Information
-
On-Site Cabinet Inspection:
-
Client / Site
-
Conducted on
-
Prepared by
Case Installation Details
-
Select date
-
Cabinet Installation Information
Cabinet Information
-
Epta Serial Number:
-
Cabinet type:
-
Fascia fitted without damage?
- Front Fascia Ok
- Left Hand Fascia Ok
- Left Hand Fascia Corner Ok
- Right Hand Fascia Ok
- Right Hand Fascia Corner Ok
- LH Fascia End Stop Ok
- RH Fascia End Stop Ok
- Front Fascia Damaged
- Left Hand Fascia Damaged
- Left Hand Fascia Corner Damaged
- Right Hand Fascia Damaged
- Right Hand Fascia Corner Damaged
- LH Fascia End Stop Damaged
- RH Fascia End Stop Damaged
-
If 'No' provide details:
-
Fascia colour and finish quality correct and acceptable?
-
Bumper to specification and fitted without damage?
- Front Bumper Ok
- LH Bumper Ok
- RH Bumper Ok
- LH Bumper Corner Ok
- RH Bumper Corner Ok
- Front Bumper Damaged
- LH Bumper Damaged
- RH Bumper Damaged
- LH Bumper Corner Damaged
- RH Bumper Corner Damaged
-
If 'No' provide details:
-
Bumper End Caps screwed into position (where applicable)?
- LH screwed in position
- RH screwed in position
- Not applicable
- Not fitted
- LH not screwed in position
- RH not screwed in position
-
If 'No' provide details:
-
End Walls fitted and in good condition?
- LH Solid Ok
- LH Glazed Ok
- RH Solid Ok
- RH Glazed Ok
- Not Applicable
- Not Fitted
- LH Solid Damaged
- LH Glazed Damaged
- RH Solid Damaged
- RH Glazed Damaged
-
If 'No' provide details:
-
Night blind(s) fitted and fully retracting within c15 seconds (where applicable)?
-
If 'No' provide details:
-
Canopy lighting correctly fitted?
-
If 'No' provide details:
-
Doors working and correctly fitted?
-
If 'No' provide details:
-
Door damper(s) operating correctly (where applicable)?
- All dampers OK
- RH bay LH door OK
- RH bay RH door OK
- Ctr bay LH door OK
- Ctr bay RH door OK
- LH bay LH door OK
- LH bay RH door OK
- Not applicable
- RH bay LH door U/S
- RH bay RH door U/S
- Ctr bay LH door U/S
- Ctr bay RH door U/S
- LH bay LH door U/S
- LH bay RH door U/S
-
If 'No' provide details:
-
Door(s) sitting square in frame (where applicable)?
- All dampers OK
- RH bay LH door OK
- RH bay RH door OK
- Ctr bay LH door OK
- Ctr bay RH door OK
- LH bay LH door OK
- LH bay RH door OK
- Not applicable
- RH bay LH door U/S
- RH bay RH door U/S
- Ctr bay LH door U/S
- Ctr bay RH door U/S
- LH bay LH door U/S
- LH bay RH door U/S
-
If 'No' provide details:
-
Perspex Divider(s) fitted and correctly affixed without damaged?
- LH Fitted Ok
- RH Fitted Ok
- LH Damaged
- RH Damaged
- Not Applicable
- Not Fitted
-
If 'No' provide details:
-
Weir Risers fitted and in good condition (where applicable)?
-
If 'No' provide details:
-
Back Panels fitted and in good condition?
-
If 'No' provide details:
-
Ticket Strip fitted without damage?
-
If 'No' provide details:
-
Honeycomb fitted without damage?
-
If 'No' provide details:
-
Sufficient clearance under cabinet to fit condensate pump. ( i.e. c93mm clearance)
-
Drainage trap(s) and cradle(s) fitted without damage?
-
Plinth(s) on-site without damage?
- Correct item(s) on site Ok
- Correct item(s) fitted Ok
- Wrong item(s) on site
- Correct item(s) damaged
- Not applicable
- Part(s) missing
-
If anything other than 'Correct item(s) undamaged' provide details:
Supporting Photographs
-
Front of cabinet
-
LH side of cabinet (where applicable)
-
RH side of cabinet (where applicable)
-
Rear of cabinet (where applicable)
-
Drainage outlet(s) and cradle(s) (where applicable)
Sign-Off
-
Inspected on behalf of George Barker Refrigeration (Leeds) Ltd.@
-
Received and signed by
-
On behalf of