Information
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Disclaimer
The assessor believes that the fire doorsets identified on the attached schedule have been visually inspected and labelled as required by the appropriate regulatory authorities in accordance with Regulatory Reform (Fire safety Order) 2005. The assessors do not accept responsibility for any consequences arising from the use of the information herein. The report is based on matters which were observed or discussed or came to the attention of the assessors during the day of the inspection and should not be relied upon as an exhaustive record of all possible risks or hazards that may exist or potential improvements that can be made to the fire doors and their sets. Information on the latest legislation can be found on www.hse.gov.uk
Confidentiality Statement
In order to maintain the integrity and credibility of the inspection processes and to protect the parties involved, it is understood that the assessors will not divulge to unauthorised persons any information obtained during this fire door inspection unless legally obligated to do so.
- Fire Door
-
Door Number
Door Location
-
Location
-
Door certification mark
Door
-
Does the door leaf sit against the door jamb and is it free from distortion?
-
Is there suitable signage on the door?
Door Frame
-
Is the door frame in good condition?
-
Is the door stop firmly attached
-
Is the frame-to-door leaf gap consistently 4mm or less
Door Seals
-
Are intumescent strips in place?
-
Are cold smoke seals free from damage?
Door Hinges
-
Is there a minimum of 3 hinges and all the screws fitted?
-
Are all the screws the correct size?
Door Closers
-
Is the closer securely attached to the door and the frame?
-
Is the door closer suitable for the type and weight of door?
-
Open the door to 75mm or 5 degrees. Does it close?
-
If unlatched does the closer hold the door in line with the frame and intumescent seal?
Ironmongery
-
Does the latch hold the door firmly in the frame without significant movement?
Glazing & Glass
-
Is the glass fire rated?
-
Are the glazing beads attached to the door and free from damage?
-
Is the glass free from cracking or damage?
Threshold Gap
-
Is there a consistent gap under the door that allows it to swing without touching the floor covering and less than 8mm
-
If the door leaf is fitted with a threshold seal, does the seal make contact with the floor covering when the door is closed?
Actions
-
Are there any required actions