Title Page
-
Indian Lodge Inspection
-
March 1, 2016
-
Personnel
Grounds
Grounds
-
Proper grading drainage away from house.
-
No evidence of standing water.
-
Down spout drainage directed away from house.
-
No leaks from septic tank or leech field.
-
Yard, landscaping, trees and walkways in good condition.
-
No branches or bushes touching house.
-
Exterior structures (fences, sheds, decks, retaining walls, detached garages) in good condition, no evidence of term it damage or rotted wood.
-
Driveways, patios, entrance landings in good condition, and pitched away from structure.
-
Railings on stairs and decks are adequate and secure.
-
Overhead electrical lines are kept free of trees, tree limbs and bushes.
-
Exterior electrical panel is labeled and has no open slots or missing breakers.
-
Exterior receptacles are GFCI protected.
-
Exterior receptacles are protected from the weather.
-
Exterior faucets are equipped with back flow prevention devices.
-
Additional comments.
Structure
Structure
-
Ridge and fascia board lines appear straight and level.
-
Sides of building appears straight, not bowed or sagging.
-
Windows and door frames appear square (especially bowed Windows)
-
Visible foundation is in good condition-appears straight, plumb, with no significant cracks.
-
Additional comments.
Exterior Surfaces
Exterior Surfaces
-
Adequate clearance between ground and wood siding materials (6" minimum); no wood to earth contact.
-
Siding: no cracking, curling, loose, rot, or decay.
-
Masonry veneers: no cracks in joints, no broken, spalling or flaking components.
-
Vinyl or aluminum siding: no dents, damage, bowing, or loose siding.
-
No vines in the surface of the structure.
-
Exterior paint or stain: no flaking or blisters.
-
No abnormal stains on exterior of structures.
-
Additional comments.
Windows, doors and wood trim
Windows, Doors and Wood Trim
-
Joints around frame are caulked.
-
Wood frames and trim pieces are secure, no cracks rot or decay.
-
No broken glass (window or storm pane) or damaged screens, no broken double paned, insulated window seals.
-
Storm windows or thermal glass used.
-
Additional comments.
Roof
Roof
-
Composite shingles: no curling, no cupping, no loss of granulation particulate, no broken, damaged or missing shingles, no more than two layers of roofing.
-
Wood shingles or shake: no mold, rot or decay, no cracked/ broken/ missing shingles, no curling.
-
Flat roofs: no obvious patches, no cracks or splits, minimal blisters/"alligatoring" and wrinkles, no silt deposits (indicates proper drainage), sealed tar and flashings.
-
Flashing around all roof penetrations.
-
No evidence of excess roofing cement/tar/caulk.
-
Soffits and fascia: no decay, no stains.
-
Exterior venting for eave area: vents are clean and not painted over.
-
Gutters: no decay or rust, joints sealed, attached securely to structure, no bending or sagging, no sections of gutter or downspout missing, gutters clean, no mud deposits.
-
Chimneys: straight, properly flashed, no evidence of damaged bricks or cracked joints, mortar/cement cap in good condition.
-
Additional comments.
Attic
Attic
-
No stains on underside of roofing, especially around roof penetrations.<br>
-
No evidence of decay or damage to structure.
-
Sufficient insulation and properly installed insulation (faced insulation moisture barrier is installed closest to the heated area of the house).
-
Adequate ventilation, clear path into attic for air entering through soffit vents, adequately sized gable end louvers, all mechanical ventilation operational.
-
No plumbing, exhaust or appliance vents terminate in attic.
-
No open electrical splices.
-
Stair access to attic is in working order with no missing or loose pieces.
-
Additional comments.
Interior rooms and hallways
Interior Rooms and Hallways
-
Floors, walls and ceilings appear straight plumb and level.
-
No stains on floors, walls, or ceiling.
-
Flooring materials in good condition.
-
No significant cracks in walls or ceiling.
-
Windows and exterior doors operate easily and latch properly, no broken glass, no sashes painted shut, no decay, Windows and door have weather stripping, "weep holes" installed.
-
Interior doors operate easily and latch properly, no damage or decay, no broken hardware.
-
Paint, wall covering, and paneling in good condition.
-
Wood trim installed well and in good condition.
-
Lights and switches operate properly.
-
Electrical outlets test properly (spot check)
-
Additional comments.
Bedroom 1
Bedroom 1
-
Floors, walls and ceilings appear straight plumb and level.
-
No stains on floors, walls, or ceiling.
-
Flooring materials in good condition.
-
No significant cracks in walls or ceiling.
-
Windows and exterior doors operate easily and latch properly, no broken glass, no sashes painted shut, no decay, Windows and door have weather stripping, "weep holes" installed.
-
Interior doors operate easily and latch properly, no damage or decay, no broken hardware.
-
Paint, wall covering, and paneling in good condition.
-
Wood trim installed well and in good condition.
-
Lights and switches operate properly.
-
Electrical outlets test properly (spot check)
-
Additional comments.
Bedroom 2
Bedroom 2
-
Floors, walls and ceilings appear straight plumb and level.
-
No stains on floors, walls, or ceiling.
-
Flooring materials in good condition.
-
No significant cracks in walls or ceiling.
-
Windows and exterior doors operate easily and latch properly, no broken glass, no sashes painted shut, no decay, Windows and door have weather stripping, "weep holes" installed.
-
Interior doors operate easily and latch properly, no damage or decay, no broken hardware.
-
Paint, wall covering, and paneling in good condition.
-
Wood trim installed well and in good condition.
-
Lights and switches operate properly.
-
Electrical outlets test properly (spot check)
-
Additional comments.
Bedroom 3
Bedroom 3
-
Floors, walls and ceilings appear straight plumb and level.
-
No stains on floors, walls, or ceiling.
-
Flooring materials in good condition.
-
No significant cracks in walls or ceiling.
-
Windows and exterior doors operate easily and latch properly, no broken glass, no sashes painted shut, no decay, Windows and door have weather stripping, "weep holes" installed.
-
Interior doors operate easily and latch properly, no damage or decay, no broken hardware.
-
Paint, wall covering, and paneling in good condition.
-
Wood trim installed well and in good condition.
-
Lights and switches operate properly.
-
Electrical outlets test properly (spot check)
-
Additional comments.
Kitchen
Kitchen
-
Exhaust filters are clean with no accumulation of lint and grease.
-
Working exhaust fan that is vented to the exterior of building.
-
GFCI protection for electrical outlets within 6' of sink.
-
Dishwasher: drains properly, no leaks, baskets door spring operates properly.
-
No leaks in pipes under sink.
-
Floor in cabinet under sink solid, no stains or decay.
-
Water flow in sink adequate.
-
No excessive rust or deterioration on garbage disposal or waste pipes.
-
Built in appliances operate properly.
-
Cabinets in good condition: doors and drawers and hardware operate properly.
-
Additional comments.
Bathroom 1
Bathroom 1
-
Working exhaust fan that doesn't terminate in attic space.
-
Plumbing fixtures function correctly.
-
Adequate flow and pressure at all fixtures.
-
Sink, tub and shower drain properly.
-
Plumbing and cabinet floor under sink is in good condition.
-
If sink is metal, it shows no signs of rust, overflow drain doesn't leak.
-
Toilet operates properly.
-
Toilet stable, no rocking, no stains around base.
-
Caulking in good condition inside and outside of the tub and shower area.
-
Tub or shower tiles secure, wall surface solid.
-
No stains or evidence of past leaking around base of bath or shower.
-
GFCI protection for electrical outlets within 6' of water source.
-
Additional comments.
Bathroom 2
Bathroom 2
-
Working exhaust fan that doesn't terminate in attic space.
-
Plumbing fixtures function correctly.
-
Adequate flow and pressure at all fixtures.
-
Sink, tub and shower drain properly.
-
Plumbing and cabinet floor under sink is in good condition.
-
If sink is metal, it shows no signs of rust, overflow drain doesn't leak.
-
Toilet operates properly.
-
Toilet stable, no rocking, no stains around base.
-
Caulking in good condition inside and outside of the tub and shower area.
-
Tub or shower tiles secure, wall surface solid.
-
No stains or evidence of past leaking around base of bath or shower.
-
GFCI protection for electrical outlets within 6' of water source.
-
Additional comments.
Miscellaneous
Miscellaneous
-
Smoke and carbon dioxide detectors where required by local ordinances - inside and immediately outside each bedroom.
-
Fire extinguishers are available and have been inspected annually, as required.
-
Stair handrails are placed where needed and are in good condition.
-
Automatic garage door opener operates properly, stops properly for obstacles.
-
Clothes dryers are properly vented to the exterior with rodent resistant vent flaps and ducts are free of accumulated lint.
-
Additional comments.
Mechanical Room
Mechanical Room
-
No evidence of moisture.
-
Exposed foundation; no stains, no major cracks, no flaking, no efflorescence.
-
HVAC operates on heat and cooling settings.
-
Visible structural wood: no sagging, no damage, no decay, no stains, no damage from insects, sills attached to foundation with anchor bolts.
-
HVAC filter is in place and is clean.
-
Breakers are labeled as to what they control and breaker boxes have no open slots or missing breakers.
-
Additional comments.
Crawl Space
Crawl Space
-
Adequately vented on exterior.
-
Insulation on exposed water supply, waste and vent piped.
-
Insulation between crawl space and heated areas, installed with vapor barrier towards heated area.
-
No evidence of insect damage.
-
Underpinning in good shape.
-
Additional comments.
Plumbing
Plumbing
-
Water heater: no signs of rust, vented properly, equipped with T&P valve, sized to produce adequate quantities of hot water for the number of bedrooms in the house.
-
Visible pipes: no damage, no evidence of leaks, no signs of stains on materials near pipes; drain pipes slope slightly down towards outlet to septic/sewage system.
-
Additional comments.