Title Page
-
Site conducted
-
Patterns
-
Foundry - DC1
-
Foundry - DC2
-
Foundry - DC3
-
Fettling
-
Conducted on
-
Prepared by
5.1 Patterns
-
Date
-
Auditee names
-
Is the area tidy, clean and organised
-
Are all patterns and coreboxes suitably identified ?
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Is storage location recorded ?
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
How are incoming patterns handled ?
-
How are any pattern work requirements documented
-
Document Control
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Does the evidence indicate that the process map is being followed
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
5.2 Sand Preparation
-
Date
-
Auditee names
-
Is the mixer area tidy, clean and organised
-
Is the laboratory area tidy, clean and organised
-
What raw materials are used
-
What raw material certification is provided by suppliers ?
-
What sand tests are carried out
-
How often are the sand tests done
-
Are actions taken if results are outside defined limits ?
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Are actions documented ?
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Do the results indicate the process is in control ?
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
When was the mixer last calibrated ?
-
Document Control
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Does the evidence indicate the process map is being followed
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
5.3 Coremaking / 5.4.1 & 5.4.3 Core Coating
-
Date
-
Auditee names
-
Is the area tidy, clean and organised
-
Is a route card available ?
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Is the corebox checked before use
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
How does the operator know how the core needs to be made ? (irons, chills etc)
-
How does the operator know when to strip the core ?
-
Does the core get inspected after stripping and what is the operator looking for ?
-
How is the core identified ?
-
How is the core coated ?
-
Are baume coating checks carried out the coating ?
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Are the baume checks within limits ?
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
How does the operator determine that the core is coated and acceptable for use ?
-
Is the route card signed off and by who ?
-
Document Control
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Does the evidence indicate that the process map is being followed
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
5.4.5 Polystyrene Pattern Coating
-
Date
-
Auditee Names
-
Is the area tidy, clean and organised
-
Is the route card available
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Check the coating type in use
-
How many coats are applied
-
What is the drying time between coats
-
What checks are made after each coat
-
Is route card signed off once coating is complete and poly released for production
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Document Control
-
Does the evidence indicate that the process map is being followed
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
5.5 Ramming
-
Date
-
Auditee Names
-
Is the area tidy, clean and organised
-
Is route card available
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Is daily plan available
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
How is the method instruction communicated
-
Is the prescribed method for the parts being rammed being followed
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
How is the strip time determined ?
-
Is pattern release being used ?
-
How is the moulding box size determined ?
-
How long is each mould allowed to cure ?
-
Document Control
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Does the evidence indicate that the process map is being followed
5.6 Moulding / 5.4.2 Mould Coating / 5.4.4 Mould Coating - Steel
-
Date
-
Auditees
-
Is the area tidy, clean and organised
-
Are route cards available
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
How are the moulds coated
-
Are baume checks carried out on the coating
-
Are baume checks within limits
-
What is the mould checked for to determine if its acceptable
-
How does the moulder know if cores are required and which cores are for which mould
-
Are cores available and acceptable
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
How are cores assembled into the mould
-
How does the moulder know if there are any special requirements (eg. ingates, filters, inoculant etc)
-
Are 2 people are involved in closing the mould to ensure correct positioning of cope on drag (observe)
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Is the mould closed and then opened to check for crush, sand etc (observe)
-
What determines whether are fixed (C-clamp) or adjustable (carver clamp) are used
-
What determines if mould weights are used and how is this communicated to the moulder
-
Is the route card signed off and by who ?
-
Document Control
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Does the evidence indicate that the process map is being followed
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
5.7 Melting & Pouring / 5.7.1 DC1 / 5.7.2 DC2/DC3
Melt Planning
-
Date
-
Auditee(s)
-
Are route cards available
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Does the melt plan match the route cards
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Does the melt plan contain the required information for furnace charges
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Are the requirements for testing defined (test bars etc)
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Is the pouring temperature defined for each pour
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
Charging, Melting & Pouring
-
Date
-
Auditees
-
Is the area tidy, clean and organised
-
Are charge weights recorded and correct to melt plan
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
What determines if Redux needs to be added and to what frequency is it added
-
Are the furnace loadcells in calibration
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Last loadcell calibration dates
-
DC2/3 only - is 0.1% pre-seed added to SG iron charges
-
Is tapping temperature recorded and in line with melt plan requirements
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Is thermal analysis sample taken and recorded (total carbon & silicon content) and in line with melt plan requirements
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
How do the melt team know the ladle treatment requirements for the melt (MgFeSi, inoculant etc)
-
Is the iron temperature checked before pouring and correct to melt plan
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Are the pyrometers and QuikLab in calibration
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Last pyrometer / QuikLab calibration dtaes
-
Is a test bar poured at the end of pouring when required
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
How is the test bar/keel block identified
-
Is a nodularity test sample poured at the end of pouring when required for SG iron
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Check the nodularity test records in the lab - are they recorded against melt code and 85% min nodularity
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
If any nodularity results are <85% what actions have been taken
-
Is a spectrometer sample cast and identified against melt code
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Is the chemistry checked using the spectrometer
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Is the spectrometer calibration checked using standard samples
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
List spectrometer standard samples in use and drift check dates for last 5 min checks
-
Are the chemistry results in line with metallurgist requirements
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Is the melt record completed and signed
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Is the route card completed and signed
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Is there any evidence that corrective actions have been required and taken as prescribed (HT, concess, scrap etc)
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
List some examples if applicable
-
Document Control
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Does the evidence indicate that the process map is being followed
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
5.8 Knockout DC1 / 5.8.1 Knockout DC2 / 5.8.2 Knockout DC3
-
Date
-
Auditees
-
Is the area tidy, clean and organised
-
Is the time from pouring to KO defined on the route card
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Is this time being followed
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Record examples
-
Is the casting visually checked at KO
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Are visually defective castings identified and segregated
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Are different material types segregated at KO (runners, feeders etc)
-
Which types of material
-
If specified on the route card, how is the temperature of the casting checked before KO
-
Is the sand recycled
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
DC1/DC3 only - is the moulding box checked for damage after KO and sent for repair if required
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Is the route card completed and signed
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Document Control
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Does the evidence indicate that the process map is being followed
- Yes
- No
- N/A
5.9 Shotblasting
-
Date
-
Auditees
-
Is the area tidy, clean and organised
-
How is the casting temperature deemed to be low enough for shotblasting
-
What determines which shotblast unit (or sub-con) will be used
-
Is the shotblast quality acceptable (typically Sa 2 1/2)
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Are visually defective castings identified and segregated at shotblasting
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Are castings shotblasted after fettling
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
How is this decided
-
Is the route card completed and signed
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Document Control
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Does the evidence indicate that the process map is being followed
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
5.10 Fettling
-
Date
-
Auditees
-
Is the area tidy, clean and organised
-
Is the route card available
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Is the casting visually inspected during fettling
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Are written instructions / visual aids / gauges / used for fettling
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Examples
-
Are defective castings segregated
-
Is HAV's monitoring of each fettling step utilising a powered tool carried out
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Is the route card completed and signed
-
Document Control
-
Does the evidence indicate that the process map is being followed
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
5.11 Finishing & Final Inspection
-
Date
-
Auditees
-
Is the area tidy, clean and organised
-
Is the route card available
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Are any other documents required (standards, specifications, drawings etc) and available
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Are part/customer specific inspection/test requirements communicated via the route card
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Are all required inspections completed
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Are non conforming parts place in quarantine
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Is the route card completed and signed
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Document Control
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Does the evidence indicate that the process map is being followed
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
5.12 Casting Painting (Internal)
-
Date
-
Auditees
-
Is the route card available
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Does the route card indicate the painting requirement
-
Check the paint and application are as required (observe)
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Is the route card completed and signed
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Document Control
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A
-
Does the evidence indicate that the process map is being followed
- Yes / OK
- No / Not OK
- Opportunity for Improvement
- NC Raised
- N/A