Title Page

  • Conducted for -

  • Conducted on

  • Auditor

  • Location
  • Jointers Name

  • Jointers Mates Name

  • Vehicle Registration

1. Site Preparation

  • 1.1 Does risk assessment accurately reflect site conditions?

  • Please provide Photographic evidence if possible.

  • 1.2 Does vehicle present no risk to other road users?

  • Please provide Photographic evidence if possible.

  • 1.3 Does vehicle present no risk to pedestrians?

  • Please provide Photographic evidence if possible.

  • 1.4 Has the driver completed the vehicle daily checks?

  • Please provide Photographic evidence if possible.

  • 1.5 Does vehicle offer protection from traffic?

  • Please provide Photographic evidence if possible.

  • 1.6 Are barriers in place and in good order?

  • Please provide Photographic evidence if possible.

  • 1.7 Are barriers being correctly used?

  • Please provide Photographic evidence if possible.

  • 1.8 Are all workers aware of the extent of work?

  • Please provide Photographic evidence if possible.

  • 1.9 If needed have any special requirements been identified on the work pack?

  • Requirements

2. Access & Egress

  • 2.1 Is route from van to work site free from any safety issues?

  • Please provide Photographic evidence if possible.

  • 2.2 Is Access/Egress to joint bay/work location safe ?

  • Please provide Photographic evidence if possible.

3. Cable Identification

  • 3.1 Are mains records available?

  • Please provide Photographic evidence if possible.

  • 3.2 Were mains records consulted during identification?

  • Please provide Photographic evidence if possible.

  • 3.3 Are all other electrical assets visible and identifiable?

  • Please provide Photographic evidence if possible.

  • 3.4 If any, are other utilities present free from any hazards?

  • Please provide Photographic evidence if possible.

  • 3.5 Are Pre-work cable damage checks completed?

  • Please provide Photographic evidence if possible.

4. Cable Preparation

  • 4.1 Is the correct PPE available/selected and is it being appropriately used?

  • Please provide Photographic evidence if possible.

  • 4.2 Are the correct tools available in good condition?

  • Please provide Photographic evidence if possible.

  • 4.3 Are tools being used correctly?

  • Please provide Photographic evidence if possible.

  • 4.4 Are the correct procedures for cable preparation and stripping being used?

  • Please provide Photographic evidence if possible.

  • 4.5 Are armours correct?

  • Please provide Photographic evidence if possible.

  • 4.6 Lead removal/ lifting of neutral?

  • Please provide Photographic evidence if possible.

  • 4.7 Cleaning of lead?

  • Please provide Photographic evidence if possible.

  • 4.8 Application of earths correct?

  • Please provide Photographic evidence if possible.

  • 4.9 Taping of cores correct?

  • Please provide Photographic evidence if possible.

Pre-Commissioning Testing

  • 5.1 Is the correct PPE selected and is it being properly used ?

  • Please provide Photographic evidence if possible.

  • 5.2 Is the correct test equipment being used, is it in calibration?

  • Please provide Photographic evidence if possible.

  • 5.3 Are the correct tests being completed on the main?

  • Please provide Photographic evidence if possible.

  • 5.4 Are the correct continuity & insulation tests being completed on newly installed assets?

  • Please provide Photographic evidence if possible.

6. Joint Completion

  • 6.1 Is the correct PPE selected and is it being properly used ?

  • Please provide Photographic evidence if possible.

  • 6.2 Are the correct tools selected and used for the task?

  • Please provide Photographic evidence if possible.

  • 6.3 Are Pre-connection tests completed prior to the connection?

  • Please provide Photographic evidence if possible.

  • 6.4 Is shrouding applied correct?

  • Please provide Photographic evidence if possible.

  • 6.5 Are connections made in correct order?

  • Please provide Photographic evidence if possible.

  • 6.6 Are core connectors applied correctly?

  • Please provide Photographic evidence if possible.

  • 6.7 Are connectors insulated correctly?

  • Please provide Photographic evidence if possible.

  • 6.8 Are connectors staggered correctly?

  • Please provide Photographic evidence if possible.

7. Post Commission Testing

  • 7.1 Is the correct PPE selected and is it being properly used?

  • Please provide Photographic evidence if possible.

  • 7.2 Evidence of correct use of test equipment?

  • Please provide Photographic evidence if possible.

  • 7.3 Are all relevant tests completed?

  • Please provide Photographic evidence if possible.

  • 7.4 Are all test results recorded?

  • Please provide Photographic evidence if possible.

  • 7.5 Are terminations sealed correctly and service position secured?

  • Please provide Photographic evidence if possible.

8. Work Pack Completion

  • 8.1 Are on/off times recorded accurately?

  • Please provide Photographic evidence if possible.

  • 8.2 Is the pro-forma completed correctly?

  • Please provide Photographic evidence if possible.

  • 8.3 Are the result recordings sufficient?

  • Please provide Photographic evidence if possible.

9. Site Clearance

  • 9.1 Is all redundant cable removed ?

  • Please provide Photographic evidence if possible.

  • 9.2 Are all cable stripping's removed?

  • Please provide Photographic evidence if possible.

  • 9.3 Are cables adequately protected?

  • Please provide Photographic evidence if possible.

  • 9.4 Resin bags/Rubbish removed from site?

  • Please provide Photographic evidence if possible.

  • 9.5 Is all fencing reinstated?

  • Please provide Photographic evidence if possible.

10.Are there any other notable issues/ good practice worth recording?

11.Debriefing

  • 10.1 Have the team been debriefed on the findings?

  • Any further feedback ?

  • Comments

12. Sign off and close out

  • Is this audit free from any NON-CONFORMANCES. If you have identified any non-conformances what have you done about it before leaving site.

  • Auditors Signature

  • Jointers Signature

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.