Title Page
-
Conducted on
-
Prepared by
-
Location
-
Substation Exterior Photo
-
Wind Farm Present Output in MW
-
Weather During Inspection
-
Temperature at Start of Inspection in Celcius
-
Main Gate Closed and Locked
-
Fence Condition in Entire condition
-
Fence Grounds connected and in GOOD Condition
-
Clear of Erosion along fence perimeter
-
89-LK1 Main Disconnect Pole
-
89-LK1 - Pole, Structure and Supports in Good Condition
-
89-LK1 - Insulators in Good Condition
-
89 LK1- Motorized Switch Assembly in GOOD Condition and Attached with PIN
-
89 LK1- Switch Box Closed and Locked
-
89 LK1- Grounds and Matt at Base of Pole
-
89-LM1 Main Disconnect Pole
-
89 LM1- Pole, Structure and Supports in GOOD Condition
-
89 LM1- Insulators in Good Condition
-
89 LM1- Motorized Switch Assembly in Good Condition with PIN attached
-
89 LM1- Switch Enclosed Closed and Locked
-
89 LM1- Grounds and Matt at Base of Pole
-
Kent Pad Mount at Metering Enclosure- Good Condition
-
Kent Pad Mount at Metering Enclosure- Access Door Closed and Locked
-
Kent Pad Mount at Metering Enclosure- Bollard in Good Condition
-
Macleod Pad Mount Metering Enclosure- Overall Condition GOOD
-
Kent Pad Mount at Metering Enclosure- Clear of Any OIL leaks
-
Macleod Pad Mount Metering Enclosure- Access Doors Closed and Locked
-
Macleod Pad Mount Metering Enclosure- Bollard in GOOD Condition
-
SG-K1 Pad Mount Vista Switch- Clear of any erosion around Perimeter
-
SG-M1 Pad Mount Vista Switch-Enclosure Closed and Locked
-
SG-K1 Pad Mount Vista Switch- Ground in Good Condition
-
SG-K1 Pad Mount Vista Switch- Bollard in GOOD Condition
-
SG-M1 Pad Mount Vista Switch-Ground in GOOD Condition
-
SG-M1 Pad Mount Vista Switch- Bollard in GOOD Condition
-
JB-K2 Junction Box- Enclosure Closed and Locked
-
JB-K2 Junction Box- Clear of any Erosion around Perimeter
-
JB-K2 Junction Box- Bollard in GOOD Condition
-
JB-M1 Junction Box- Enclose Closed and Locked
-
JB-M1 Junction Box- Clear of any Erosion around perimeter
-
JB-M1 Junction Box-Ground in GOOD Condition
-
JB-M1 Junction Box- Bollard in GOOD Condition
-
JB-M4 Junction Box- Enclose Closed and Locked
-
JB-M4 Junction Box- Clear of any Erosion around perimeter
-
JB-M4 Junction Box- Ground in GOOD Condition
-
JB-M4 Junction Box-Bollard in Good Condition
-
JB-M4 Junction Box- Clear of any Erosion around perimeter
-
E-House Control Room- Access Doors Closed and Locked
-
E-House Control Room- Exterior of Building- Clear with No Damage
-
E-House Control Room-Clear of Erosion around perimeter
-
E-House Control Room-Grounds in GOOD Condition
-
E-House Control Room- GFCI Receptacles in working Condition
-
E-House Control Room- Interior of Building in GOOD Condition
-
E-House Control Room-Heating/Cooling Systems Working
-
E-House Control Room-First Aid Kit Available
-
E-House Control Room-Fire Extinguishers Checked
-
E-House Control Room-Emergency Lightening TESTED and passed on Batteries
-
E-House Control Room- Fire Shield Panel is Alarm Free and Operational
-
E-House Control Room- Clear of Any Burnt Smells
-
E-House Control Room- Clear of ANY Relay Alarms
-
E-House Control Room- Eye wash Station Check for Expiration and is Full near Kent and Macloed Battery Charging Station
-
E-House Control Room- Clear of Any Control Relay Alarms
-
Kent Schweitzer Panel
-
Macloed Schweitzer Panel
-
Kent Battery Charging Voltage
-
Kent Battery Voltage- Battery 1
-
Kent Battery Voltage- Battery 2
-
Kent Battery Voltage- Battery 3
-
Kent Battery Voltage-Battery 4
-
Kent Battery Voltage-Battery 5
-
Kent Battery Voltage- Battery 6
-
Kent Battery Voltage- Battery 7
-
Kent Battery Voltage- Battery 8
-
Kent Battery Voltage- Battery 9
-
Kent Battery Voltage- Battery 10
-
Macloed Battery Charging Voltage
-
Macloed Battery Voltage- Battery 1
-
Macloed Battery Voltage- Battery 2
-
Macloed Battery Voltage- Battery 3
-
Macloed Battery Voltage- Battery 4
-
Macloed Battery Voltage- Battery 5
-
Macloed Battery Voltage- Battery 6
-
Macloed Battery Voltage- Battery 7
-
Macloed Battery Voltage- Battery 8
-
Macloed Battery Voltage- Battery 9
-
Macloed Battery Voltage- Battery 10
-
Select date
-
Add signature
-
Scada Main Panel
-
Scada UPS
-
Fire Shield Panel
-
Eyewash Station
-
Metering Enclosure Boxes
-
Substation PPE
-
Interior - Control Room
-
Interior - Breaker Area