Information
-
Customer Name
-
Customer Address
-
Conducted on
-
System Make and Model
-
System Grade (Intruder systems only)
Visit Type
-
Visit Type
- Preventative maintenace
- Corrective maintenace
-
System Type
- Intruder (BS9263&NCP120)
- CCTV (NCP104)
- Access Control (NCP109)
Intruder Alarm Preventative Maintenance Checks
-
Contract Number
Panel Checks
-
1 - Check the Installation, Location and Siting of all the equipment & Devices against the system record, the as fitted document and log book
Devices
-
Number of installed devices
-
Panel Type
-
Panel location
-
location of any other Expanders, Power supplies, keypads etc
-
2 - Have there been any changes to the property ?
-
3 - Check the satisfactory operation of all the devices including deliberately operated devies ( including tampers) - detail anything that could not be tested
-
4 - Inspect all flexible connections & ensure cable fittings & equipment are secured & adequately protected
-
5 - Check the control and PSU equipment, including connections. Complete control panel and PSU check list.
-
6 - Check remote signalling equipment for correct operation to ARC ( if applicable),
-
confirm signals checked for correct operation through to ARC
- SIA signalling
- 1 - Fire
- 2 - Panic
- 3 - Intruder
- 4- Open & Close
- 5 - Zone omitted
- 6 - Technical Fault
- 7 - Confirmed
- 8 - Tamper
- 9 - Grade 3 Engineer on site
- 10 - Grade 3 mains fail
- 11 - Site specific
- 12 - Site specific
-
Are there any signals that could not be checked, if yes please detailed in notes
-
Why was signalling not checked
-
7 - Check Line / GSM fault monitor for corect operation (if applicable)
-
8 - Check all signalling paths for correct operation
-
9 - Check that the ARC Keyholder record is correct
Add new Keyholders
-
Name of new contact
-
Phone Number of New contact
-
names of keyholders that need to be removed
-
10 - Where applicable, check with ARC all system signals are restored and the system is taken of test
-
11 - Check all audible warning & Alarm devices for correct operation.
-
12 - Check SAB activates when hold off voltage removed
-
13 - Check SAB Tamper circuit
-
14 - Check the alarm system is fully operational ( detail anything that is identified at non-functional)
-
15 - Check all Batteries ( altenative power source) in SAB's, EXP's, RKP's & Detection devices for performance
-
16- Check wireless signall strengths against those taken at time of comissioning
-
17- Entry/ Exit procedure checked
-
18- Check the exit sounds can be heard throughout the exit route
Control Panel Checks
-
1 - Aux Volts (volts)
-
2 - Bell tamp return volts (Volts)
-
3 - battery Charging Volts (volts)
-
4 - Battery Charging Current (ma)
-
5 - Global Tamper ( Ohms)
-
6 - System current normal ( Mains Off) (Ma)
-
7 - System current in Alarm ( Mains Off ) (Ma)
-
Is battery the correct size ( complete calculation as follows: System current normal X 15 + System current in Alarm )
-
Battery size installed
-
Are there any concerns from the control panel checks
Power supplies on the system
-
Are there any additional power supplies on the system
PSU Checks
-
1 - Aux Volts (volts)
-
2 - Bell tamp return volts (Volts)
-
3 - battery Charging Volts (volts)
-
4 - Battery Charging Cuurent (ma)
-
5 - Global Tamper ( Ohms)
-
6 - System current normal ( Mains Off) (Ma)
-
7 - System current in Alarm ( Mains Off ) (Ma)
-
Is battery the correct size ( complete calculation as follows: System current normal X 15 + System current in Alarm )
-
Battery size installed
-
Are there any concerns from the PSU checks
CCTV Preventative Maintenance checks
-
Contract Number
-
Check the number and type of cameras, including lenses, are per the specification and any amendments.
-
Check indicators are working correctly.
-
Check warning labels are still in place.
-
Check all cables and conduit are properly supported, undamaged and showing no signs of wear.
-
Check for sound physical fixings of all equipment including loosening or corrosion of supports and fixings including towers and brackets.
-
Check all glands and seals on external equipment.
-
Check the image quality of each camera against the reference images obtained during commissioning.
-
Covers and housings have been removed and interiors cleaned where necessary.
-
Check all automatic and remote control camera functions are satisfactory and that camera movement and fields of view are free from obstruction.
-
Operation of all monitoring, switching, recording and store equipment is satisfactory.
-
Function of all interfaces with alarms is satisfactory including correct triggering of alarms.
-
Operation of on-board / supplementary lighting is satisfactory.
-
Image retention still meets requirements specified
-
Logs are functioning correctly
-
All system software and firmware patches and upgrades are up to date
-
Check that the performance of the system continues to meet the agreed specification & User requirements
Access Control Maintenance Checks
-
Contract Number
-
The installation, location and siting of all equipment and devices against the<br>as-fitted document
-
The operation of all equipment is satisfactory
-
All flexible connections & Physical connections ok
-
The normal and standby power supplies(where fitted), correctly functioning
-
The control equipment is functioning in accordance with your designed procedures, check locks , readers, request to exits, emergency release mechanisms, fire interfaces
-
The operation of any warning device in the system ok
-
The correct operation of all system security functions is ok
-
System application and operating software is up to date with the<br>latest security patches and critical updates installed, If it is not practicable to update during the maintenance agreement with the customer should be sought to conduct at a convenient time.
-
Record current versions
-
Verify customer responsibilities have been carried out, and inform the<br>customer of any required corrective actions (I.E door closers not functioning correctly)
-
14 - Preventative Maintenance checks completed and system left in full working order
-
Provide details as to why the system has not been left in working order
-
Take a photo of the system in its current operation mode
-
Take a photo of the system in its normal operation mode
Corrective Call details
-
Contract Number
-
Reported fault
-
Tyep of signalling
- Redcare/GSM
- DC
- Dualcom
- Audible only / APP / Keyholder only
-
Any evidence photos prior to fixing fault ( ie builders damage/water damage etc)
-
cause of callout:
-
Further details and actions carried out
-
Any further Action required
-
Detail further action needed
-
System Reset
-
Method of resetting
-
Charge for call (£)
-
Amount (£)
-
Date & Time call recieved
-
Date/Time arrived on site
-
Time on site
-
Travel time
-
Material Costs (£)
-
Parts Used (list all)
-
The system has been left in full working order ( take photo of keypad in Day mode)
-
Provide details as to why the system has not been left in working order and/or any temprory or permenant disconnections made
Sign off
-
Where completion of any of the tests listed above are impracticable then any tests not completed must be recorded and agreed by the customer
-
Detail any checks/areas that have not be tested as part of this maintenance and the reason
-
Any additional works or quotes required
-
Provide details for quote required
-
Time arrived
-
Time departed
-
Engineers Name & Signature
-
Customer Name & Signature