Title Page

  • Pre-Concrete ITP

  • Site Address

  • Concrete location. (e.g. Garage slab, Level 2 slab etc..)

  • Conducted on

  • Prepared by

  • Pour Description

Concrete supply & specifications

  • Concrete on site time booked

  • Concrete supplier

  • Concrete mix ordered

  • Quantity/ Volume ordered - M3

  • Any additive or accelerator?

  • Test required?

  • Has concrete supplier been advised how trucks should enter the site?

  • Are traffic management services required?

  • Pump washout area confirmed to pump operator?

Personnel

  • Formwork Contractor

  • Steelworker

  • Pump Contractor

  • Concrete Finishing Contractor

  • Engineer

  • Certifier

  • Electrician

  • Plumber

Pre-Concrete Placement

  • Have all dimension been checked against the architectural and engineer's drawings and RFI's that pertain to this area?

  • Are all Hobs/Upstands/downturns formed per the drawings?

  • Check set-downs for wet areas (min 50mm)

Suspended Slab

  • Ensure formwork deck for suspended slabs are set to the right height

  • Ensure formwork A-frames have cross bracers both sides

  • Check rebates sizes and positions under sliding doors

  • Have all minimum clear cover requirements been achieved?

  • Has all reo and mesh been checked against Engineer drawings?

  • Has the Engineer attended site to inspect and sign off?

  • Has the engineer requested/authorised photos in lieu of site visit?

  • Has the Certifier attended site to inspect and sign off?

  • Has termite protection been installed?

  • Have adequate supports (chairs) been installed so that reo and wire mesh remain in position during the pour?

  • Is the vapour barrier installed correctly

  • Have dowels been checked for proper placement?

  • Are starter-bars at correct centers and alignment?

  • Stormwater, drainage and hydraulic pipework installed, retained and checked?

  • Plumber's ITP Received?

  • Are all electrical conduits and fitments installed and Electrician's ITP Received?

  • Are Floor wastes all set and at the proper RL for falls?

  • Are there any sleeves, recesses or misc items that need to be placed?

  • Has expansion material been placed at all the specified locations.

  • Is formwork clean and free of debris/rust/scaling ?

  • Pictures - Include all areas and at least 10 photos

  • Acceptance Signatures:

  • Signature- Site Manager

  • Signature Engineer

  • Signature - Certifier

  • Signature Formworker

  • Signature

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.