Title Page
Audit Details
-
Installation completed on:
-
Auditor Name:
-
Inspection conducted on:
Project Details
-
Workstream:
-
Client:
-
Project Manager:
-
Site No and Name:
-
Site Postcode:
-
Site Type:
-
Scope of Works as detailed on HOP:
-
Person in Charge of Works:
-
Other Team Members:
1. Audit Questions
-
Project:
Build
-
Have build works been carried out?
-
Has the structure been installed and aligned as per design drawings?
-
Has the anticlimb been installed to specification, and is it secure?
-
Has the fall arrest system been correctly installed according to safety specifications? (e.g. fixing elements, connection screws, cable cut correctly, plate spinning correctly, etc..)
-
Has the fall arrest system information plate been correctly stamped? (e.g. showing site number
-
Has the lightning protection for this site been correctly installed or reattached?
-
Has the cable management been installed correctly as per drawings?
-
If pull testing was part of the scope of works, has this been carried out to the required standard and evidenced in the HOP photos?
-
If a streetworks pole has been installed have the nuts been torqued correctly and evidenced in the HOP photos?
-
If installation of additional steelwork was part of the scope of works, has this been installed as per design drawings and correctly connected to the LP system?
Antennas
-
Have antennas been installed as part of the works?
-
Is the antenna the correct type as per the SCF/SDR/RDS/design drawings?
-
Do the mechanical/electrical tilts and bearings match those specified in the SCF/SDR/RDS/design drawings?
-
Are the antennas installed at the correct level (vertical/mid-point alignment) and face aligned to avoid shadowing/clipping?
-
Have the tilt brackets been installed correctly?
-
Have safety lanyards been installed correctly as per spec? (VFUK)
-
Has the Smart Bias T been installed correctly and on the correct port?
-
Have the RET leads been installed correctly?
-
Has the engineer saved the RET report correctly?
-
Are the RF warning stickers installed on all antennas as per spec?
-
Are all unused antenna ports capped?
-
Are all RF tails connected to correct ports?
Weatherproofing
-
Has weatherproofing been installed as part of the works?
-
Is the enough self amalgamating tape on the connectors?
-
Has the full connector been covered, including the heat shrink on factory made tails?
-
is the outer layer of tape tight and tidy with no flags?
Tagging
-
Has tagging and labelling been installed as part of the works?
-
Have the correct tags been installed as per spec?
-
Are all tags correctly secured?
-
Are all tags properly printed, clearly readable, and not hand written?
-
Are all cable ties cut flush?
Cable Management
-
Has cable management been installed as part of the works?
-
Is there the correct distance between studs?
-
Are there drip loops at the gland where required in spec?
-
Are there any visible defects with the gland (e.g. more than one cable per Roxtec module, visible air gaps, open glands/missing modules, etc)?
-
Have the correct size clamps been used?
-
Is there 20mm max / 2mm min left on studs?
-
Has a flat and a spring been added to all studs?
-
Where studs have been cut, have end caps been installed?
-
Is the bend radius correct as per manufacturers specification?
-
Has the engineer avoided the cables being crossed?
-
Has the engineer straightened the cables?
-
Is the correct cable management installed?
-
Have unused cables been capped at cab end/demarcation point?
-
Are the feeders terminated to the correct demarcation point?
-
Has the GPS cable been terminated correctly and presented in the correct position as per spec?
-
Have fibres been run to the correct location and are unused fibres capped, coiled, and stored correctly?
Cable Earthing
-
Has cable earthing been installed as part of the works?
-
Are there the correct number of earths for the length and route of the cables as per spec?
-
Has contact paste been applied to all stainless to copper/galvanised connections?
-
Have the earths been installed as per spec?
-
Have the earth tails been installed as straight as possible?
RRU/RRH/ERS/Combiner/MHA etc
-
Have RRUs/ERSs/RRHs/Combiners/MHAs/etc been installed as part of the works?
-
Are all units correctly earthed as per spec?
-
Have all units been installed correctly as per manufacturers guidance?
-
Have all units been installed in the correct positions set out in the design drawings?
-
If unistrut has been used for mounting equipment, have end caps been installed? (subject to spec)
-
Have the RF jumpers been connected to the correct ports?
-
Have the fibre jumpers been connected correctly?
-
If BOBs have been installed, are the internal cable management and fibre/DC connections correct?
Site Conditions
-
Has the site been left secure?
-
Has the site been left tidy with all waste removed?
-
Has a 'Paragraph 18' notice been installed and visible to the public?
-
Have any cable glands/roxtec/tray covers/etc been installed correctly?
-
Have all ducts been sealed with expanding foam?
-
Have the correct photos of the installation been taken and submitted for the HOP?
Additional Comments
-
Are there any additional quality issues on site which have not yet been identified as part of this audit?
2. Site Photos
-
Site Photos