Information
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
OSHA 300 Log / Right to Know
-
Does the location have the previous year OSHA 300 log posted in a visible location (February 1st thru April 30)?
-
Recommended Corrective Action
-
Does the location have the current Right-to-Know Corporate Safety Policy information posted in a visible location?
-
Recommended Corrective Action
Chemicals
-
Are chemicals stored in the proper approved containers and dispensers?
-
Recommended Corrective Action
-
Flammable Liquid Containers spring loaded, self closing, and contain s flame arrester?
-
Recommended Corrective Action
-
Are flammable liquids stored in closed metal storage units?
-
Recommended Corrective Action
-
Are metal containers for combustible rubbish / rags provided and clearly marked?
-
Recommended Corrective Action
-
Are chemical containers labeled with the proper chemical name and required information?
-
Recommended Corrective Action
-
Dispensing and storage - is there binding, grounding, or ignition source prevention?
-
Recommended Corrective Action
-
Are flammable liquids stored outside flammable cabinets?
-
Recommended Corrective Action
-
Are MSDS's available for all chemicals present on site?
-
Recommended Corrective Action
-
Does the location have a MSDS coordinator?
-
Recommended Corrective Action
-
Are oxygen and acetylene tanks stored according to MIOSHA standards (chains, brackets, or other restraining device / caps replaced when in storage / storage area labeled / storage area protected from tampering and damage / gauges not corroded or broken / etc)?
-
Recommended Corrective Action
Fire Extinguishers & Fire Protection
-
Have fire extinguishers been inspected monthly and annually?
-
Recommended Corrective Action
-
Are fire extinguishers mounted, located, and marked clearly for availability?
-
Recommended Corrective Action
-
Are exit signs clearly marked and illuminated?
-
Recommended Corrective Action
-
Are fire exits unobstructed and accessible?
-
Recommended Corrective Action
-
Are aisles and emergency routes at least 36" in width per MIOSHA Part 6?
-
Recommended Corrective Action
-
Are audio and visual fire alarms in working order and have they been inspected?
-
Recommended Corrective Action
-
Do employees have good working knowledge of the locations emergency evacuation plan?
-
Recommended Corrective Action
Visual Observations - Opportunities
-
Are material storage areas organized?
-
Recommended Corrective Action
-
Do trip hazards exist?
-
Recommended Corrective Action
-
Do slip hazards exist?
-
Recommended Corrective Action
-
Do air tools have dead head pressure <30psi?
-
Recommended Corrective Action
-
Are hand and portable tools in good condition?
-
Recommended Corrective Action
-
Are portable tools either grounded or double insulated?
-
Recommended Corrective Action
-
Is the rated capacity indicated on jacks / jack stands?
-
Recommended Corrective Action
-
Are eyewash stations available according to applicable standards (25ft for ph<2 or >11, 100ft for ph >2, <4 or >9, <12.5)
-
Recommended Corrective Action
-
Is signage posted indicating the types of PPE required in certain areas of the location?
-
Recommended Corrective Action
-
Is visitor PPE available for PPE required areas?
-
Recommended Corrective Action
Pinch Points / Guarding
-
Is equipment guarding provided for all equipment / machinery?
-
Recommended Corrective Action
-
Are there equipment emergency stop buttons?
-
Recommended Corrective Action
-
Guarding by location - is guarding provided 85" measured from work surface up and into hazard?
-
Recommended Corrective Action
-
Abrasive Wheels - tongue guards 1/4" from wheel, work rest 1/8 from wheel, wheel & spindle guarded?
-
Recommended Corrective Action
-
Are guards available within 7' of floor or platform for rotating equipment?
-
Recommended Corrective Action
-
Are vertical band saw adjustable to within 1/4"?
-
Recommended Corrective Action
Fixed & Portable Ladders
-
Are ladders in good condition (no splits through rails, gouges, dents, worn, crushed, cracked, missing steps, broken, bent, etc)?
-
Recommended Corrective Action
-
Are portable ladders stored & secured in a manner to prevent tipping / damage?
-
Recommended Corrective Action
Floor & Wall Openings, Stairways, and Lighting
-
Fixed Stairs - uniform treads and risers, tread >/= 8", rise & run = 17"-18" total, stair rail on any open side, minimum stair width = 22"?
-
Recommended Corrective Action
-
Platforms - if greater than 4ft, a standard barrier present (42" high with mid rail)
-
Recommended Corrective Action
-
Access to elevations - are appropriate means to access another elevation in excess of 16" present (flight of stairs, fixed industrial stair, ramp (12" run, 1" rise), or fixed ladder)?
-
Recommended Corrective Action
-
Are there are 4 or more rises is there a hand rail?
-
Recommended Corrective Action
-
Are there stair or stair railing obstructions?
-
Recommended Corrective Action
-
Does fall protection meet the following: barrier (200# force), tether so an employee cannot get to the edge, fall arrest (5000# rating)
-
Recommended Corrective Action
Grounding
-
Is the welding machine frame grounded?
-
Recommended Corrective Action
-
Do wet locations, enclosed, and confined spaces have GFCI?
-
Recommended Corrective Action
-
Are welding curtains available and used?
-
Recommended Corrective Action
-
Welding Machines: is the cord insulation and conductors in good condition ( no cuts in insulation, no exposed or bare conductors of an arc welding machine)?
-
Recommended Corrective Action
Powered Industrial Trucks
-
Do operators have permits (permit must include employers name, restrictions, types of trucks, date issued, expiration, and issuing authority)?
-
Recommended Corrective Action
-
Are trailer wheels chocked when loading or unloading with powered industrial trucks (no less than 2 wheels)?
-
Recommended Corrective Action
Overhead & Gantry Cranes
-
Is there a record of inspections of overhead cranes for 2 years?
-
Recommended Corrective Action
-
Is the crane lifting capacity indicated on both sides of the cranes?
-
Recommended Corrective Action
-
Is there a positive red stop device for the pendant?
-
Recommended Corrective Action
-
Are crane operators trained?
-
Recommended Corrective Action
Confined Spaces
-
Are confined spaces individually labeled and indicated on an inventory list
-
Recommended Corrective Action
-
Have employees been trained on confined spaces?
-
Recommended Corrective Action
-
Does the location conduct yearly evaluations of the confined space permits?
-
Recommended Corrective Action
Electrical Equipment
-
Are flex cords running through holes in walls/floors/doors?
-
Recommended Corrective Action
-
Are flex cords used in lieu of fixed wiring?
-
Recommended Corrective Action
-
Is there any damaged or exposed live parts?
-
Recommended Corrective Action
-
Are covers off exposing live parts?
-
Recommended Corrective Action
-
Are cords in poor condition?
-
Recommended Corrective Action
-
Are ground plugs missing, modified, or broken?
-
Recommended Corrective Action
-
Is conduit pulled from fitting?
-
Recommended Corrective Action
-
Is access impeded to disconnecting means?
-
Recommended Corrective Action
-
Is disconnect labeling missing or inadequate?
-
Recommended Corrective Action
Air Receivers
-
Do air receivers have an indicator gauge, relief valve, drain valve?
-
Recommended Corrective Action
-
Are relief valves tested frequently?
-
Recommended Corrective Action