Title Page
Pullkey Audit
-
Document No.
-
Audit Title
-
Client / Site
-
Address / Location
-
Conducted on
-
Prepared by
Visual Inspection
-
Serial Number
-
Part Number
-
Conveyor name (eg CV-043)
-
Pullkey tag name (eg C/T 10, Linestand 10, CV-10 etc)
-
General condition
Switch Operators
-
Inspect RUN/STOP operator
-
Inspect ISOLATE REQUEST operator
Ingress Protection
-
Inspect fascia gasket
-
Inspect switch actuator gaskets
-
Inspect LED bezels
-
Inspect pull rod boots (inc cable tie)
-
Inspect enclosure for any signs of ingress failings (eg weld fractures etc)
Verify Pullkey Operation
-
Operate RUN/STOP SWITCH and verify:<br><br>RUN ~> STOP<br>Verify status LED (B-line) changes from slow flags to fast flash<br>Verify stop is reported correctly at iMAC controller/SCADA<br><br>STOP ~> RUN<br>Verify status LED (B-line) changes from fast flash to slow flash<br><br>
-
Operate LEFT PULL ROD and verify:<br><br>RUN ~> STOP<br>Verify status LED (B-line) changes from slow flags to fast flash<br>Verify stop is reported correctly at iMAC controller/SCADA<br><br>STOP~> RUN<br>Verify status LED (B-line) changes from fast flash to slow flash<br><br>
-
Operate RIGHT PULL ROD and verify:<br><br>RUN ~> STOP<br>Verify status LED (B-line) changes from slow flags to fast flash<br>Verify stop is reported correctly at iMAC controller/SCADA<br><br>STOP ~> RUN<br>Verify status LED (B-line) changes from fast flash to slow flash<br><br>
Sign
Summary
-
Pullkey Condition
Signature
-
I hereby declare that an actual audit took place and all results are accurate at time of auditing