Check all light switches for functionality

  • Check all light switches for functionality. Light first. Fan second

  • Check plan for tempered window locations

  • Compare number of supply vents in room to manual J

  • Confirm exhaust fan works. Turn fan on, locate vent on exterior.

  • Countertops are free of defects

  • Countertops sealed to wall and to cabinets

  • Doors do not rub frame or floor, reveal is consistent

  • Fill sink with water, release drain, check for leaks

  • Flooring is free of defects. No squeaks

  • GFCI outlets are in place and function properly, test all.

  • Hinge/base bump installed on all doors

  • Hot/Cold water are not reversed on sinks

  • Hot/Cold water on shower not reversed

  • HVAC registers are square, not over tightened, free of insulation

  • Light, mirror, and sink centered on each other

  • Mirrors installed, level, secure

  • Review all selections and options for completion and accuracy

  • Shower finishes free of defects

  • Shower valve is flush to wall and sealed around edge

  • Sink drain functions properly and drains well when open

  • Sink overflows work sufficiently

  • Switch plates are secure, level, screws aligned

  • Test tub drains and overflow.

  • Toilet flushes and refills properly without sticking open

  • Toilet is sealed to floor with gap at rear

  • Toilet seat secure with no scratches

  • Toilet supply has escutcheon installed and is flush to wall

  • Toilets are secure and level

  • Tops of door casings are caulked and painted

  • Tubs free of rust, dents, scratches

  • Window/door trim level, flush, good paint coverage, caulked well

  • Windows are clean, operable, no scratches

  • Wire shelving is level, secure, all screws in place, no scratches

BEDROOM #3

  • Check all light switches for functionality

  • Check all light switches for functionality. Light first. Fan second

  • Check plan for tempered window locations

  • Compare number of supply vents in room to manual J

  • Doors do not rub frame or floor, reveal is consistent

  • Flooring is free of defects. No squeaks

  • Hinge/base bump installed on all doors

  • HVAC registers are square, not over tightened, free of insulation

  • Jumper ducts are in place and both ends are accounted for (not covered up)

  • Review all selections and options for completion and accuracy

  • Smoke Detector in place. Activated. Dust cover removed. Test for operation

  • Switch plates are secure, level, screws aligned

  • Tops of door casings are caulked and painted

  • Window/door trim level, flush, good paint coverage, caulked well

  • Windows are clean, operable, no scratches

  • Wire shelving is level, secure, all screws in place, no scratches

BATHROOM #3

  • Check all light switches for functionality

  • Check all light switches for functionality. Light first. Fan second

  • Check plan for tempered window locations

  • Compare number of supply vents in room to manual J

  • Confirm exhaust fan works. Turn fan on, locate vent on exterior.

  • Countertops are free of defects

  • Countertops sealed to wall and to cabinets

  • Doors do not rub frame or floor, reveal is consistent

  • Fill sink with water, release drain, check for leaks

  • Flooring is free of defects. No squeaks

  • GFCI outlets are in place and function properly, test all.

  • Hinge/base bump installed on all doors

  • Hot/Cold water are not reversed on sinks

  • Hot/Cold water on shower not reversed

  • HVAC registers are square, not over tightened, free of insulation

  • Light, mirror, and sink centered on each other

  • Mirrors installed, level, secure

  • Review all selections and options for completion and accuracy

  • Shower finishes free of defects

  • Shower valve is flush to wall and sealed around edge

  • Sink drain functions properly and drains well when open

  • Sink overflows work sufficiently

  • Switch plates are secure, level, screws aligned

  • Test tub drains and overflow.

  • Toilet flushes and refills properly without sticking open

  • Toilet is sealed to floor with gap at rear

  • Toilet seat secure with no scratches

  • Toilet supply has escutcheon installed and is flush to wall

  • Toilets are secure and level

  • Tops of door casings are caulked and painted

  • Tubs free of rust, dents, scratches

  • Window/door trim level, flush, good paint coverage, caulked well

  • Windows are clean, operable, no scratches

  • Wire shelving is level, secure, all screws in place, no scratches

Checklist

BEDROOM #4

  • Check all light switches for functionality

  • Check all light switches for functionality. Light first. Fan second

  • Check plan for tempered window locations

  • Compare number of supply vents in room to manual J

  • Doors do not rub frame or floor, reveal is consistent

  • Flooring is free of defects. No squeaks

  • Hinge/base bump installed on all doors

  • HVAC registers are square, not over tightened, free of insulation

  • Jumper ducts are in place and both ends are accounted for (not covered up)

  • Review all selections and options for completion and accuracy

  • Smoke Detector in place. Activated. Dust cover removed. Test for operation

  • Switch plates are secure, level, screws aligned

  • Tops of door casings are caulked and painted

  • Window/door trim level, flush, good paint coverage, caulked well

  • Windows are clean, operable, no scratches

  • Wire shelving is level, secure, all screws in place, no scratches

BATHROOM #4

  • Check all light switches for functionality

  • Check all light switches for functionality. Light first. Fan second

  • Check plan for tempered window locations

  • Compare number of supply vents in room to manual J

  • Confirm exhaust fan works. Turn fan on, locate vent on exterior.

  • Countertops are free of defects

  • Countertops sealed to wall and to cabinets

  • Doors do not rub frame or floor, reveal is consistent

  • Fill sink with water, release drain, check for leaks

  • Flooring is free of defects. No squeaks

  • GFCI outlets are in place and function properly, test all.

  • Hinge/base bump installed on all doors

  • Hot/Cold water are not reversed on sinks

  • Hot/Cold water on shower not reversed

  • HVAC registers are square, not over tightened, free of insulation

  • Light, mirror, and sink centered on each other

  • Mirrors installed, level, secure

  • Review all selections and options for completion and accuracy

  • Shower finishes free of defects

  • Shower valve is flush to wall and sealed around edge

  • Sink drain functions properly and drains well when open

  • Sink overflows work sufficiently

  • Switch plates are secure, level, screws aligned

  • Test tub drains and overflow.

  • Toilet flushes and refills properly without sticking open

  • Toilet is sealed to floor with gap at rear

  • Toilet seat secure with no scratches

  • Toilet supply has escutcheon installed and is flush to wall

  • Toilets are secure and level

  • Tops of door casings are caulked and painted

  • Tubs free of rust, dents, scratches

  • Window/door trim level, flush, good paint coverage, caulked well

  • Windows are clean, operable, no scratches

  • Wire shelving is level, secure, all screws in place, no scratches

BEDROOM #5

  • Check all light switches for functionality

  • Check all light switches for functionality. Light first. Fan second

  • Check plan for tempered window locations

  • Compare number of supply vents in room to manual J

  • Doors do not rub frame or floor, reveal is consistent

  • Flooring is free of defects. No squeaks

  • Hinge/base bump installed on all doors

  • HVAC registers are square, not over tightened, free of insulation

  • Jumper ducts are in place and both ends are accounted for (not covered up)

  • Review all selections and options for completion and accuracy

  • Smoke Detector in place. Activated. Dust cover removed. Test for operation

  • Switch plates are secure, level, screws aligned

  • Tops of door casings are caulked and painted

  • Window/door trim level, flush, good paint coverage, caulked well

  • Windows are clean, operable, no scratches

  • Wire shelving is level, secure, all screws in place, no scratches

BATHROOM #5

  • Check all light switches for functionality

  • Check all light switches for functionality. Light first. Fan second

  • Check plan for tempered window locations

  • Compare number of supply vents in room to manual J

  • Confirm exhaust fan works. Turn fan on, locate vent on exterior.

  • Countertops are free of defects

  • Countertops sealed to wall and to cabinets

  • Doors do not rub frame or floor, reveal is consistent

  • Fill sink with water, release drain, check for leaks

  • Flooring is free of defects. No squeaks

  • GFCI outlets are in place and function properly, test all.

  • Hinge/base bump installed on all doors

  • Hot/Cold water are not reversed on sinks

  • Hot/Cold water on shower not reversed

  • HVAC registers are square, not over tightened, free of insulation

  • Light, mirror, and sink centered on each other

  • Mirrors installed, level, secure

  • Review all selections and options for completion and accuracy

  • Shower finishes free of defects

  • Shower valve is flush to wall and sealed around edge

  • Sink drain functions properly and drains well when open

  • Sink overflows work sufficiently

  • Switch plates are secure, level, screws aligned

  • Test tub drains and overflow.

  • Toilet flushes and refills properly without sticking open

  • Toilet is sealed to floor with gap at rear

  • Toilet seat secure with no scratches

  • Toilet supply has escutcheon installed and is flush to wall

  • Toilets are secure and level

  • Tops of door casings are caulked and painted

  • Tubs free of rust, dents, scratches

  • Window/door trim level, flush, good paint coverage, caulked well

  • Windows are clean, operable, no scratches

  • Wire shelving is level, secure, all screws in place, no scratches

ATTIC

  • A/C unit is strapped to platform

  • All hinge pins and screws are in place

  • All mastic/tape is in good condition

  • Attic access is cleaned off

  • Ceiling accesses are energy rated with weather stripping installed

  • Check all light switches for functionality. Light first. Fan second

  • Doors do not rub frame or floor, reveal is consistent

  • For gas furnaces, caps are removed from condensation line

  • HVAC registers are square, not over tightened, free of insulation

  • Insulation does not block soffit ventilation

  • Insulation Ruler is in place and depth of blow insulation meets code

  • Keyless light installed and switch located near access

  • Line set for HVAC is insulated with no rips

  • No unprotected wiring

  • Overflow pan under A/C unit is clear of debris and drain line is not clogged

  • Review all selections and options for completion and accuracy

  • Sufficient gap at ridge vents

  • Switch plates are secure, level, screws aligned

  • Temporary bracing has been removed from trusses

  • Tops of door casings are caulked and painted

  • Wall accesses have weather stripping installed

  • Window/door trim level, flush, good paint coverage, caulked well

SIGN-OFF

  • Checked by

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.