Information
-
Document No.
-
1. Communities
- Atherstone VIC
- Laurimar VIC
- Harpley VIC
- Craigieburn VIC
- Mayfield VIC
- Aurora VIC
- Sant VIC
- Edgewater VIC
- Blakes Crossing SA
- Springwood SA
-
2. Contractor
-
3. Project Manager / Supervisor
-
4. Date
-
5. Area of inspection
-
Assessor
-
Location
-
Personnel
GMR 1 PREVENTION / GMR 2 PERIMETER PROTECTION
-
1.1 Physical barriers
-
1.2 Harness if required for secondary restraint & competency assessed
-
1.3 SWMS in place with adequate controls
-
1.4 Rescue procedures in place
-
2.1 Physical barriers of sufficient height and strength erected where persons
GMR 3 FORMWORK / GMR 4 FORMWORK
-
3.1 Fabricated at ground level where possible
-
3.2 Fall risks managed
-
3.3 Installed to design
-
4.1 Covers secured (screwed or bolted but not nailed) with warning signage
-
4.2 When covers removed for work purposes secondary measures installed to reduce fall risk
GMR 5 SCAFFOLDS, TEMPORARY WORKS
-
5.1 No mixing of components
-
5.2 Inspection & tagging regime in place
-
5.3 Calculations & drawings
-
5.4 Erected, altered & dismantled by competent persons
-
5.5 Free from defects
-
5.6 Ladders extending 1M above egress
-
5.7 Fall risks managed
-
5.8 Boarded/planked out/<br>
-
5.9 High risk temporary structures eg billboards/hoarding – design & certification paperwork maintained<br>
GMR 6 WORK PLATFORMS
-
6.1 SWMSs in place with adequate controls
-
6.2 Harnesses in use in boom type EWPs
-
6.3 Anchor points must be engineered
-
6.4 Competency records held
-
6.5 Documented inspections completed
GMR 7 LADDERS
-
7.1 Use minimised & safer methods selected where possible
-
7.2 Step ladders only used for 15 mins or less
-
7.3 Industrially rated (stickered) & minimum 120kg rating
-
7.4 In good condition
-
7.5 Secured to prevent movement
-
7.6 Non-conductive ladders for electrical works
-
7.7 Extending at least 1M above egress point
GMR 8 FALL OF MATERIALS / GMR 9 SITE ACCESS CONTROL / GMR 10 FENCING
-
8.1 Tethers, catch nets, exclusion zones in place
-
8.2 Housekeeping to minimise materials which could fall
-
9.1 Unauthorised persons prevented from entering & entry/exit records maintained<br> <br> <br> <br>
-
10.1 In place for all high risk activities & complete (no gaps where public could enter
-
10.2 Erected to manufacturers requirements
-
10.3 Documented inspections taking place
GMR 11 PUBLIC PROTECTION / GMR 12 PEDESTRIAN AND VEHICLE SAFETY
-
11.1 Protection of public from construction activities including works inside fenced perimeters & also traffic movements
-
11.2 Road & access ways clean & free from material & waste
-
11.3 Loads secured prior to exiting site
-
12.1 Separate entrances for pedestrians & vehicles
-
12.2 Parking separation LV/HV with reverse parking
-
12.3 Delivery procedures in place
-
12.4 Vehicles choked/braked before unloading or leaving
-
12.5 TMP’s in place
-
12.6 Licensed drivers/operators
-
12.7 No use of phones & safety devices (seatbelts, beacons etc in use)
GMR 13 TOOLS & EQUIPMENT
-
13.1 Inspection, testing & preventative maintenance regimes in place
-
13.2 In good condition
GMR 14 HOUSEKEEPING
-
14.1 Clean & tidy
-
14.2 Clear access maintained
-
14.3 Materials stored/stacked correctly
-
14.4 Hazardous substances stored in accordance with SDS & segregation requirements
-
14.5 Combustibles away from flammable products
-
14.6 Products labelled & spill kits available
-
14.7 Sharp edges (nails/star pickets etc) managed (eg denailed/capped
-
14.8 Signage (PC, PPE, No Smoking, traffic) in place
-
14.9 Waste bins (including recycling) available & emptied when required
GMR 15 EXCAVATIONS / GMR 16 WORK AROUND WATER
-
15.1 Excavation permit in place
-
15.2 Services located & marked up before works commence
-
15.3 Inspections (documented) by a competent person
-
15.4 Excavations benched, battered or shored
-
15.5 Adjacent structures supported
-
15.6 Materials/traffic routes away from zone of influence
-
15.7 Barriers and signage installed
-
15.8 Safe access via ramps, ladders, stairs
-
15.9 Well ventilated & water ingress controlled
-
15.10 Spoil out of zone of influence & stored safely
-
16.1 Life jackets being worn, rescue equipment available<br> <br> <br> <br>
GMR 17 SAFE USE OF PLANT
-
17.1 Ticketed operators
-
17.2 In good condition & pre-start completed
-
17.3 Risk assessment & SWMSs available
-
17.4 ROPs, seatbelts, flashing beacon, audible devices
-
17.5 Fall risks (hand rails) managed
-
17.6 Exclusion zone in place
-
17.7 Maintained with records available
GMR 18 CRANES AND LIFTING EQUIPMENT
-
18.1 Safety devices (eg load indicators/overload alarms
-
18.2 Lifting gear inspected, in good condition & used for its intended use & contained in a register
-
18.3 Competency records held
-
18.4 Communication protocol established
-
18.5 Safety hooks/tag lines in use
GMR 19 GMR 19 ELECTRICAL SAFETY
-
19.1 RCD’s/ELCB fitted
-
19.2 Cables do not create tripping hazard nor are subject to physical damage
-
19.3 Tested & tagged with register maintained
-
19.4 No live work except under certain conditions
-
19.5 LOTO in place & carried out by competent person
-
19.6 Adequate lighting with emergency back-up (where required
GMR 20 HAZARDOUS SUBSTANCES
-
20.1 SDS available & in register – accessible to workers
-
20.2 Stored, used & disposed in accordance with SDS
-
20.3 PPE as per SDS
GMR 21 PPE / GMR 22 CONFINED SPACES
-
21.1 Hard hat, glasses, gloves, high vis & boots & sun protection (brims, longs, sunscreen)
-
21.2 Additional PPE dependent on task
-
21.3 Signage at site entrances & where additional risks exist
-
21.4 Stock available for workers & visitors
-
22.1 Signed & protected to prevent access
-
22.2 Permit/SWMSs & competent persons
-
22.3 Rescue procedures & equipment
-
22.4 Watch installed 100% of time persons in CS
GMR 23 MANUAL HANDLING/ GMR 24 LONE WORKING / GMR 25 WELFARE
-
23.1 Tasks assessed & safe lifting techniques identified
-
23.2 Lifting aids in place
-
24.1 Avoided where possible & systems in place to manage risk if unavoidable<br> <br> <br> <br>
-
25.1 Toilets, wash facilities, drinking water<br> <br> <br> <br>
GMR 26 FIRE SAFETY & EMERGENCIES
-
26.1 Minimise accumulation of combustibles
-
26.2 Flashback arrestors on oxy acet
-
26.3 Smoking only in designated areas
-
26.4 Hot work under permit
-
26.5 Emergency equipment available, tested/tagged & unobstructed with inspection regime in place
-
26.6 Trained responders (fire, first aid, confined space etc)
-
26.7 Muster points/routes identified
GMR 27 STORMWATER, SEDIMENT & EROSION CONTROL / GMR 28 AIR AND NOISE EMISSIONS
-
27.1 Uncontrolled discharges prevented
-
27.2 Controls installed as designed
-
28.1 Dust suppression<br>
-
28.2 Air and noise impacts assessed and controlled
-
29.1 Contamination sources identified & segregated with controls identified to allow works to proceed<br> <br> <br> <br>
GMR 30 BIODIVERSITY, HERITAGE & ARTEFACTS / GMR 31 WASTE MANAGEMENT
-
30.1 Designated zones identified, signed & segregated with controls identified for works
-
30.2 Work ceased where items discovered to allow for determination
-
31.1 Waste segregated for recycling & stored to prevent unauthorised access/uncontrolled release
-
31.2 Excavated material reused on site where possible
-
31.3 Service of plant & equipment offsite where possible