Title Page
-
Site conducted
-
Document Number
-
Conducted on
-
Prepared by
-
Location
-
Picture of Building
Fire Door Inspection
-
Jackson - Fire & Security: Fire Door Inspection
Door (Full Inspection)
-
Door ID:
-
Picture of Door (Outside)
-
Picture of Door (Inside)
-
Door Access?
-
Door Rating:
- FD20
- FD30
- FD60
- FD120
- FD20S
- FD30S
- FD60S
- FD120S
- Nominal FD30
- Nominal FD60
- Nominal FD120
- Exit Door
- Standard Door
-
Location:
-
Door Dimensions (in mm's)
-
Door Material:
-
Frame Material:
-
Wall Structure Type:
-
Door Set:
-
Frame Passed?
-
Reason for failure:
- Replace Frame Complete to Current Regulations
- Frame is Damaged and Requires Professional Repair
- Fire Stopping Sealant Required around the Door Frame
- Gap in the Frame where old hinges were once fitted. Requires Repair
- Other
-
Additional Comments:
-
Additional Comments:
-
Additional Comments:
-
Ironmongery Present?
-
Type:
-
Ironmongery Passed?
-
Reason for failure:
- Replace Ironmongery to Current Regulations
- The suitability of its conformity to Current Regulations cannot be determined as no kitemark is present nor supporting documentation.
- Door Loose when Latched
- Repairs Required
- Screws Missing
- Unable to verify that Ironmongery complies to current regulations (Advisory Only)
- Other
-
Additional Comments:
-
Additional Comments:
-
Additional Comments:
-
Locks Passed?
- Yes
- No
- Advisory Only
- N/A
-
Reason for failure:
- Repair Panic/Push Bar System
- Replace Panic/Push Bar System
- Repair Lockset
- Replace Lockset
- Replace the inside of the door with a thumb turn style lock for easy exit.
- Unable to verify that Lockset complies to current regulations (Advisory Only)
- Other
-
Additional Comments:
-
Additional Comments:
-
Additional Comments:
-
Vision Panels Present?
-
Size (in mm's)
-
Glass Type:
-
Glass Passed?
-
Reason for failure:
- No Fire Rated Identification on Glass
- Replace Glazing Beads
- Required Glazing Intumescent Seal
- Replace Glazing to Comply with Current Regulations
- The Glass Panel has been removed or is missing. Replace Fire Rated Glass & Associated Fire Stopping Materials
- Unable to verify that Glass complies to current regulations (Advisory Only)
- Other
-
Additional Comments:
-
Additional Comments:
-
Additional Comments:
-
Hinges Passed?
-
Reason for failure:
- Replace Hinges With New 100mm Ballrace Type to Current Regulations
- Requires Missing Screws to Hinge
- Replace Hinge Packing with Intumescent Type
- Maintain Hinges (Clean and Lubricate)
- Requires Additional Bullrace Hinge Fitting to Current Regulations
- Hinges Visibly Weaping and Require Replacements
- Floor / Frame Spring Hinges require replacing
- Unable to verify that Hinges complies to current regulations (Advisory Only)
- Hinges do not comply with current regulations. Replace hinges.
- Other
-
Additional Comments:
-
Additional Comments:
-
Additional Comments:
-
Seals Passed?
-
Reason for failure:
- Fire Stopping Required Around Door Frame
- Replace Existing Intumescent Seals to Current Regulations
- Replace Existing Intumescent Seals & Smoke Seals to Current Regulations
- Router Out Door Edge to Allow for New Intumescent Cold/Smoke Seal to Current Regulations
- Areas of the Door/Frame have Missing Intumescent Seals
- Areas of the Door/Frame have Missing Intumescent & Smoke Seals
- Other
-
Additional Comments:
-
Additional Comments:
-
Additional Comments:
-
Door Closer Present?
-
Door Closer Type:
- Perko Concealed Chain Door Closer
- Overhead Door Closer
- Electric Door Closer
- Side Arm Door Closer
- Floor Spring Door Closer
- Transom Door Closer
- Other
-
Model (If Known)
-
Door Closer Passed?
- Yes
- No
- Advisory Only
- N/A
-
PLEASE NOTE: Concealed Door Closers cannot be adjusted, if adjustment is required please suggest replacement with overhead door closer.
-
Reason for failure:
- Replace Door Closer with Fire Rated Type to Current Regulations
- Door Closer Missing. Install Door Closer with Fire Rated Type to Current Regulations.
- Repair Door Closer and Adjust Accordingly - Door Closes Too Slowly
- Repair Door Closer and Adjust Accordingly -Door Closes Too Fast
- Door Slams
- Door Closer Not Holding Door to it's Frame
- Electrical Door Closer Requires Replacing due to failure.
- Door Fails to Fully Close into it's Frame.
- Unable to Test Closer. Floor type prevents the door closer from completely closing the door.
- Unable to verify that Door Closer complies to current regulations (Advisory Only)
- Other
-
Additional Comments:
-
Additional Comments:
-
Additional Comments:
-
Is a Door Closer Required?
- No
- Install a Fire Door Closer to Current Regulations
-
Structure Passed?
- Yes
- No
- Advisory Only
- N/A
-
Reason for failure:
- Remove Door, and reposition frame to square up with door & Install Compliant Fire Stopping Materials
- Replace Door Complete to Current Regulations
- Replace Frame Complete to Current Regulations
- Replace Door & Frame Complete to Current Regulations
- Ease & Adjust Door
- Repair required on Door where the old lock was fitted.
- Repair required due to Frame where the old lock was fitted.
- Drill holes present on the Door
- Drill holes present on the Frame.
- Door laminate is in poor condition.
- Door is Damaged and Required Professional Repair.
- Door does not fit flush into the frame.
- Door is warped and requires replacement.
- Damage to frame due to Hinges
- Door Doesn't close into frame.
- Other
-
Additional Comments:
-
Additional Comments:
-
Additional Comments:
-
Signage Passed?
- Yes
- No
- Advisory Only
- N/A
-
Reason for failure:
- Requires "Fire Door. Keep Shut" Signage
- Requires "Fire Door. Keep Locked" Signage
- Requires "Fire Door. Keep Clear" Signage
- Requires "Fire Exit. Keep Clear" Signage
- Requires "Push bar to Exit" Signage
- Requires "Automatic Fire Door. Keep Clear" Signage
- Requires "Turn to Open" Signage
- Required "Push to Open" Signage
- Requires Overhead "Fire Exit" Signage
- Requires "This Door Is Alarmed. Fire Exit Only" Signage
- Requires Signage (Other)
- Other
-
Signage Type Required:
-
Additional Comments:
-
Additional Comments:
-
Additional Comments:
-
Gaps Passed?
-
Reason for failure:
- The gap under the door exceeds 10mm.
- The gap under the door exceeds 4mm.
- The gap hinge side exceeds 4mm.
- The gap lock side exceeds 4mm.
- The gap on the top of the door exceeds 4mm.
- Minimal gaps are preventing the door from closing unassisted.
- Gaps exceed tolerance throughout the area of the door. See the image for areas of failure.
- Fit automatic drop down seal to bottom of door - Rebated
- Fit automatic drop down seal to bottom of door - Surface
- Door required lipping added as gaps are too excessive.
- Ease & Adjust Door for Correct Gaps (2-4mm)
- Gap under door under 2mm
- Gap hinge side under 2mm
- Gap lockside under 2mm
- Gap top of the door under 2mm
- Other
-
Additional Information & Comments:
-
Additional Comments:
-
Additional Comments:
-
Door Passed?
-
Inspector Comments:
-
Inspector Comments:
-
Inspector Comments:
Door (Quarterly Inspection)
-
Door ID:
-
Is a Fire Door?
-
Is a Nominal Fire Door?
-
Appropriate Signage?
-
Comment:
-
Comment:
-
Door Damaged or Defective? (Visually)
-
Comment:
-
Comment:
-
Frame Damaged and Defective? (Visually)
-
Comment:
-
Comment:
-
Self Closer Functional & Present?
-
Comment:
-
Comment:
-
All gaps visually within tolerance?
-
Comment:
-
Comment:
-
Are intumescent strips and smoke strips damaged?
- Yes
- No
- Advisory
-
Comment:
-
Comment:
-
Hold-Open Device Functional?
- Yes
- No
- N/A
-
Comments:
-
Double Door Close Correctly in Sequence?
- Yes
- No
- N/A
-
Comment: