Has job site been left in a safe, tidy and professional manner?
-
Has EU been made aware of approximate reinstatement times?
-
Has the asbuilt been followed? If not has the asbuilt been changed?
-
Is wall riser straight & attached with 2 saddles?
-
Does all trenching met appropriate standards? I.E 300mm cover on private property 450mm cover in the network?
-
If any pit upgrades have occurred have these been done to the correct standards?
-
If required have all pits been labelled correctly?
-
If ACM tap in has been completed is this to depth and been rendered?
-
Are spigots to depth?
-
Are spigots flush?
-
Has cables been tagged correctly?
-
Has cable been plugged into the correct multi port and port?
-
Has the network been re-roped?
-
If breakout has been done does this meet standards I.E straight cuts, all spray back cleaned up?
-
Does LIC placement meet required specifications?<br>(Not directly below meter box, minimum 300 from power, 1500mm from any gas source, PCD able to fully open)
-
Has site been cleaned up properly? <br>(Especially grass raked up)
-
Reinstatement complete to a satisfactory standard?
-
Does the EU have any additional comment regarding the install
-
Is the EU happy with the works that have been carried out?
-