Information
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
PPE & Safe Work Practices
-
PPE correctly worn per posting and task
-
Safety shoes (Required unless doctors note on file)
-
Hearing protection (if required)
-
Gloves (if required)
-
Other required PPE?
Lifting Devices
-
Rail, Hoist, and lifting devices have rated capacity
-
Inspection tag located on hoist pendant
-
Can operator explain daily inspection performed as listed on inspection tag?
-
Inspect chain slings for wear and damage.
-
Do fiber slings have capacity and inspection tags
-
Do below the hook devices (furnace lifting trees, furnace baskets etc.) have capacity and inspection tags
-
Suspended loads must be attended
-
Suspended loads must never be lifted over employees
Safety Shower / Eye Wash Station
-
Located where acids / bases (corrosives) used.
-
Inspected weekly, not blocked
Emergency Exits
-
Aisles and emergency exits not blocked
Electrical
-
Voltage indicated on electrical control enclosures, power cabinets,, junction boxes etc.
-
Arc Flash label present on electrical control enclosures, power cabinets, junction boxes etc.
-
Clearance in front of electrical enclosures36" (0-150v) and 42" (151-600v)
-
Chords are free from frays and damage
-
Electrical enclosures are secured with wire, mechanical interlock, sealed, bolted, screwed, tie wrapped or padlocked requireing the use of a key or tool to gain entry
-
Extension cords only allowed for temporary situations <90 days. must be inspected annually
-
GFCI's required on portable electric tools and in areas where wetness or damage to cord is possible
-
Are knockout plugs present on all electrical enclosures
PIV's
-
Daily walk around being completed prior to each shift used.
-
PIV Badge - Training & Medical Exam current
-
Seatbelt used whenever forklift operated
Flammable Cabinets
-
Only flammable liquids in cabinet (no paper, wood or plastic stored in cabinet)
-
Cabinets undamaged
-
No more than 3 cabinets within 100 square feet
Environmental
-
Stacks and drains labeled
-
POG - Clean & labeled correctly
-
POG lid latched
-
POG sign form e507 posted
-
No more than 55 gallons of hazardous waste stored at POG
-
Are day cans emptied one daily
Machine Guarding
-
Machines anchored (if machine can walk or move)
-
Is point of operation (grinding wheel, etc.) protected such that inadvertent contact is prevented?
-
Flywheels, gears, shafts, pulleys, belts, gears, sprockets, chains and couplings guarded to protect employees
-
E-stop button present
Walking / Working surfaces
-
Abrupt changes in elevation shall not exceed 1/4 inch
-
Free from nails and gaps
Fire Extinguishers
-
Monthly Inspection completed / Verify completely charged
Confined space
-
Marked with proper signage (permit required sign or non permit required sign
HAZCOM
-
All containers labeled. (Original container with Manufacturers Label or secondary container with HMIS label)
-
Does employee know how to access an MSDS for a chemical used?
Lockout / Tagout
-
Is machine specific energy control procedure present (owner M. Cline)
-
Are LOTO labels present
Blending Tools
-
Are safety latches present on all compressed air powered grinding tools
Compressed Air Nozzles
-
Are nozzles labeled as OSHA compliant. (regulate air pressure to 30psi or less)
Compressed Gas Cylinder Storage
-
Are cylinders identified with a durable label that clearly identifies the cylinder contents and gives a brief description of the potential hazard?
-
Cylinders secured with chain, lab strap or hard stock device located on the upper one third of the cylinder
-
Nesting methods for storage are prohibited. Acceptable means of storage include individual chains or straps, holding racks, cylinder carts etc.
-
Flammable gasses shall be stored at least 20 feet from oxidizers and any other source of ignition or separated by an approved firewall
ACE
-
Monitor turned on?
-
Linearity chart current?
-
And on light on at gateway
-
Waterfall chart on schedule or up to day
-
Takt time posted / understood?
-
Daily walk around signed off?
-
6s audits & newspaper are current
-
Observe if standard work is being followed
-
Area clean & organized (less than 1 day of dirt)?
-
Aisles and emergency exits not blocked?
Do the employees know: (Interview a few people)
-
Takt time?
-
Which processes are certified?
-
Where the skilled matrix is located?
-
When is thier ACE meeting or QCPC meeting?
-
Who enters the TB's
-
Where their Value Stream Map is located
-
Machine class (A, B, or C)
-
What do they do if they find a problem (QCPC ticket and notify lead)
-