Identification of Machine
-
Make / Model / Identification evidence of machine
-
Photo
-
Use
Guarding
-
Are Light Curtains, Laser Scanners or ESPE of any type being used as machine guarding?
-
Is there current mechanical guarding in place on machinery?
-
Is guarding ZERO ACCESS i.e. sufficient to prevent access to the moving parts?
-
Describe what additional controls are in place, if any?
-
Are the gaps adequate to prevent accidental access to dangerous moving parts?
-
Describe what additional controls are in place, if any?
-
Are there any unguarded nip points?
-
Describe what additional controls are in place, if any?
-
Is a specialist tool required to remove existing guarding?
-
Is the tool stored away from machinery?
-
Is there a permit system in place prior to the removal of guarding?
-
Are all electrical fixtures covered?
-
Is there a need for integrated guarding (eg two handed operation due to exposed dangerous components while in use)?
-
Describe what complementary safety controls are in place?
-
Are AS6157 compliant walkways,platforms and guard rails used to prevent access to dangerous parts?
-
Details of possible improvements according to AS6157.
-
Is there suitable access for servicing eg removable section to service, maintenance, removable panels to allow access to adjust bolts etc?
-
Are guards secured eg mounting bolts tightened, grills secured?
-
Are safety isolation lock out devices (LOTO) fitted and tested as operational?
Findings
Additional Information and comments
Recommendations
Auditee
-
Add signature
Validation of Safety Related Parts of Control System (SRPCS)
SRPCS Validtaion
-
What type of controls are used on this machinery?
- Fixed Guarding
- Interlocked Guarding
- Type 4 Safety Light Barriers (Res > 50mm)
- Type 4 Safety Light Curtains (Res <50mm)
- Safety Laser Scanner (Cat3,PLd)
- Type 2 Safety Light Curtains (Res <50mm)
- Type 2 Safety Light Barriers (Res > 50mm)
- RFID Guard Switches
- Magnetic Safety Switches
- Two Hand Control type IIIC (upto Cat 4,PLe)
- Hold To Run (Enable Switches)
- Slow Speed Safety Jog Control
- Safety Mats or Edges
- Solenoid Locking Safety Switches
- Key Exchange Mechanical Latches
- Safety Relays
- Safety Configurable Relays (LVL acc. AS4024.1503:2014
- Safety PLC (AS62061 SIL3 compliant)
- STO enabled Drive
- Emergency Stop
- Safety Contactors
- Safety Interlocks
- Lanyard Emergency Stop
- Safe Speed Detection
- Standstill Monitoring (Back EMF, or Proximity Devices)
- Safe Camera System
-
Have all reasonable measures been taken to place the Safety Devices far enough away from the hazards to ensure machine comes to a stop before reaching the hazard? See standards such as AS4024:2801 for guidance
-
Please detail your assumptions and how what you have done is equal to or better than the current state of knowledge - i.e. AS4024:2801
Validation Testing - Fault Analysis of SRPCS Devices Used
-
Emergency Stops & Lanyard Switches
- Cross Short Test between input Channels (Cat 3 & 4)
- Input Channel Lost Signal (removal of one channel)
- 24vDC intrusion
- Earth Fault or 0v test where applicable
-
Validation Test Results
-
Details of failure and remedial action required.
-
Interlocks (RFID, Magnetic, Mechanical and Solenoid Locking)
- Cross Short Test between input Channels (Cat 3 & 4)
- Input Channel Lost Signal (removal of one channel)
- 24vDC intrusion
- Earth Fault or 0v test where applicable
-
Validation Test Results
-
Details of failure and remedial action required.
-
Light Curtains, Grids, Scanners, Cameras and Single beam Switches
- Cross Short Test between input Channels (Cat 3 & 4)
- Input Channel Lost Signal (removal of one channel)
- 24vDC intrusion
- Earth Fault or 0v test where applicable
-
Validation Test Results
-
Details of failure and remedial action required.
-
Is Muting of Light Curtains Used?
-
Muting of Light Curtains, Grids & Scanners
- Test Concurrent or Sequential Muting
- Test Override is not permanent
- Test Muting Lamp Feedback (where fitted)
- Light Curtains Revert to normal operation post mute
-
Validation Test Results
-
Details of failure and remedial action required.
-
RESET Circuit Testing and Testing of Safety Contactor Feedback
- Removal of Feedback to Safety Relay / PLC
- Short Circuit of Feedback Auxiliary Contact
- Short Circuit of RESET Switch (Anti Tie Down Test)
-
Validation Testing Results
-
Details of Failure and remedial action proposed.
-
Validation of Safety Software - Configurable Relays and Safety PLCs - refer to AS4024.1503:2014 & AS62061:2005
- Check for Program Safety Errors
- Test Fuctions with Dynamic Testing (viewing running program whilst performing validation test)
- Peer Reviewed Program
- No toggle bits or short circuit links left in program
- No Safety PLC or Configurable Relay Used
-
Safety Relay Types Used
- Dual input Safety Relays
- Safety Relays with Time delays
- Safe Speed or Standstill relays
- Safety Relays for Solenoid Locking
- Safe Jog Speed Relays
- Safety Expansion Relays
-
Validation Test Results
-
Validation Test Results
-
Details of failure and remedial action required.
-
Complementary Safety Measures Used?
- Two Hand Controls
- Enable Switches - Hold To Run
- Safe Speed Monitoring
- Standstill Monitoring
- Foot Switches
- None Used
-
Validation Testing Results
-
Details of Solutions and Testing i.e EN574 for Two Hand Controls.
Additional Information
-
Additional Information - any specific solutions not considered by this validation
-
Person Completing Report
-
Select date
-
Add signature