Title Page

  • Document No.

  • Audit Title

  • Client / Site

  • Conducted on

  • Prepared by

  • Location
  • Personnel

  • PEERLESS JOB NAME

  • INSTALLER/CUSTOMER NAME - COMPANY

TYPICAL SUBSILL RECEPTOR EXTERIOR

  • WEEPS DRAIN OPEN AND CLEAR OF DEBRIS

  • FREE OF GAPS IN WEATHERPROOFING AROUND SUBSILL/RECEPTOR THAT ARE CLEARLY NOTICEABLE

  • WEEP HOODS INSTALLED

  • IS THE EXPOSED JOINT OF MALE/FEMALE JOINT LOCATION SEALED AND TOOLED

  • IF VERTICLE MULLIONS ARE USED, WAS THE MULLION SET IN POOL OF SEALANT AND TOOLED, AND SEALANT APPLIED NEXT TO THE VERTICLE BULB AND ANY SQUISH OUT TOOLED

TYPICAL RECEPTOR SUBSILL

  • ARE JAMBS SQUARE AND NOT BOWED

  • IS SUBSILL RECEPTOR SET SQUARE AND PLUMB WITHIN THE OPENING

  • END DAMS SEALED CORRECTLY

  • RECEPTOR SET IN POOL OF SILICONE ON SUBSILL AND TOOLED CLEAN

  • WAS SEALANT APPLIED IN SEALANT TRACK OF SUBSILL FOR THE WINDOW TO SIT IN

  • WAS RECEPTOR CLIP SET IN POOL OF SEALANT ON THE SUBSILL AND 8" UP ON THE CLIP

  • WAS SEALANT TOOLED AROUND THE PEREMITER OF RECEPTOR CLIP TO SUBSILL JOINT

MALE - FEMALE WINDOW JOINTS

  • IS THE EXPOSED JOINT OF MALE/FEMALE JOINT LOCATION SEALED AND TOOLED

  • WAS A CONTINOUS BEAD OF SEALANT APPLIED ON BOTH MALE LEGS ON THE LEADING AND TRAILING EDGES OF MALE LEGS

VERTICAL 3 PIECE MULLION

  • WAS PRESSURE PLATE SET IN POOL OF SEALANT ON THE SUBSILL AND TOOLED

  • WAS SEALANT APPLIED ALONG SIDE OF BULB VINYL 8" UP FROM BOTTOM AND COVER INSTALLED

  • WAS SEALANT APPLIED TO BOTTOM OF COVER AND TOOLED AROUND THE PROFILE

NAIL FIN FLASHING

  • WAS SEALANT APPLIED TO FULL PERIMETER OF THE BACKSIDE OF WINDOW FIN

H-MULLION W/O SUBSILL

  • WAS MULL CLIP ANCHORED THROUGH RECEPTOR AND INTO SUBSTRATE TO CARRY THE LOAD OF THE H-MULL

  • WAS H-MULL PROFILE SEALED BEFORE FASTENING THE END DAM

  • IS H-MULL FACE SEALED AT THE BUTT JOINT TO RECEPTOR AND TOOLED

  • IS WINDOW SET (BOTH TOP AND BOTTOM WINDOW) INTO A CONTINOUS BEAD OF SEALANT IN BOTH INTERIOR AND EXTERIOR TRACKS

ZERO MULLIONS

  • SEALANT IS APPLIED 8" UP FROM BOTTOM ALONG MIDDLE OF MULLION

  • CONTINOUS BEAD OF SEALANT IS APPLIED TO EDGES OF ZERO MULL AND TOOLED CLEANLY AT WINDOW TO WINDOW JOINT.

WINDOW WITH TRIM SETS - NO SUBSILL OR RECEPTOR

  • WAS WINDOW SET ON U-SHIMS WITH BACKER ROD UNDER THE EXTERIOR LEG

  • WAS SEALANT APPLIED OVER TRIM FASTENERS UNDER TRIM CAP

  • SEALANT APPLIED AND TOOLED AROUND ENTIRE EXTERIOR OF WINDOW TO WALL JOINT

PANNING

  • MITERED EDGES OF PANNING PROFILES SEALED WHILE ASSEMBLY AND SQUEEZE OUT TOOLED CLEANLY

  • SEALANT FACE APPLIED ON THE JAMB TO SILL JOINT OF THE PANNING, TOOLED CLEANLY

  • PANNING INSTALLED SQUARE AND PLUMB, USING CUSTOMER SHIPS FOR PROPER SPACING

  • SEALANT APPLIED TO AREAS WHERE FASTENERS ARE USED TO ATTACH PANNING TO WALL CONDITION

  • SEALANT APPLIED TO EXTERIOR JOINTS OF THE PANNING SET TO WALL CONDITION, AND TOOLED CLEANLY

  • SEALANT APPLIED TO INSIDE FACE OF PANNING FOR THE WINDOW TO COMPRESS AGAINST AND ANY SQUISH OUT TOOLED CLEANLY

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.