Title Page
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
-
PEERLESS JOB NAME
-
INSTALLER/CUSTOMER NAME - COMPANY
TYPICAL SUBSILL RECEPTOR EXTERIOR
-
WEEPS DRAIN OPEN AND CLEAR OF DEBRIS
-
FREE OF GAPS IN WEATHERPROOFING AROUND SUBSILL/RECEPTOR THAT ARE CLEARLY NOTICEABLE
-
WEEP HOODS INSTALLED
-
IS THE EXPOSED JOINT OF MALE/FEMALE JOINT LOCATION SEALED AND TOOLED
-
IF VERTICLE MULLIONS ARE USED, WAS THE MULLION SET IN POOL OF SEALANT AND TOOLED, AND SEALANT APPLIED NEXT TO THE VERTICLE BULB AND ANY SQUISH OUT TOOLED
TYPICAL RECEPTOR SUBSILL
-
ARE JAMBS SQUARE AND NOT BOWED
-
IS SUBSILL RECEPTOR SET SQUARE AND PLUMB WITHIN THE OPENING
-
END DAMS SEALED CORRECTLY
-
RECEPTOR SET IN POOL OF SILICONE ON SUBSILL AND TOOLED CLEAN
-
WAS SEALANT APPLIED IN SEALANT TRACK OF SUBSILL FOR THE WINDOW TO SIT IN
-
WAS RECEPTOR CLIP SET IN POOL OF SEALANT ON THE SUBSILL AND 8" UP ON THE CLIP
-
WAS SEALANT TOOLED AROUND THE PEREMITER OF RECEPTOR CLIP TO SUBSILL JOINT
MALE - FEMALE WINDOW JOINTS
-
IS THE EXPOSED JOINT OF MALE/FEMALE JOINT LOCATION SEALED AND TOOLED
-
WAS A CONTINOUS BEAD OF SEALANT APPLIED ON BOTH MALE LEGS ON THE LEADING AND TRAILING EDGES OF MALE LEGS
VERTICAL 3 PIECE MULLION
-
WAS PRESSURE PLATE SET IN POOL OF SEALANT ON THE SUBSILL AND TOOLED
-
WAS SEALANT APPLIED ALONG SIDE OF BULB VINYL 8" UP FROM BOTTOM AND COVER INSTALLED
-
WAS SEALANT APPLIED TO BOTTOM OF COVER AND TOOLED AROUND THE PROFILE
NAIL FIN FLASHING
-
WAS SEALANT APPLIED TO FULL PERIMETER OF THE BACKSIDE OF WINDOW FIN
H-MULLION W/O SUBSILL
-
WAS MULL CLIP ANCHORED THROUGH RECEPTOR AND INTO SUBSTRATE TO CARRY THE LOAD OF THE H-MULL
-
WAS H-MULL PROFILE SEALED BEFORE FASTENING THE END DAM
-
IS H-MULL FACE SEALED AT THE BUTT JOINT TO RECEPTOR AND TOOLED
-
IS WINDOW SET (BOTH TOP AND BOTTOM WINDOW) INTO A CONTINOUS BEAD OF SEALANT IN BOTH INTERIOR AND EXTERIOR TRACKS
ZERO MULLIONS
-
SEALANT IS APPLIED 8" UP FROM BOTTOM ALONG MIDDLE OF MULLION
-
CONTINOUS BEAD OF SEALANT IS APPLIED TO EDGES OF ZERO MULL AND TOOLED CLEANLY AT WINDOW TO WINDOW JOINT.
WINDOW WITH TRIM SETS - NO SUBSILL OR RECEPTOR
-
WAS WINDOW SET ON U-SHIMS WITH BACKER ROD UNDER THE EXTERIOR LEG
-
WAS SEALANT APPLIED OVER TRIM FASTENERS UNDER TRIM CAP
-
SEALANT APPLIED AND TOOLED AROUND ENTIRE EXTERIOR OF WINDOW TO WALL JOINT
PANNING
-
MITERED EDGES OF PANNING PROFILES SEALED WHILE ASSEMBLY AND SQUEEZE OUT TOOLED CLEANLY
-
SEALANT FACE APPLIED ON THE JAMB TO SILL JOINT OF THE PANNING, TOOLED CLEANLY
-
PANNING INSTALLED SQUARE AND PLUMB, USING CUSTOMER SHIPS FOR PROPER SPACING
-
SEALANT APPLIED TO AREAS WHERE FASTENERS ARE USED TO ATTACH PANNING TO WALL CONDITION
-
SEALANT APPLIED TO EXTERIOR JOINTS OF THE PANNING SET TO WALL CONDITION, AND TOOLED CLEANLY
-
SEALANT APPLIED TO INSIDE FACE OF PANNING FOR THE WINDOW TO COMPRESS AGAINST AND ANY SQUISH OUT TOOLED CLEANLY