Information
-
Conducted on
-
Prepared by
General Information
-
Job name and number
- Cameron Hospital Masonry 13-3151
- St. Marys 13-3174
- Springfield Family Ice 13-3177
- ISU Residence Hall 12-3156
- Police Crime Lab 13-3276
- Miami University 13-3270
-
Date inspected
-
Comments
Flashing check list
-
Reference Point. Column line, elevation, height, window no.
-
Is SS Drip sealed to substrate (Lintel, CMU, Concrete, Brick ledge)?
-
Add media
-
Is thru-wall flashing sealed to SS (minimum 2 beads of sealant)?
-
Add media
-
Is thru-wall flashing attached to backup wall with term bar or installed in CMU?<br>
-
Add media
-
Is Term-bar sealed to backup wall with approved sealant?
-
Add media
-
I thru-wall flashing free of dirt, defects, holes, rips, fish mouths?
-
Add media
-
Are all seams sealed with minimum 2 beads of sealant?
-
Add media
-
Are prefab outside corners, inside corners, and end dams used
-
Add media
-
If prefab is not use, is flashing folded not cut?
-
Add media
-
Are end dams at correct location (end of steel lintels)
-
Add media
-
Have you attached photos to each section?
-
Add media
Signatures
-
Inspector
-
Superintentent