Title Page

  • Site conducted

  • Conducted on

  • Prepared by

  • Location

Entry

  • MIN. 950mm CLEAR DOORWAY 5mm MAX. TOLLERANCE BETWEEN SURFACES, 1500x1500 CLEAR SPACE EXTERNALLY

  • CUT EXISTING DOORWAY TO PROVIDE NEW 1200 WIDE FIRE RATED ENTRY DOOR TO COMPLY WITH CODES

Living Areas

  • LIVING ROOM TO HAVE A 2250mm Dia. FREE SPACE TO ENABLE EASE OF MOVEMENT

  • PROVIDE MIN.1540mm PATH OF TRAVEL & 1000mm TO REMAING SIDES FOR CIRCULATION SPACE<br>

  • PROVIDE THRESHHOLD RAMP TO SD's - RAMP UP SLAP AS REQUIRED AND NEW FLOOR COVERING OVER

  • CUT BASE OF EXTERNAL DOOR FRAME TO CLEAR FLOOR OVERLAY

  • PROVISIONAL SPACE FOR HOME AUTOMATION HUB ALL WIRING PROVIONS <br>OR POWER AND AUTOMATION TO BE RETROFITED AS REQUIRED AND PELMET/BULKHEADS PROVIDED WHERE NEEDED

  • PROVIDE HOIST TRACK SYSTEM OVER FIXED AS PER ENGINEERS SPEC. SYSTEM TYPE TBC

  • PROVIDE DROP DOWN GRAB RAILS IN LEIU OF WALL REINFORCMENT AS REQUIRED FOR LHA ASSESSMENT

  • ENSURE ALL DOORWAYS ARE MIN. 900mm CLEAR DOORWAY

  • ENSURE ALL ACCESSIBLE ROOMS ARE - 5mm MAX. TOLLERANCE BETWEEN SURFACES

  • ENSURE - MIN. 1200mm CLEAR PASSAGWAYS

  • ARE - WC TO HAVE 900mm CLEAR WIDTH & 1200mm CLEAR CIRCULATION SPACE IN FRONT CLEAR OF DOOR SWING

  • - PROVIDE SLIP RESISTANT FLOORING THOUGHOUT AND FEATURE A LEVEL TRANSITION BETWEEN SURFACES<br>(a min. 5mm vertical tollerance is allowable if beveled or rounded)

  • - ALL LIGHT SWITCHES TO BE 900-1100mm Above FFL HORIZONTALLY ALIGNED WITH DOOR HANDLES AT ENTRANCE TO A ROOM

  • - ALL LIGHT AND POWER SWITCHES TO BE ROCKER ACTION, TOGGLE OR PUSH PAD AND RECOMMENDED WIDTH OF 35mm.

  • - DOORS TO HAVE HARDWARE INSTALLED AT 900-100mm ABOVE FFL.

  • - DOORS TO HAVE LEVEL OR D-PULL STYLE HARDWARE

  • - All EXTERNAL DOORS TO BE ACCESSABLE BY WHEELCHAIR, PROVIDE THRESHOLD RAMP WHERE REQUIRED

  • - PROVIDE POWER SUPPLY TO ALL DOORS AND WINDOWS (BLINDS), FOR RETROFIT OF AUTOMATION AS NESSESSARY

Kitchen

  • REMOVE EXISTING KITCHEN AND PROVIDE NEW TO COMPLY WITH 'LHA/NDIS' REQ.

  • - KITCHEN & LDY TO HAVE FLOORING LAID UNDER CABINTRY TO ALLOW FOR EASY REMOVAL

  • PROVIDE MIN.1550mm CLEAR SPACE IN FRONT OF KITCHEN BENCHES & APPLIANCES

  • - CONSIDERATION FOR KITCHEN SINK, COOKTOP, MEAL PREP BENCH AREA AND KEY APPLIANCES TO BE ACCESSABLE IN SEATED AND STANDING POSITIONS. PROVIDE CLEAR SPACE UNDER BENCH TO THESE AREAS WITH REMOVABLE SHELF AND DOORS WITH HINGES TO SLIDE INTO CABINTRY

  • - PROVIDE TASK LIGHTING ABOVE WORKSPACES TO KITCHEN AREA

Wet Areas

  • - SHR LOCATED IN CORNER WITH REINFORCEMENT TO WALLS FOR FUTURE GRABRAILS

  • - SHR TO HAVE 1600mm CLEAR WIDTH & 1400mm CLEAR CIRCULATION SPACE IN FORWARD OF THE SHR

  • - BATHRROM VANITY/HANDBASIN TO BE ACCESSABLE IN SEATED AND STANDING POSITIONS

  • - BATHROOM TO HAVE SLIP RESISTANT HOBLESS SHOWER (with screens to be easily removed at later date)

  • - BASINS AND SINKS TO HAVE LEVER OR CAPSTAN STYLE TAP HARDWARE WITH CENTRAL SPOUT.

  • - PROVIDE NOGGING & PLYWOOD SHEETING TO WC, BATH, SHR AS PER DETAILS

NDIS 'HIGH PHYSICAL SUPPORT' UPGRADES

  • - All AS PER FULLY ACCESSABLE PLUS THE FOLLOWING:

  • - STRUCTURAL PROVISION FOR CEILING HOIST

  • - ASSISTIVE TECHNOLOGY READY

  • - HEATING/COOLING AND HOUSHOLD COMMUNCATION TECNOLOGY APPROPRIATE FOR THE NEEDS OF THE RESIDENT

  • - EMERGENCY POWER SOLUTIONS TO CATER FOR A MIN. 2Hrs OUTAGE WHER THE WALFARE PARTICIPANT IS AT RISK

  • - 950mm Min. CLEAR OPENING WIDTH DOORS TO ALL HABITABLE ROOMS

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.