Title Page

  • Frequency

  • Conducted on

  • Site conducted

  • Task Number

Pre-Start

  • Weather Conditions

  • Additional comments that may affect accurate inspection and testing

  • Initial Media Capture (Cabinet/Site)

Visual Inspection of:

  • Site

  • Aerial

  • Wiring

  • Land - Vegetation clearing

  • Land - Clear access to sensors

  • Camera alignment

  • Cabinet Security

  • Initial Cabinet Condition Photo

Cleaning of:

  • Rain Gauge

  • Camera Lens

  • Solar Panel

Initial Value

  • Battery value (V)

  • Rain value (m)

  • RSSI value (dBm)

  • River value (m)

  • River Actual Level (m)

  • Offset (m)

Power and Solar

  • Battery Installation Date

  • Battery Type (Volts, VA)

  • Condition rating of 1 = very good, 5 = very bad

  • Battery Condition

  • Battery Connection (Clean/Tight)

  • Load Current (AMPs)

  • Solar Panel Connection (Clean/Tight)

  • Battery Voltage Under Load (Volts)

  • Aerial

  • System Operational

  • PV Output Voltage

  • Charge Current

  • Confirm Base Station Power Supply, Comms and Connectivity

Telemetry

  • Comms Type (4G/Cellular, UHF)

  • Antenna (Frequency/type)

  • Cannister Model

  • Canister SN

  • System RSSI (dBm)

  • Modem Type (eg Intercel Model Number)

  • Power (W)

  • Comms with STREAMS System

  • Communications and Radio Signal Strength

  • Redundant Comms and Repeater Functionality

  • Run Simulations to Confirm Triggering of Signage and Messaging

Rain Gauge

  • Applicable to site?

Rain Gauge Checks

  • Gauge Level

  • Clearance Sufficient (Trees/Structures)

  • Funnel/Drain Clean

Rain Gauge Characteristics

  • Bucket Size (0.5 mm, 1 mm, other)

  • Rim Height

  • Catch Diameter

Rain Gauge Calibration and Adjustment

  • Vol. of FCD

  • Start

  • Finish

  • Result

  • Expected # of Tips

  • Result

  • % Error

  • Pass/Fail (> +/-6%)

  • Test Tip Successful

  • Departure Rain Value

  • Comments

River Level 1

  • Applicable to site?

River Level Checks

  • Orifice Secured

  • Pipework Secured

  • System Purged

  • Leak Test Passed

  • Leak Test Pressure (metres)

Bubble Rate

  • Rate on Arrival (minutes)

  • Rate on Departure (minutes)

Compressor Function

  • Start Pressure (kPa)

  • Cut Off Pressure (kPa)

River Level Calibration

  • Sensor Range (metres)

  • Pressure Calibrator (Make/Model)

SCADA Check

  • Onsite (metres)

  • SCADA (metres)

  • Offset (metres)

  • Other (metres)

Bubbler Calibration

  • Number of values

Value 1

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 1

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 2

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 1

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 2

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 3

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 1

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 2

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 3

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 4

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 1

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 2

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 3

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 4

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 5

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

  • Signal Interval (mins)

  • Increment (mins)

  • Sample Interval (mins)

  • Level System Status

River Level 2

  • Applicable to site?

River Level Checks

  • Orifice Secured

  • Pipework Secured

  • System Purged

  • Leak Test Passed

  • Leak Test Pressure (metres)

Bubble Rate

  • Rate on Arrival (minutes)

  • Rate on Departure (minutes)

Compressor Function

  • Start Pressure (kPa)

  • Cut Off Pressure (kPa)

River Level Calibration

  • Sensor Range (metres)

  • Pressure Calibrator (Make/Model)

SCADA Check

  • Onsite (metres)

  • SCADA (metres)

  • Offset (metres)

  • Other (metres)

Bubbler Calibration

  • Number of values

Value 1

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 1

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 2

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 1

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 2

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 3

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 1

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 2

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 3

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 4

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 1

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 2

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 3

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 4

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

Value 5

  • DPI Pump Value (metres)

  • Level Sensor Value (metres)

  • Error (metres)

  • Pass (Error < +/-0.01m)

  • Signal Interval (mins)

  • Increment (mins)

  • Sample Interval (mins)

  • Level System Status

SCADA Confirmation

  • Applicable to Site?

  • SCADA Confirmed

Departure Values

  • Battery Value (V)

  • River Value (m)

  • Rain Value (m)

  • RSSI Value (dBm)

Flashing Lights Operation and Testing 1

  • Applicable to site?

  • Were the flashing lights tested and operational when river levels were simulated?

  • Did the flashing lights turn off at the expected time?

  • Were the lights tested in manual from SCADA?

  • Location of flashing lights?

Flashing Lights Power and Solar

  • Applicable to site?

  • Battery Installation Date

  • Type

  • Battery Condition

  • Battery Connection

  • Load Current (AMPs)

Battery Volts

  • Under Load (Volts)

  • Solar Panel Clean

  • Solar Panel Connection

  • Aerial

  • System Operational

  • PV Output Voltage

  • Charge Current

  • Confirm Base Station Power Supply, Comms and Connectivity

Flashing Lights Telemetry

  • Applicable to site?

  • Comms type

  • Antenna

  • Cannister Model

  • Fz

  • System RSSI (dBm)

  • Modem Type

  • Canister SN

  • Power

  • Comms with STREAMS system

  • Communications and radio signal strength

  • Redundant comms and repeater functionality

  • Run simulations to confirm triggering of signage and messaging

Flashing Lights Operation and Testing 2

  • Applicable to site?

  • Were the flashing lights tested and operational when river levels were simulated?

  • Did the flashing lights turn off at the expected time?

  • Were the lights tested in manual from SCADA?

  • Location of flashing lights?

Flashing Lights Power and Solar

  • Applicable to site?

  • Battery Installation Date

  • Type

  • Battery Condition

  • Battery Connection

  • Load Current (AMPs)

Battery Volts

  • Under Load (Volts)

  • Solar Panel Clean

  • Solar Panel Connection

  • Aerial

  • System Operational

  • PV Output Voltage

  • Charge Current

  • Confirm Base Station Power Supply, Comms and Connectivity

Flashing Lights Telemetry

  • Applicable to site?

  • Comms type

  • Antenna

  • Cannister Model

  • Fz

  • System RSSI (dBm)

  • Modem Type

  • Canister SN

  • Power

  • Comms with STREAMS system

  • Communications and radio signal strength

  • Redundant comms and repeater functionality

  • Run simulations to confirm triggering of signage and messaging

Faults

  • Were Any Faults Found During Maintenance?

  • Comments on Faults Found

  • Before and After Photos Must be Attached to Work Order

  • Departing Media

Additional Work

  • Final Cabinet Condition Photos

  • Site Overview Photos

  • Any additional work carried out this inspection

  • Future recommendations/work

  • Other photos:

Personnel

  • Leading Tradesman

  • Tradesman

  • Other

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.