Information
-
Train ID
-
Locomotive Number
-
Conducted on
-
Location
-
Auditor
Inspection Items
-
1. Are horn and bell inspected for damage and defects. Per W-2102? <br>WARNING: DO NOT ACTIVATE HORN WHEN EMPLOYEES ARE IN CLOSE PROXIMITY. INSURE ALL ARE IN SAFE AREA WHEN HORN IS ACTIVATED, AND ONLY IN AREAS WHERE HORNS ARE PERMITTED TO BE ACTIVATED.
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
2. Are all (lead and trail) 2 Way Telemetry Equipment (HTD) tested and functionality verified per SMR X-2400-18 and W-2122?
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
3. Are crossing warning lights being checked for physical defects and proper operation? W-2137
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
4. Are speed indicators in lead and trail units being checked for speed indications as units are being moved and units with indicator problems qualified? W-2139
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
5. Are safety control devices being checked for proper operation, with wheels chocked or hand brake on? Following time out of safety control devices, did the brake pipe pressure reduce at a service rate and did the brakes apply on all locomotives in the consist? W-2141
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
6. Are jumper cables between units firmly secured in receptacles and cable hangers properly fastened? Are spare jumper cables secured in dummy receptacles? W-2175
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
7. Are one of each type MU hose coupled between units in consist, properly cut in and free of any air leaks? W-2176
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
8. Are cross boards in proper position and safety chains fastened with 6" maximum slack to ensure continuous barrier? W-2177
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
9. Are all sanders operational from controls of leading unit in consist and correctly aligned? Are forward and reverse directions checked for sand delivery? W-2178
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
10. Was an operational test made of the independent brake system using set-up and release? W-2179
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
11. Was an operational test made of the automatic brake system in consist by making service reduction, actuation release (bail off), further service reduction and brake release? W-2179<br>
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
12. Was brake leakage test performed on consist before dispatching? W-2179 (No more than 3 pound leakage per minute).
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
13. Was an emergency application of the brake system performed to insure automatic sanding and P.C. switches are operating properly? W-2179
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
14. Was section 1 of the Locomotive and Train Brake Test Certificate, form BTC100MT (latest revision) completed and placed on the control stand in the lead locomotive? W-2179
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
15. Is consist being checked in DB operation? Is proper number of traction motors cut in during operational check? W-2180
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
16. Is the proper number of available dynamic brake axles being calculated and annotated on section 5 of the Locomotive and Train Brake Test Certificate? W-2180
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
17. Are both front and rear headlights operating properly when turned on and both respond to dimming control from lead unit? W-2181
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
18. Are all units in consist responding to throttle movements when loading in both directions? W-2182
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
19. Is each unit in consist supplied with one each, hammer, 18" hose wrench, chisel and red flag? W-2183
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
20. Is each unit in consist supplied with a minimum of six and a maximum of twelve fusees? W-2183
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
21. Is each unit in consist supplied with one each "E" and "F" spare knuckle and properly secured? W-2183
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
22. Is each unit in consist supplied with the proper number of tags placed in torpedo compartment? W-2183<br>- 3 Non-compliance tags<br>- 3 Inoperative Dynamic Brake tags<br>- 6 Bad Order / Movement of Defective Car tags
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
23. Is each unit in consist supplied with one each Conductors car repair report, CSX form 1114EC placed with locomotive daily inspection / work report form? W-2183
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
24. Is each consist supplied with one car chain on proper holders? W-2183
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
25. Is each unit in consist supplied with 1 each spare trainline hose? W-2183
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
26. Are lead units of consist being supplied with ice if unit is equipped with an ice box? W-2183
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
27. Are lead units of consist supplied with 6 each crew packs and 6 eight oz. bottles of drinking water per crew member? W-2183
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
28. Are circuit breakers in proper position for lead/trail? W-2186 (SMR Appendix A)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
29. Are Control/FP, ER and GF switches on control stands of all trailing units in consist placed in "OFF" position? W-2186
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
30. Are all independent brake handles in "OFF" position on all trailing units? W-2186
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
31. Are all automatic brake valve handles placed in "HANDLE OFF" position on all trailing units? W-2186
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
32. Is the FRA Blue Card form and air card properly completed, signed and dated? (229.23) <br>When applicable 184 day Q sticker must be applied to Blue Form holder and Mechanical Department Log Form 480-9000007-1 must be completed.
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
33. Are all doors and windows closed on each trailing unit of consist? W-2186
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
34. Are cab heaters turned on in all trailing units of consist during the months of September through April? W-2186
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
35. Are reverser lever handles on all trailing units in consist removed and placed in proper holders? W-2186
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
36. Are all locomotives being shut down when ambient temperature is 28 degrees or above? W-2186
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
37. If unit is equipped with an APU/ERM are the following switches in the proper positions: W-2191<br>- Is APU in "Auto cycle" on the APU control cabinet?<br>- Is ERM circuit breaker closed/on?<br>- Is APU battery charger circuit breaker (on the APU) on?<br>- Is ERM status light in the cab either red or green and not flashing?
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
38. List separately any identified FRA defects not covered in this checklist.
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date