Information
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
POLICY
-
Are the lasted revisions of the ATA 103, JIG, or Local Authority Standards available?
-
Does the vendor maintain a file(s) of COPA HOLDING audit findings and corrective actions for a minimum of 12 calendars months and is it (are they) accessible to the auditor? (CASE 1F)
-
Does the vendor have COPA HOLDING fueling Manual to help ensure the safety and dependable flow of quality fuel to aircraft? (CASE 2-1.11)
MOBILE FUELLER LOADING RACK
-
Selective coupling (If applicable)
-
Color coding to API 1542
-
Dust caps
-
Hose and nozzle condition
-
Nozzle screen/strainer
-
Filter type. (MICRONIC, FILTER/SEPARATOR, MONITOR)
-
Date elements changed (FILTER #, DATE, INTERVAL)
-
Filter pressure differential
-
Filter sump sample
-
Fire extinguishers
-
Deadman/emergency shut-off
-
Bonding cable and clamps
MOBILE FUELLER LOADING RACK RECORDS
-
Hose records
-
Nozzle screen/strainer
-
Filter information: Checks with 7.6, 7.7, 7.8
-
Filter/separators meet API/IP 1581 (GROUP/ CLASS/CATEGORY/TYPE)
-
Filter pressure differential
-
Fire extinguishers
-
Deadman/emergency shut-off
-
Bonding cable and clamps
MOBILE FUELLERS
-
Identification of vehicle (s): (FLEET NUMBER CHECKED)
-
Vehicle condition (including leaks etc)
-
Grade plates and placards: (GRADE/ FLAMMABLE/ NO SMOKING /EMERGENCY SHUTOFF CLEAR EXIT)
-
Filter type: ( FILTER MONITOR OR FILTER/SEPARATORS)
-
Date filter changed: (DATE AND INTERVAL)
-
Filter pressure differential
-
Filter sump sample
-
Tank sump sample
-
Water defense system (If fitted)
-
Hoses and nozzles: (CONDITION, BRAND, TYPE)<br>Hoses: Date manufactured (MAX 10 YEARS)
-
Pressure control: Primary Type: ( HOSE END/ INLINE) ( Perform spot check of pressure regulation)<br> Secondary Type: (2 x Hose End/ Inline)
-
Gauges (and visible whilst refueling): (Record reading: Fueling pressure, Filter DP, Air References)
-
Deadman and emergency shut-off
-
Brake interlocks: override and seal
-
Fuel grade selective couplings
-
Nozzle screen / strainer
-
Bonding cable and clamps
-
Meter: calibration placards and seals
-
Tank interior
-
Night level shutoff system and precheck
-
Fire extinguishers: (number installed, date and interval)
-
Exhaust system, tires and brakes etc
VEHICLE RECORDS: MOBILE FUELLERS
-
Daily checks: Maintenance checks, bonding cable, fire extinguishers, meter seal, clean sample bottles, water detector kit, water check ALL points, interlock seals, deadman.
-
Weekly checks: Interlocks, bonding cables/clips (continuity check), filter differential pressures
-
Monthly check: Colour membrane filtration tests, hose visual check, hose-end strainers, deadman (opening/ closure/ volume), fire extinguisher (condition)
-
Quarterly checks: Pressure and surge controller
-
Six monthly checks: gavimetric membrane or double membrane colourimetric tests, Hose records (Record date), Pressure tested, meter calibrations, gauge accuracy test, differential pressure gauge (free movement of piston and zeroing)
-
Annual checks: Fire extinguisher inspections, fire inspections/ change (check with 9.4, 9.5, 9.6), water defence (slug valve, if applicable), FUELLER tank inspections (annually from the lid on top of the tank), FUELLER tank, draining, inspecting, cleaning (every two years)