Basic Skills Test
CCN1 (Core Elements)
-
Combustion air can be taken from a Bathroom or Shower room.
-
Compartment ventilation is only required where an open flue appliance is installed in a compartment.
-
The definition of a flue is a passage for conveying the products of combustion from an appliance to outside atmosphere.
-
Only balanced flue appliances are permitted in sleeping area's
-
Pipes shall traverse a cavity wall through a continuous sleeve by the shortest practicable route.
-
When uncompleted jobs are left unattended the installation and work area must be left safe.
-
Landlords are required to have appliances installed in their rented accommodation tested for safety on a yearly basis
-
A permanent notice shall be prominently displayed on or near to all emergency controls indicating the actions to be taken in the event of an escape of gas
-
CO2 and H2O are produced as a result of the complete combustion of natural gas and liquid petroleum gasses.
-
Electronic portable flue gas analysers that calculate CO2 levels from an O2 measurement are regarded as being suitable for measuring ambient levels of CO2 in dwellings.
Appliances
-
CKR1
Cooker
-
A freestanding cooker fitted between kitchen units will still require a stability device to be fitted
-
The plugin connection should be sited approximately 600mm from the floor to ensure the flexible tubing will hang in a loop behind the appliance without touching the floor.
-
When an appliance is found with a defective flame supervision device, the device may be by-passed until a replacement part is fitted provided the customer agrees to the action and the appliance is suitably labelled.
-
Where a cooker is installed with a stability bracket there is no requirement regarding proximity of combustible surfaces.
-
A liquid expansion flame supervision device may remain in the open position if the sensing tube is broken causing the liquid to drain out of the control.
-
CENWAT
Heating
-
A fan assisted flue system fitted to a wall hung central heating appliance must incorporate a means of isolating the supply if the fan should fail.
-
A flueless sink water heater may be installed to supply a dishwasher.
-
Back boilers located behind a gas fire are exempt from a landlords responsibility regarding servicing and safety checks.
-
A modureg can be described as a servo which acts upon a regulator, by altering the voltage applied to the modureg solenoid the burner is automatically adjusted.
-
The terminal of a balanced flue boiler should be protected with a guard if there is any risk that persons may come into contact with the terminal.
-
HTR1
Fire
-
A brick chimney with dimensions of 225mm x 225mm will normally be adequate for a domestic gas fire
-
An open flue gas fire must be able to operate correctly whether or not extract or ceiling fans are running, even if the fans are located in a different room to the gas fire.
-
The physical condition of a fuel effect gas fire should be checked before the appliance is connected to the gas supply and flue system.
-
A screw down restrictor elbow is an acceptable means of shutting of the gas supply to a radiant convector gas fire with reference to regulation 26 of the gas safety regulations.
-
If the fan proving switch fitted to a gas fire / heater which has a mechanically powered flue fails to the open position, The main gas valve will remain open.