Title Page
-
Company Name
-
Prepared by
-
LOC ID
-
SAM ID
-
Address
-
Locational
-
Date Conducted On
Initial Tap Findings
-
Tap Before Photo
-
Tap Reading Photo
-
High Frequency 743 MHz Tap Reading
-
Tap After Photo
-
Was Professional Traffic Control required on site (ZZ-2c)?
-
Sequence Number
-
Have you provided your Traffic Control Quote to your Team Manager?
-
Traffic Control Photos
-
Was a second person required on site for safety reasons (ZZ-1a1)?
-
Sequence Number
-
Type of Installation
Lead-in construction
-
Lead-in construction type
Underground Lead-in Details
-
Your Lead-in Length has exceeded 40m please ensure RG11 is installed.
-
Cable Type
-
What type of Lead-in was required on site?
-
Sequence Number
-
Lead-in Area Before
-
Lead-in Work During
-
Lead-in After
-
Was Lead-in over 40m?
-
Was there more than 20m of Trenching in OTR inside the customers property?
-
Was there more than 2 metres of trenching in OTR required from the property boundary to the Network pit?
-
Was there any Non-Trenching Methods used?
-
Was there any Rock
-
Rock Photos
-
Sequence Number
-
Sequence Number
-
Groundomat Photo
-
Groundomat Distance Photo
-
Establishment Charge (FF-12g2)
-
Sequence Number
-
Boring Photo
-
Boring Distance Photo
-
Establishment Charge (FF-12g1)
-
Was there any Breakout & Reinstatement
-
Breakout Details
- Breakout up to 75mm thickness FF18a per sq m
- Breakout up to 150mm thickness FF18b per sq m
- Breakout over 150mm thickness FF18c per sq m
-
Breakout photos
-
Breakout photos
-
Breakout photos
-
Reinstatement Types
- Reinforced Concrete
- Unreinforced concrete
- Asphalt
- Bricks or Pavers
- Other
- Temporary
-
Reinstatement Details
- Up to 75mm FF19a1 per sq m
- 75mm to 100mm thick FF19a2 per sq m
- 100mm to 150mm thick FF19a3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to25mm thick FF19c1 per sq m
- 25mm to 50 mm thick FF19c2 per sq m
- 50mm to 75mm thick FF19c3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Detail
- Remove 80mm thickness of Bricks or Pavers (FF19d1)
- Lay 80mm thickness of Bricks or Pavers (FF19d2)
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Turf FF19e1
- Kerb and Channel FF19e2
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Cold Mix FF19f1 up to 25mm thick per sq m
- Cold Mix FF19f2 25 to 50mm thick per sq m
- Cold Mix FF19f3 50 to 75 mm thick per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to 100mm FF19b1 per sq m
- 100 to 150mm thick FF19b2 per sq m
- 150 to 200mm thick FF19b3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Did you provide a conduit entry into an Asbestos pit (FF-4c)
-
Asbestos Photos
-
Was a pit required to be installed over existing conduit (FF-2b1)?
-
Sequence Number
-
Was P50 trenching required on site?
-
Sequence Number
-
Was a new pit required to be installed (FF-1b1)?
-
Was There Any Blockages?
-
Type of Blockage
- High Pressure Spit Water EE14f each
- Low Pressure Hose EE14g each
- Network Blockage up to 50mm EE14a1 each
- Locate Buried Pits FF15
-
Buried Pit before
-
Buried Pit After
-
Spit water flush photo
-
Low pressure flush photo
-
Blockage Before
-
Blockage Repaired
-
Blockage Area After
-
Sequence Number
-
Was there any E/O
-
E/O Length EE14c1
-
Additional length photo
-
E/O Depth EE14E1
-
Additional depth photo
-
Was there any Breakout & Reinstatement
-
Breakout Details
- Breakout up to 75mm thickness FF18a per sq m
- Breakout up to 150mm thickness FF18b per sq m
- Breakout over 150mm thickness FF18c per sq m
-
Breakout photos
-
Breakout photos
-
Breakout photos
-
Reinstatement Types
- Reinforced Concrete
- Unreinforced concrete
- Asphalt
- Bricks or Pavers
- Other
- Temporary
-
Reinstatement Details
- Up to 75mm FF19a1 per sq m
- 75mm to 100mm thick FF19a2 per sq m
- 100mm to 150mm thick FF19a3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to25mm thick FF19c1 per sq m
- 25mm to 50 mm thick FF19c2 per sq m
- 50mm to 75mm thick FF19c3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Detail
- Remove 80mm thickness of Bricks or Pavers (FF19d1)
- Lay 80mm thickness of Bricks or Pavers (FF19d2)
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Turf FF19e1
- Kerb and Channel FF19e2
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Cold Mix FF19f1 up to 25mm thick per sq m
- Cold Mix FF19f2 25 to 50mm thick per sq m
- Cold Mix FF19f3 50 to 75 mm thick per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to 100mm FF19b1 per sq m
- 100 to 150mm thick FF19b2 per sq m
- 150 to 200mm thick FF19b3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Was Lead-in over 40m?
-
Was There Any Blockages?
-
Type of Blockage
- High Pressure Spit Water EE14f each
- Low Pressure Hose EE14g each
- Locate and Repair Lead-in Pipe 20mm MM8a1 each
- Y Joiner used MM8a2 per Y joiner
- Network Blockage up to 50mm EE14a1 each
- Locate Buried Pits FF15
-
Buried Pit before
-
Buried Pit After
-
Spit water flush photo
-
Low pressure photo
-
Sequence Number
-
Blockage Before Photo
-
Blockage Repair Photo
-
Blockage Area After Photo
-
Was there any Breakout & Reinstatement
-
Breakout Details
- Breakout up to 75mm thickness FF18a per sq m
- Breakout up to 150mm thickness FF18b per sq m
- Breakout over 150mm thickness FF18c per sq m
-
Breakout photos
-
Breakout photos
-
Breakout photos
-
Reinstatement Types
- Reinforced Concrete
- Unreinforced concrete
- Asphalt
- Bricks or Pavers
- Other
- Temporary
-
Reinstatement Details
- Up to 75mm FF19a1 per sq m
- 75mm to 100mm thick FF19a2 per sq m
- 100mm to 150mm thick FF19a3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to25mm thick FF19c1 per sq m
- 25mm to 50 mm thick FF19c2 per sq m
- 50mm to 75mm thick FF19c3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Detail
- Remove 80mm thickness of Bricks or Pavers (FF19d1)
- Lay 80mm thickness of Bricks or Pavers (FF19d2)
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Turf FF19e1
- Kerb and Channel FF19e2
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Cold Mix FF19f1 up to 25mm thick per sq m
- Cold Mix FF19f2 25 to 50mm thick per sq m
- Cold Mix FF19f3 50 to 75 mm thick per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to 100mm FF19b1 per sq m
- 100 to 150mm thick FF19b2 per sq m
- 150 to 200mm thick FF19b3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Sequence Number
-
Before Photo
-
Y Joiner Installed
-
Area After Photo
-
Was there additional metres above 2m required as part of a LIC extension (MM-6b1)?
-
Was there any Breakout & Reinstatement
-
Breakout Details
- Breakout up to 75mm thickness FF18a per sq m
- Breakout up to 150mm thickness FF18b per sq m
- Breakout over 150mm thickness FF18c per sq m
-
Breakout photos
-
Breakout photos
-
Breakout photos
-
Reinstatement Types
- Reinforced Concrete
- Unreinforced concrete
- Asphalt
- Bricks or Pavers
- Other
- Temporary
-
Reinstatement Details
- Up to 75mm FF19a1 per sq m
- 75mm to 100mm thick FF19a2 per sq m
- 100mm to 150mm thick FF19a3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to25mm thick FF19c1 per sq m
- 25mm to 50 mm thick FF19c2 per sq m
- 50mm to 75mm thick FF19c3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Detail
- Remove 80mm thickness of Bricks or Pavers (FF19d1)
- Lay 80mm thickness of Bricks or Pavers (FF19d2)
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Turf FF19e1
- Kerb and Channel FF19e2
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Cold Mix FF19f1 up to 25mm thick per sq m
- Cold Mix FF19f2 25 to 50mm thick per sq m
- Cold Mix FF19f3 50 to 75 mm thick per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to 100mm FF19b1 per sq m
- 100 to 150mm thick FF19b2 per sq m
- 150 to 200mm thick FF19b3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Sequence Number
-
Blockage Before
-
Blockage Repaired
-
Blockage Area After
-
Was there any E/O
-
E/O Length EE14c1
-
Additional length photo
-
E/O Depth EE14E1
-
Additional depth photo
-
Was there any Breakout & Reinstatement
-
Breakout Details
- Breakout up to 75mm thickness FF18a per sq m
- Breakout up to 150mm thickness FF18b per sq m
- Breakout over 150mm thickness FF18c per sq m
-
Breakout photos
-
Breakout photos
-
Breakout photos
-
Reinstatement Types
- Reinforced Concrete
- Unreinforced concrete
- Asphalt
- Bricks or Pavers
- Other
- Temporary
-
Reinstatement Details
- Up to 75mm FF19a1 per sq m
- 75mm to 100mm thick FF19a2 per sq m
- 100mm to 150mm thick FF19a3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to25mm thick FF19c1 per sq m
- 25mm to 50 mm thick FF19c2 per sq m
- 50mm to 75mm thick FF19c3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Detail
- Remove 80mm thickness of Bricks or Pavers (FF19d1)
- Lay 80mm thickness of Bricks or Pavers (FF19d2)
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Turf FF19e1
- Kerb and Channel FF19e2
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Cold Mix FF19f1 up to 25mm thick per sq m
- Cold Mix FF19f2 25 to 50mm thick per sq m
- Cold Mix FF19f3 50 to 75 mm thick per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to 100mm FF19b1 per sq m
- 100 to 150mm thick FF19b2 per sq m
- 150 to 200mm thick FF19b3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
PCD Testing and Final Photos
-
PCD installed
-
After photo open
-
PCD installed in an accessible area
-
PCD Strength Photo
-
High Frequency 743 MHz PCD Reading
Aerial Lead-In Details
-
Your Lead-in Length has exceeded 40m please ensure RG11 is installed.
-
Cable Type
-
Lead-In Photo
-
Was Additional Span Required
-
Was there E/O installation of new coaxial drop in-span required (HFC-9a2)?
-
In-span coaxial drop Photo
-
Was there E/O for additional spans of aerial drop HFC-9a3?
-
Additional Span Photos
-
New House Riser Installed?
-
Riser Type Installed?
-
Fascia Riser Photo
-
New Pole Riser Installed? (CC-2c2)
-
Was drop cable installed through existing riser (DD-5a9)
-
Riser Photo
-
Was there more than 2m of Trenching FF9a1
-
Was there any Breakout & Reinstatement
-
Breakout Details
- Breakout up to 75mm thickness FF18a per sq m
- Breakout up to 150mm thickness FF18b per sq m
- Breakout over 150mm thickness FF18c per sq m
-
Breakout photos
-
Breakout photos
-
Breakout photos
-
Reinstatement Types
- Reinforced Concrete
- Unreinforced concrete
- Asphalt
- Bricks or Pavers
- Other
- Temporary
-
Reinstatement Details
- Up to 75mm FF19a1 per sq m
- 75mm to 100mm thick FF19a2 per sq m
- 100mm to 150mm thick FF19a3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to25mm thick FF19c1 per sq m
- 25mm to 50 mm thick FF19c2 per sq m
- 50mm to 75mm thick FF19c3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Detail
- Remove 80mm thickness of Bricks or Pavers (FF19d1)
- Lay 80mm thickness of Bricks or Pavers (FF19d2)
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Turf FF19e1
- Kerb and Channel FF19e2
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Cold Mix FF19f1 up to 25mm thick per sq m
- Cold Mix FF19f2 25 to 50mm thick per sq m
- Cold Mix FF19f3 50 to 75 mm thick per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to 100mm FF19b1 per sq m
- 100 to 150mm thick FF19b2 per sq m
- 150 to 200mm thick FF19b3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Did you provide a conduit entry into an Asbestos pit (FF-4c)
-
Asbestos Photos
-
Bandit Strapping CC2f each band
-
Bandit Strapping Photos
-
Was There Any Blockages?
-
Type of Blockage
- High Pressure Spit Water EE14f each
- Low Pressure Hose EE14g each
- Network Blockage up to 50mm EE14a1 each
- Locate Buried Pits FF15
-
Buried Pit before
-
Buried Pit After
-
Spit water flush photo
-
Low pressure flush photo
-
Sequence Number
-
Blockage Before
-
Blockage Repaired
-
Blockage Area After
-
Was there any E/O
-
E/O Length EE14c1
-
Additional length photo
-
E/O Depth EE14E1
-
Additional depth photo
-
Was there any Breakout & Reinstatement
-
Breakout Details
- Breakout up to 75mm thickness FF18a per sq m
- Breakout up to 150mm thickness FF18b per sq m
- Breakout over 150mm thickness FF18c per sq m
-
Breakout photos
-
Breakout photos
-
Breakout photos
-
Reinstatement Types
- Reinforced Concrete
- Unreinforced concrete
- Asphalt
- Bricks or Pavers
- Other
- Temporary
-
Reinstatement Details
- Up to 75mm FF19a1 per sq m
- 75mm to 100mm thick FF19a2 per sq m
- 100mm to 150mm thick FF19a3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to25mm thick FF19c1 per sq m
- 25mm to 50 mm thick FF19c2 per sq m
- 50mm to 75mm thick FF19c3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Detail
- Remove 80mm thickness of Bricks or Pavers (FF19d1)
- Lay 80mm thickness of Bricks or Pavers (FF19d2)
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Turf FF19e1
- Kerb and Channel FF19e2
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Cold Mix FF19f1 up to 25mm thick per sq m
- Cold Mix FF19f2 25 to 50mm thick per sq m
- Cold Mix FF19f3 50 to 75 mm thick per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to 100mm FF19b1 per sq m
- 100 to 150mm thick FF19b2 per sq m
- 150 to 200mm thick FF19b3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
PCD Testing and Final Photos
-
PCD installed
-
After photo open
-
PCD installed in an accessible area
-
PCD Strength Photo
-
High Frequency 743 MHz PCD Reading
Lead-in construction
-
Lead-in construction type
Underground Lead-in Details
-
Your Lead-in Length has exceeded 40m please ensure RG11 is installed.
-
Cable Type
-
What type of Lead-in was required on site?
-
Sequence Number
-
Lead-in Area Before
-
Lead-in Work During
-
Lead-in After
-
Was Lead-in over 40m?
-
Was there more than 20m of Trenching in OTR inside the customers property?
-
Was there more than 2 metres of trenching in OTR required from the property boundary to the Network pit?
-
Was there any Non-Trenching Methods used?
-
Was there any Rock
-
Rock Photos
-
Sequence Number
-
Sequence Number
-
Groundomat Photo
-
Groundomat Distance Photo
-
Establishment Charge (FF-12g2)
-
Sequence Number
-
Boring Photo
-
Boring Distance Photo
-
Establishment Charge (FF-12g1)
-
Was there any Breakout & Reinstatement
-
Breakout Details
- Breakout up to 75mm thickness FF18a per sq m
- Breakout up to 150mm thickness FF18b per sq m
- Breakout over 150mm thickness FF18c per sq m
-
Breakout photos
-
Breakout photos
-
Breakout photos
-
Reinstatement Types
- Reinforced Concrete
- Unreinforced concrete
- Asphalt
- Bricks or Pavers
- Other
- Temporary
-
Reinstatement Details
- Up to 75mm FF19a1 per sq m
- 75mm to 100mm thick FF19a2 per sq m
- 100mm to 150mm thick FF19a3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to25mm thick FF19c1 per sq m
- 25mm to 50 mm thick FF19c2 per sq m
- 50mm to 75mm thick FF19c3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Detail
- Remove 80mm thickness of Bricks or Pavers (FF19d1)
- Lay 80mm thickness of Bricks or Pavers (FF19d2)
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Turf FF19e1
- Kerb and Channel FF19e2
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Cold Mix FF19f1 up to 25mm thick per sq m
- Cold Mix FF19f2 25 to 50mm thick per sq m
- Cold Mix FF19f3 50 to 75 mm thick per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to 100mm FF19b1 per sq m
- 100 to 150mm thick FF19b2 per sq m
- 150 to 200mm thick FF19b3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Did you provide a conduit entry into an Asbestos pit (FF-4c)
-
Asbestos Photos
-
Was a pit required to be installed over existing conduit (FF-2b1)?
-
Sequence Number
-
Was P50 trenching required on site?
-
Sequence Number
-
Was a new pit required to be installed (FF-1b1)?
-
Was There Any Blockages?
-
Type of Blockage
- High Pressure Spit Water EE14f each
- Low Pressure Hose EE14g each
- Network Blockage up to 50mm EE14a1 each
- Locate Buried Pits FF15
-
Buried Pit before
-
Buried Pit After
-
Spit water flush photo
-
Low pressure flush photo
-
Sequence Number
-
Blockage Before
-
Blockage Repaired
-
Blockage Area After
-
Was there any E/O
-
E/O Length EE14c1
-
Additional length photo
-
E/O Depth EE14E1
-
Additional depth photo
-
Was there any Breakout & Reinstatement
-
Breakout Details
- Breakout up to 75mm thickness FF18a per sq m
- Breakout up to 150mm thickness FF18b per sq m
- Breakout over 150mm thickness FF18c per sq m
-
Breakout photos
-
Breakout photos
-
Breakout photos
-
Reinstatement Types
- Reinforced Concrete
- Unreinforced concrete
- Asphalt
- Bricks or Pavers
- Other
- Temporary
-
Reinstatement Details
- Up to 75mm FF19a1 per sq m
- 75mm to 100mm thick FF19a2 per sq m
- 100mm to 150mm thick FF19a3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to25mm thick FF19c1 per sq m
- 25mm to 50 mm thick FF19c2 per sq m
- 50mm to 75mm thick FF19c3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Detail
- Remove 80mm thickness of Bricks or Pavers (FF19d1)
- Lay 80mm thickness of Bricks or Pavers (FF19d2)
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Turf FF19e1
- Kerb and Channel FF19e2
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Cold Mix FF19f1 up to 25mm thick per sq m
- Cold Mix FF19f2 25 to 50mm thick per sq m
- Cold Mix FF19f3 50 to 75 mm thick per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to 100mm FF19b1 per sq m
- 100 to 150mm thick FF19b2 per sq m
- 150 to 200mm thick FF19b3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Was Lead-in over 40m?
-
Was There Any Blockages?
-
Type of Blockage
- High Pressure Spit Water EE14f each
- Low Pressure Hose EE14g each
- Locate and Repair Lead-in Pipe 20mm MM8a1 each
- Y Joiner used MM8a2 per Y joiner
- Network Blockage up to 50mm EE14a1 each
- Locate Buried Pits FF15
-
Buried Pit before
-
Buried Pit After
-
Spit water flush photo
-
Low pressure photo
-
Sequence Number
-
Blockage Before Photo
-
Blockage Repair Photo
-
Blockage Area After Photo
-
Was there any Breakout & Reinstatement
-
Breakout Details
- Breakout up to 75mm thickness FF18a per sq m
- Breakout up to 150mm thickness FF18b per sq m
- Breakout over 150mm thickness FF18c per sq m
-
Breakout photos
-
Breakout photos
-
Breakout photos
-
Reinstatement Types
- Reinforced Concrete
- Unreinforced concrete
- Asphalt
- Bricks or Pavers
- Other
- Temporary
-
Reinstatement Details
- Up to 75mm FF19a1 per sq m
- 75mm to 100mm thick FF19a2 per sq m
- 100mm to 150mm thick FF19a3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to25mm thick FF19c1 per sq m
- 25mm to 50 mm thick FF19c2 per sq m
- 50mm to 75mm thick FF19c3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Detail
- Remove 80mm thickness of Bricks or Pavers (FF19d1)
- Lay 80mm thickness of Bricks or Pavers (FF19d2)
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Turf FF19e1
- Kerb and Channel FF19e2
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Cold Mix FF19f1 up to 25mm thick per sq m
- Cold Mix FF19f2 25 to 50mm thick per sq m
- Cold Mix FF19f3 50 to 75 mm thick per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to 100mm FF19b1 per sq m
- 100 to 150mm thick FF19b2 per sq m
- 150 to 200mm thick FF19b3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Sequence Number
-
Before Photo
-
Y Joiner Installed
-
Area After Photo
-
Was there additional metres above 2m required as part of a LIC extension (MM-6b1)?
-
Was there any Breakout & Reinstatement
-
Breakout Details
- Breakout up to 75mm thickness FF18a per sq m
- Breakout up to 150mm thickness FF18b per sq m
- Breakout over 150mm thickness FF18c per sq m
-
Breakout photos
-
Breakout photos
-
Breakout photos
-
Reinstatement Types
- Reinforced Concrete
- Unreinforced concrete
- Asphalt
- Bricks or Pavers
- Other
- Temporary
-
Reinstatement Details
- Up to 75mm FF19a1 per sq m
- 75mm to 100mm thick FF19a2 per sq m
- 100mm to 150mm thick FF19a3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to25mm thick FF19c1 per sq m
- 25mm to 50 mm thick FF19c2 per sq m
- 50mm to 75mm thick FF19c3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Detail
- Remove 80mm thickness of Bricks or Pavers (FF19d1)
- Lay 80mm thickness of Bricks or Pavers (FF19d2)
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Turf FF19e1
- Kerb and Channel FF19e2
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Cold Mix FF19f1 up to 25mm thick per sq m
- Cold Mix FF19f2 25 to 50mm thick per sq m
- Cold Mix FF19f3 50 to 75 mm thick per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to 100mm FF19b1 per sq m
- 100 to 150mm thick FF19b2 per sq m
- 150 to 200mm thick FF19b3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Sequence Number
-
Blockage Before
-
Blockage Repaired
-
Blockage Area After
-
Was there any E/O
-
E/O Length EE14c1
-
Additional length photo
-
E/O Depth EE14E1
-
Additional depth photo
-
Was there any Breakout & Reinstatement
-
Breakout Details
- Breakout up to 75mm thickness FF18a per sq m
- Breakout up to 150mm thickness FF18b per sq m
- Breakout over 150mm thickness FF18c per sq m
-
Breakout photos
-
Breakout photos
-
Breakout photos
-
Reinstatement Types
- Reinforced Concrete
- Unreinforced concrete
- Asphalt
- Bricks or Pavers
- Other
- Temporary
-
Reinstatement Details
- Up to 75mm FF19a1 per sq m
- 75mm to 100mm thick FF19a2 per sq m
- 100mm to 150mm thick FF19a3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to25mm thick FF19c1 per sq m
- 25mm to 50 mm thick FF19c2 per sq m
- 50mm to 75mm thick FF19c3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Detail
- Remove 80mm thickness of Bricks or Pavers (FF19d1)
- Lay 80mm thickness of Bricks or Pavers (FF19d2)
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Turf FF19e1
- Kerb and Channel FF19e2
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Cold Mix FF19f1 up to 25mm thick per sq m
- Cold Mix FF19f2 25 to 50mm thick per sq m
- Cold Mix FF19f3 50 to 75 mm thick per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to 100mm FF19b1 per sq m
- 100 to 150mm thick FF19b2 per sq m
- 150 to 200mm thick FF19b3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
PCD Testing and Final Photos
-
PCD installed
-
After photo open
-
PCD installed in an accessible area
Aerial Lead-In Details
-
Your Lead-in Length has exceeded 40m please ensure RG11 is installed.
-
Cable Type
-
Lead-In Photo
-
Was Additional Span Required
-
Was there E/O installation of new coaxial drop in-span required (HFC-9a2)?
-
In-span coaxial drop Photo
-
Was there E/O for additional spans of aerial drop HFC-9a3?
-
Additional Span Photos
-
New House Riser Installed?
-
Riser Type Installed?
-
Fascia Riser Photo
-
New Pole Riser Installed? (CC-2c2)
-
Was drop cable installed through existing riser (DD-5a9)
-
Riser Photo
-
Was there more than 2m of Trenching FF9a1
-
Was there any Breakout & Reinstatement
-
Breakout Details
- Breakout up to 75mm thickness FF18a per sq m
- Breakout up to 150mm thickness FF18b per sq m
- Breakout over 150mm thickness FF18c per sq m
-
Breakout photos
-
Breakout photos
-
Breakout photos
-
Reinstatement Types
- Reinforced Concrete
- Unreinforced concrete
- Asphalt
- Bricks or Pavers
- Other
- Temporary
-
Reinstatement Details
- Up to 75mm FF19a1 per sq m
- 75mm to 100mm thick FF19a2 per sq m
- 100mm to 150mm thick FF19a3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to25mm thick FF19c1 per sq m
- 25mm to 50 mm thick FF19c2 per sq m
- 50mm to 75mm thick FF19c3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Detail
- Remove 80mm thickness of Bricks or Pavers (FF19d1)
- Lay 80mm thickness of Bricks or Pavers (FF19d2)
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Turf FF19e1
- Kerb and Channel FF19e2
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Cold Mix FF19f1 up to 25mm thick per sq m
- Cold Mix FF19f2 25 to 50mm thick per sq m
- Cold Mix FF19f3 50 to 75 mm thick per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to 100mm FF19b1 per sq m
- 100 to 150mm thick FF19b2 per sq m
- 150 to 200mm thick FF19b3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Did you provide a conduit entry into an Asbestos pit (FF-4c)
-
Asbestos Photos
-
Bandit Strapping CC2f each band
-
Bandit Strapping Photos
-
Was There Any Blockages?
-
Type of Blockage
- High Pressure Spit Water EE14f each
- Low Pressure Hose EE14g each
- Network Blockage up to 50mm EE14a1 each
- Locate Buried Pits FF15
-
Buried Pit before
-
Buried Pit After
-
Spit water flush photo
-
Low pressure flush photo
-
Blockage Before
-
Blockage Repaired
-
Blockage Area After
-
Was there any E/O
-
E/O Length EE14c1
-
Additional length photo
-
E/O Depth EE14E1
-
Additional depth photo
-
Was there any Breakout & Reinstatement
-
Breakout Details
- Breakout up to 75mm thickness FF18a per sq m
- Breakout up to 150mm thickness FF18b per sq m
- Breakout over 150mm thickness FF18c per sq m
-
Breakout photos
-
Breakout photos
-
Breakout photos
-
Reinstatement Types
- Reinforced Concrete
- Unreinforced concrete
- Asphalt
- Bricks or Pavers
- Other
- Temporary
-
Reinstatement Details
- Up to 75mm FF19a1 per sq m
- 75mm to 100mm thick FF19a2 per sq m
- 100mm to 150mm thick FF19a3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to25mm thick FF19c1 per sq m
- 25mm to 50 mm thick FF19c2 per sq m
- 50mm to 75mm thick FF19c3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Detail
- Remove 80mm thickness of Bricks or Pavers (FF19d1)
- Lay 80mm thickness of Bricks or Pavers (FF19d2)
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Turf FF19e1
- Kerb and Channel FF19e2
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Cold Mix FF19f1 up to 25mm thick per sq m
- Cold Mix FF19f2 25 to 50mm thick per sq m
- Cold Mix FF19f3 50 to 75 mm thick per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement Details
- Up to 100mm FF19b1 per sq m
- 100 to 150mm thick FF19b2 per sq m
- 150 to 200mm thick FF19b3 per sq m
-
Reinstatement photos
-
Reinstatement photos
-
Reinstatement photos
PCD Testing and Final Photos
-
PCD installed
-
After photo open
-
PCD installed in an accessible area
QA Check
-
Was a JSEA completed and signed
-
Is the PCD 150mm clear of all structures
-
Is the RF signal within Spec
-
Has the site been left clean and tidy
-
All work has been completed
-
Add signature