Title Page
-
Site conducted
-
Conducted on
-
Prepared by (Enter First name and Surname)
-
Location
-
Supervisor
-
Crew
-
Shift
-
Today's Safety Focus is:
-
I AM FIT FOR WORK ACCORDING TO NBG GUIDELINES
-
Sign Inspection Sheet
Deposition - Northern Line
-
Is the Northern line depositing slurry?
-
Take photos to show the tailings buffer at the discharging spigots
-
Is there greater than 0.5 metre freeboard (crest to water level) at the discharging spigots?
-
Record the spigots ID that are affected
-
Tagged Valve out of Service and Updated DCS that valve is out of service
-
Informed RDA Supervisor
-
Is there greater than 0.5 metre tailings buffer (crest to beach level) at the discharging spigots?
-
Record the spigots ID that are affected
-
Tagged Valve out of Service and Updated DCS that valve is out of service
-
Informed RDA Supervisor
-
Any Spigots Open as per the Deposition Plan?
-
Reasons for not following Plan
-
Informed RDA Supervisor
-
Is this line suppose to be in service?
-
Is the slurry discharging from at least 3 spigots?
-
Toubleshoot the issue and comment
-
Are there adequate spigots open downstream of where it is discharging?
-
Toubleshoot the issue and comment
-
Is there Distressed Wildlife or Wildlife Mortality?
-
Contact Environmental Department -Processing Enviro 0419 759 721 -Mining Enviro 0409 215 019
-
Upload Photo/s
-
Estimated Cloud Cover %
-
Record Action Taken
Deposition - Southern Line
-
Is the Southern line depositing slurry?
-
Take photos to show the tailings buffer at the discharging spigots?
-
Is there greater than 0.5 metre freeboard (crest to water level) at the discharging spigots?
-
Record the spigots ID that are affected
-
Tagged Valve out of Service and Updated DCS that valve is out of service
-
Informed RDA Supervisor
-
Is there greater than 0.5 metre tailings buffer (crest to beach level) at the discharging spigots?
-
Record the spigots ID that are affected
-
Tagged Valve out of Service and Updated DCS that valve is out of service
-
Informed RDA Supervisor
-
Any Spigots Open as per the Deposition Plan?
-
Reasons for not following Plan
-
Informed RDA Supervisor
-
Is this line suppose to be in service?
-
Is the slurry discharging from at least 3 spigots?
-
Toubleshoot the issue and comment
-
Are there adequate spigots open downstream of where it is discharging?
-
Toubleshoot the issue and comment
-
Is there Distressed Wildlife or Wildlife Mortality?
-
Contact Environmental Department -Processing Enviro 0419 759 721 -Mining Enviro 0409 215 019
-
Upload Photo/s
-
Estimated Cloud Cover %
-
Record Action Taken
Deposition - Eastern Line
-
Is the Eastern line depositing slurry?
-
Take photos to show the tailings buffer at the discharging spigots?
-
Is there greater than 0.5 metre freeboard (crest to water level) at the discharging spigots?
-
Take a Photo of the Area
-
Record the spigots ID that are affected
-
Tagged Valve out of Service and Updated DCS that valve is out of service
-
Informed RDA Supervisor
-
Is there greater than 0.5 metre tailings buffer (crest to beach level) at the discharging spigots?
-
Take a Photo of the Area
-
Record the spigots ID that are affected
-
Tagged Valve out of Service and Updated DCS that valve is out of service
-
Informed RDA Supervisor
-
Any Spigots Open as per the Deposition Plan?
-
Reasons for not following Plan
-
Informed RDA Supervisor
-
Is this line suppose to be in service?
-
Is the slurry discharging from at least 3 spigots?
-
Toubleshoot the issue and comment
-
Are there adequate spigots open downstream of where it is discharging?
-
Toubleshoot the issue and comment
-
Is there Distressed Wildlife or Wildlife Mortality?
-
Contact Environmental Department -Processing Enviro 0419 759 721 -Mining Enviro 0409 215 019
-
Upload Photo/s
-
Estimated Cloud Cover %
-
Record Action Taken
Embankments
Seepage
-
Is there evidence of NEW Seepage observed?
-
Evidence of Seepage
Location
-
Enter Time and Date Seepage Identified
-
Locate the Area of Seepage
-
Take Photo/s of the area
-
Contacted RDA Supervisor
-
Contacted RDA Engineer
Erosion
-
Is there evidence of Erosion observed?
-
Evidence of Erosion
Location
-
Enter Time and Date Erosion Identified
-
Locate the Area of Erosion
-
Take Photo/s of the area
-
Contacted RDA Supervisor
-
Contacted RDA Engineer
Cracking
-
Is there evidence of Cracking observed?
-
Evidence of Cracking
Location
-
Enter Time and Date Cracking Identified
-
Locate the Area of Cracking
-
Take Photo/s of the area
-
Contacted RDA Supervisor
-
Contacted RDA Engineer
Spillway
-
Is the Freeboard at Spillway Greater than 1.0 Metre of Residue?
-
Contacted RDA Supervisor
-
Enter the Time and Date contact was made
-
Contacted RDA Engineer
-
Enter the Time and Date contact was made
-
Is Freeboard at Spillway Greater than 1.5 Metres of Water?
-
Contacted RDA Supervisor
-
Enter the Time and Date contact was made
-
Contacted RDA Engineer
-
Enter the Time and Date contact was made
LCRS and Underdrainage
Underdrainage 1 (430-PPU-001)
-
What is the Water Level Reading?
-
What is the Water Flowrate Reading?
-
Is the Pump Operational?
-
Enter the Reason the Pump is not Running
Underdrainage 2 (430-PPU-002)
-
What is the Water Level Reading?
-
What is the Water Flowrate Reading?
-
Is the Pump Operational?
-
Enter the Reason the Pump is not Running
Underdrainage 3 (Currently Xylem Hire Unit)
-
What is the Water Level Reading?
-
What is the Water Flowrate Reading?
-
What is the Totaliser Reading
-
Is the Pump Operational?
-
Enter the Reason the Pump is not Running
Eastern LCRS (430-PPU-004)
-
What is the Water Level Reading?
-
What is the Water Flowrate Reading?
-
Is the Pump Operational?
-
Enter the Reason the Pump is not Running
Residue Lines
CIL Train 1 Residue Line
-
Is there any visible leaks on pipes, flanges or vacuum breakers?
-
Identified Leaks on pipes, flanges or vacuum breakers?
Location
-
Enter Time and Date Issue Identified
-
Locate the Area of Issue
-
Take Photo/s of the area
-
Work Notification Entered?
-
Enter Work Notification Number
-
Are the Tell-tale pressure gauges indicating pressure?
-
Identified tell-tale pressure gauges indicating pressure
Location
-
Enter Time and Date Issue Identified
-
Locate the Area of Issue
-
Take Photo/s of the area
-
Work Notification Entered?
-
Enter Work Notification Number
CIL Train 2 Residue Line
-
Is there any visible leaks on pipes, flanges or vacuum breakers?
-
Identified Leaks on pipes, flanges or vacuum breakers?
Location
-
Enter Time and Date Issue Identified
-
Locate the Area of Issue
-
Take Photo/s of the area
-
Work Notification Entered?
-
Enter Work Notification Number
-
Are the Tell-tale pressure gauges indicating pressure?
-
Identified tell-tale pressure gauges indicating pressure
Location
-
Enter Time and Date Issue Identified
-
Locate the Area of Issue
-
Take Photo/s of the area
-
Work Notification Entered?
-
Enter Work Notification Number
Residue line pipeline containment bunding
-
Is the pipeline containment bunding damaged ?
-
What is the damage and where is it located?
-
Photo of damage taken?
-
Reported to supervisor?
RDA Roadways and Access
-
Are the Perimeter Roads Outside the RDA embankments in drive-able condition?<br>
-
Location of Issue
Location
-
Enter Time and Date Issue Identified
-
Locate the Area of with the issue
-
Take Photo/s of the area
-
Are the Access Ramps to the Embankments in drive-able condition?<br>
-
Location of Issue
Location
-
Enter Time and Date Issue Identified
-
Locate the Area of with the issue
-
Take Photo/s of the area
-
F1/F3 pipeline perimeter Road in drive-able condition?<br>
-
Location of Issue
Location
-
Enter Time and Date Issue Identified
-
Locate the Area of with the issue
-
Take Photo/s of the area
-
Is the Access Road from CIL in drive-able condition?<br>
-
Location of Issue
Location
-
Enter Time and Date Issue Identified
-
Locate the Area of with the issue
-
Take Photo/s of the area
Open Trenches and Drains Outside of the F1/F3 Dams
-
Is there Animal damage Present?<br>
-
Location of Issue
Location
-
Enter Time and Date Issue Identified
-
Locate the Area of with the issue
-
Take Photo/s of the area
-
Are there any washouts present?<br>
-
Location of Issue
Location
-
Enter Time and Date Issue Identified
-
Locate the Area of with the issue
-
Take Photo/s of the area
-
Are there Breaks in Windrows?
-
Location of Issue
Location
-
Enter Time and Date Issue Identified
-
Locate the Area of with the issue
-
Take Photo/s of the area
-
Are there any External Wet Spots?<br>Note - All Wet Spots are to be reported to the RDA Supervisor
-
Location of Issue
Location
-
Enter Time and Date Issue Identified
-
Locate the Area of with the issue
-
Take Photo/s of the area
-
Reported to RDA Supervisor
Catchpits
Catchpit 1
-
Are there any cracks or damage to the concrete drive in sump?
-
Work notification entered?
-
Are Water Levels Acceptable?
-
Are there any leaks, damage or hazards?
-
Are the Weir bars in place?
Catchpit 2
-
Are there any cracks or damage to the concrete drive in sump?
-
Work notification entered?
-
Is the clay liner in the catch pit disturbed
-
Report to supervisor
-
Are Water Levels Acceptable?
-
Are there any leaks, damage or hazards?
-
Are the Weir bars in place?
Catchpit 3
-
Are there holes or damage to the HDPE liner?
-
Report to supervisor
-
Work notification entered?
-
Take photo of the damage
-
Are there any cracks or damage to the concrete drive in sump?
-
Work notification entered?
-
Are Water Levels Acceptable?
-
Are there any leaks, damage or hazards?
-
Are the Weir bars in place?
-
Visual Inspection - Is there any damage to HDPE Liner?
Catchpit 4
-
Are there any cracks or damage to the concrete drive in sump?
-
Work notification entered?
-
Is the clay liner in the catch pit disturbed
-
Report to supervisor
-
Are Water Levels Acceptable?
-
Are there any leaks, damage or hazards?
-
Are the Weir bars in place?
-
Visual Inspection - Is there any damage to HDPE Liner?
Decant Facility and Access
-
Is there any wildlife in distress on the tailings dam?
-
Reported to the appropriate people
-
Are the Perimeter Roads Outside the RDA embankments in drive-able condition?<br>
-
Location of Issue
Location
-
Enter Time and Date Issue Identified
-
Locate the Area of with the issue
-
Take Photo/s of the area
-
Is there good access to the Decant Facility?
-
Location of Issue
Location
-
Enter Time and Date Issue Identified
-
Locate the Area of with the issue
-
Take Photo/s of the area
-
Is overflow pipeline & discharging area clear of excessive build up?<br>
-
Location of Issue
Location
-
Enter Time and Date Issue Identified
-
Locate the Area of with the issue
-
Take Photo/s of the area
-
Is the Decant Water clarity clear?
-
Reported to RDA Supervisor
-
Is the Pond positioned on HDPE Lined area?
-
Reported to RDA Supervisor
-
Is their any holes or damage to the HDPE liner that is visible?
-
Report the RDA construction team supervisor
-
Take of photo of the damage
-
Record the Decant Station Level % Reading
Pumping System
-
Should the Diesel Pumps be operating?
-
Any water leaks?
-
Troubleshoot and organise for repair
-
Any unusual noises, heat or vibration from diesel pumps?
-
Troubleshoot and organise for repair, add photos and notes if possible
-
Notes on issue
-
Photos
-
Why is it not operating?
-
Enter the Reason
-
Is the fire extinguisher in date, pin in place and stored correctly?
-
Alert supervisor and arrange for replacement immediately
-
Is a life ring in place, stored off the ground and with a retrieval rope in good condition?
-
Alert supervisor and arrange for replacement immediately
-
Is there a yellow spill kit bin in place, stocked and free of rubbish?
-
Cleanup any rubbish, notify your supervisor and arrange for restocking of spill kit
-
Is there rubbish around or is the work area untidy?
-
Remove of any rubbish from area and dispose of correctly.
Toe Well - Saddle Dam 1E
-
Should the Toe Well be operating?
-
Record Water Level (m)
-
Record Totaliser Reading (m3)
-
Enter the Time of Totaliser Reading
-
Any water leaks?
-
Troubleshoot and organise for repair
-
Any unusual noises, heat, vibrations or leaks from Generator?
-
Troubleshoot and organise for repair, add photos and notes if possible
-
Notes on issue
-
Photos
-
Does it look like there is sufficient discharge of water while pumps are operating?
-
Troubleshoot and organise for repair
-
Why is it not operating?
-
Enter the Reason
-
Do all Generator electrical leads look in good condition and have an in date electrical tag?
-
Alert supervisor and arrange for inspection and tagging immediately.
-
Is the fire extinguisher in date, pin in place and stored correctly?
-
Alert supervisor and arrange for replacement immediately
-
Is there a yellow spill kit bin in place, stocked and free of rubbish?
-
Cleanup any rubbish, notify your supervisor and arrange for restocking of spill kit
-
Is there rubbish around or is the work area untidy?
-
Remove of any rubbish from area and dispose of correctly.
Toe Well - Saddle Dam 3W
-
Should the Toe Well be operating?
-
Record Water Level (m)
-
Record Totaliser Reading (m3)
-
Enter the Time of Totaliser Reading
-
Any water leaks?
-
Troubleshoot and organise for repair
-
Any unusual noises, heat, vibrations or leaks from Generator?
-
Troubleshoot and organise for repair, add photos and notes if possible
-
Notes on issue
-
Photos
-
Does it look like there is sufficient discharge of water while pumps are operating?
-
Troubleshoot and organise for repair
-
Why is it not operating?
-
Enter the Reason
-
Do all Generator electrical leads look in good condition and have an in date electrical tag?
-
Alert supervisor and arrange for inspection and tagging immediately.
-
Is the fire extinguisher in date, pin in place and stored correctly?
-
Alert supervisor and arrange for replacement immediately
-
Is there a yellow spill kit bin in place, stocked and free of rubbish?
-
Cleanup any rubbish, notify your supervisor and arrange for restocking of spill kit
-
Is there rubbish around or is the work area untidy?
-
Remove of any rubbish from area and dispose of correctly.
Toe Well - Saddle Dam 3E
-
Should the Toe Well be operating?
-
Record Water Level (m)
-
Record Totaliser Reading (m3)
-
Enter the Time of Totaliser Reading
-
Any water leaks?
-
Troubleshoot and organise for repair
-
Any unusual noises, heat, vibrations or leaks from Generator?
-
Troubleshoot and organise for repair, add photos and notes if possible
-
Notes on issue
-
Photos
-
Does it look like there is sufficient discharge of water while pumps are operating?
-
Troubleshoot and organise for repair
-
Why is it not operating?
-
Enter the Reason
-
Do all Generator electrical leads look in good condition and have an in date electrical tag?
-
Alert supervisor and arrange for inspection and tagging immediately.
-
Is the fire extinguisher in date, pin in place and stored correctly?
-
Alert supervisor and arrange for replacement immediately
-
Is there a yellow spill kit bin in place, stocked and free of rubbish?
-
Cleanup any rubbish, notify your supervisor and arrange for restocking of spill kit
-
Is there rubbish around or is the work area untidy?
-
Remove of any rubbish from area and dispose of correctly.
Toe Well - Saddle Dam 4
-
Should the Toe Well be operating?
-
Record Water Level (m)
-
Record Totaliser Reading (m3)
-
Enter the Time of Totaliser Reading
-
Any unusual noises, heat, vibrations or leaks from Generator?
-
Troubleshoot and organise for repair, add photos and notes if possible
-
Notes on issue
-
Photos
-
Any water leaks?
-
Troubleshoot and organise for repair
-
Does it look like there is sufficient discharge of water while pumps are operating?
-
Troubleshoot and organise for repair
-
Why is it not operating?
-
Enter the Reason
-
Do all Generator electrical leads look in good condition and have an in date electrical tag?
-
Alert supervisor and arrange for inspection and tagging immediately.
-
Is the fire extinguisher in date, pin in place and stored correctly?
-
Alert supervisor and arrange for replacement immediately
-
Is there a yellow spill kit bin in place, stocked and free of rubbish?
-
Cleanup any rubbish, notify your supervisor and arrange for restocking of spill kit
-
Is there rubbish around or is the work area untidy?
-
Remove of any rubbish from area and dispose of correctly.
Toe Well - Saddle Dam 5
-
Should the Toe Well be operating?
-
Record Water Level (m)
-
Record Totaliser Reading (m3)
-
Enter the Time of Totaliser Reading
-
Any water leaks?
-
Troubleshoot and organise for repair
-
Any unusual noises, heat, vibrations or leaks from Generator?
-
Troubleshoot and organise for repair, add photos and notes if possible
-
Notes on issue
-
Photos
-
Does it look like there is sufficient discharge of water while pumps are operating?
-
Troubleshoot and organise for repair
-
Why is it not operating?
-
Enter the Reason
-
Do all Generator electrical leads look in good condition and have an in date electrical tag?
-
Alert supervisor and arrange for inspection and tagging immediately.
-
Is the fire extinguisher in date, pin in place and stored correctly?
-
Alert supervisor and arrange for replacement immediately
-
Is there a yellow spill kit bin in place, stocked and free of rubbish?
-
Cleanup any rubbish, notify your supervisor and arrange for restocking of spill kit
-
Is there rubbish around or is the work area untidy?
-
Remove of any rubbish from area and dispose of correctly.
Toe Well - Saddle Dam 7
-
Should the Toe Well be operating?
-
Record Water Level (m)
-
Record Totaliser Reading (m3)
-
Enter the Time of Totaliser Reading
-
Any air or water leaks?
-
Troubleshoot and organise for repair
-
Does it look like there is sufficient discharge of water while pumps are operating?
-
Troubleshoot and organise for repair
-
Why is it not operating?
-
Enter the Reason
-
Is there rubbish around or is the work area untidy?
-
Remove of any rubbish from area and dispose of correctly.
Toe Well - Saddle Dam 8
-
Should the Toe Well be operating?
-
Record Water Level (m)
-
Record Totaliser Reading (m3)
-
Enter the Time of Totaliser Reading
-
Any water leaks?
-
Troubleshoot and organise for repair
-
Any unusual noises, heat, vibrations or leaks from Generator?
-
Troubleshoot and organise for repair, add photos and notes if possible
-
Notes on issue
-
Photos
-
Does it look like there is sufficient discharge of water while pumps are operating?
-
Troubleshoot and organise for repair
-
Why is it not operating?
-
Enter the Reason
-
Do all Generator electrical leads look in good condition and have an in date electrical tag?
-
Alert supervisor and arrange for inspection and tagging immediately.
-
Is the fire extinguisher in date, pin in place and stored correctly?
-
Alert supervisor and arrange for replacement immediately
-
Is there a yellow spill kit bin in place, stocked and free of rubbish?
-
Cleanup any rubbish, notify your supervisor and arrange for restocking of spill kit
-
Is there rubbish around or is the work area untidy?
-
Remove of any rubbish from area and dispose of correctly.
Toe Well - Saddle Dam 9
-
Should the Toe Well be operating?
-
Record Water Level (m)
-
Record Totaliser Reading (m3)
-
Enter the Time of Totaliser Reading
-
Any water leaks?
-
Troubleshoot and organise for repair
-
Any unusual noises, heat, vibrations or leaks from Generator?
-
Troubleshoot and organise for repair, add photos and notes if possible
-
Notes on issue
-
Photos
-
Does it look like there is sufficient discharge of water while pumps are operating?
-
Troubleshoot and organise for repair
-
Why is it not operating?
-
Enter the Reason
-
Do all Generator electrical leads look in good condition and have an in date electrical tag?
-
Alert supervisor and arrange for inspection and tagging immediately.
-
Is the fire extinguisher in date, pin in place and stored correctly?
-
Alert supervisor and arrange for replacement immediately
-
Is there a yellow spill kit bin in place, stocked and free of rubbish?
-
Cleanup any rubbish, notify your supervisor and arrange for restocking of spill kit
-
Is there rubbish around or is the work area untidy?
-
Remove of any rubbish from area and dispose of correctly.
Toe Well - Saddle Dam 9E
-
Should the Toe Well be operating?
-
Record Water Level (m)
-
Record Totaliser Reading (m3)
-
Enter the Time of Totaliser Reading
-
Any water leaks?
-
Troubleshoot and organise for repair
-
Any unusual noises, heat, vibrations or leaks from Generator?
-
Troubleshoot and organise for repair, add photos and notes if possible
-
Notes on issue
-
Photos
-
Does it look like there is sufficient discharge of water while pumps are operating?
-
Troubleshoot and organise for repair
-
Why is it not operating?
-
Enter the Reason
-
Do all Generator electrical leads look in good condition and have an in date electrical tag?
-
Alert supervisor and arrange for inspection and tagging immediately.
-
Is the fire extinguisher in date, pin in place and stored correctly?
-
Alert supervisor and arrange for replacement immediately
-
Is there a yellow spill kit bin in place, stocked and free of rubbish?
-
Cleanup any rubbish, notify your supervisor and arrange for restocking of spill kit
-
Is there rubbish around or is the work area untidy?
-
Remove of any rubbish from area and dispose of correctly.
Toe Well - Saddle Dam 10E
-
Record Water Level (m)
-
Record Totaliser reading m3
-
Should the Toe Well be operating?
-
Any water leaks?
-
Troubleshoot and organise for repair
-
Any unusual noises, heat, vibrations or leaks from Generator?
-
Troubleshoot and organise for repair, add photos and notes if possible
-
Notes on issue
-
Photos
-
Does it look like there is sufficient discharge of water while pumps are operating?
-
Troubleshoot and organise for repair
-
Why is it not operating?
-
Enter the Reason
-
Do all Generator electrical leads look in good condition and have an in date electrical tag?
-
Alert supervisor and arrange for inspection and tagging immediately.
-
Is the fire extinguisher in date, pin in place and stored correctly?
-
Alert supervisor and arrange for replacement immediately
-
Is there a yellow spill kit bin in place, stocked and free of rubbish?
-
Cleanup any rubbish, notify your supervisor and arrange for restocking of spill kit
-
Is there rubbish around or is the work area untidy?
-
Remove of any rubbish from area and dispose of correctly.
Toe Well - Saddle Dam 10W
-
Record Water Level (m)
-
Record Totaliser reading m3
-
Should the Toe Well be operating?
-
Any unusual noises, heat, vibrations or leaks from Generator?
-
Troubleshoot and organise for repair, add photos and notes if possible
-
Notes on issue
-
Photos
-
Any water leaks?
-
Troubleshoot and organise for repair
-
Does it look like there is sufficient discharge of water while pumps are operating?
-
Troubleshoot and organise for repair
-
Why is it not operating?
-
Enter the Reason
-
Do all Generator electrical leads look in good condition and have an in date electrical tag?
-
Alert supervisor and arrange for inspection and tagging immediately.
-
Is the fire extinguisher in date, pin in place and stored correctly?
-
Alert supervisor and arrange for replacement immediately
-
Is there a yellow spill kit bin in place, stocked and free of rubbish?
-
Cleanup any rubbish, notify your supervisor and arrange for restocking of spill kit
-
Is there rubbish around or is the work area untidy?
-
Remove of any rubbish from area and dispose of correctly.
Perimeter Sump 3B
-
Should the Perimeter Sump be operating?
-
Record Totaliser Reading (m3)
-
Enter the Time of Totaliser Reading
-
Any leaks?
-
Troubleshoot and organise for repair
-
Any unusual noises, heat or vibration from diesel pump?
-
Troubleshoot and organise for repair, add photos and notes if possible
-
Notes on issue
-
Photos
-
Why is it not operating?
-
Enter the Reason
-
Is the fire extinguisher in date, pin in place and stored correctly?
-
Alert supervisor and arrange for replacement immediately
-
Is there rubbish around or is the work area untidy?
-
Remove of any rubbish from area and dispose of correctly.
-
Is there a yellow spill kit bin in place, stocked and free of rubbish?
-
Cleanup any rubbish, notify your supervisor and arrange for restocking of spill kit
-
Is a life ring in place, stored off the ground and with a retrieval rope in good condition?
-
Alert supervisor and arrange for replacement immediately
Perimeter Sump 4
-
Should the Perimeter Sump be operating?
-
Record Totaliser Reading (m3)
-
Enter the Time of Totaliser Reading
-
Any leaks?
-
Troubleshoot and organise for repair
-
Any unusual noises, heat or vibration from diesel pump?
-
Troubleshoot and organise for repair, add photos and notes if possible
-
Notes on issue
-
Photos
-
Why is it not operating?
-
Enter the Reason
-
Is the fire extinguisher in date, pin in place and stored correctly?
-
Alert supervisor and arrange for replacement immediately
-
Is a life ring in place, stored off the ground and with a retrieval rope in good condition?
-
Alert supervisor and arrange for replacement immediately
-
Is there a yellow spill kit bin in place, stocked and free of rubbish?
-
Cleanup any rubbish, notify your supervisor and arrange for restocking of spill kit
-
Is there rubbish around or is the work area untidy?
-
Remove of any rubbish from area and dispose of correctly.
Perimeter Sump 5A
-
Should the Perimeter Sump be operating?
-
Record Totaliser Reading (m3)
-
Enter the Time of Totaliser Reading
-
Any leaks?
-
Troubleshoot and organise for repair
-
Any unusual noises, heat or vibration from diesel pump?
-
Troubleshoot and organise for repair, add photos and notes if possible
-
Notes on issue
-
Photos
-
Why is it not operating?
-
Enter the Reason
-
Is the fire extinguisher in date, pin in place and stored correctly?
-
Alert supervisor and arrange for replacement immediately
-
Is a life ring in place, stored off the ground and with a retrieval rope in good condition?
-
Alert supervisor and arrange for replacement immediately
-
Is there a yellow spill kit bin in place, stocked and free of rubbish?
-
Cleanup any rubbish, notify your supervisor and arrange for restocking of spill kit
-
Is there rubbish around or is the work area untidy?
-
Remove of any rubbish from area and dispose of correctly.
Perimeter Sump SD7A
-
Should the Perimeter Sump be operating?
-
Record Totaliser Reading (m3)
-
Enter the Time of Totaliser Reading
-
Any leaks?
-
Troubleshoot and organise for repair
-
Any unusual noises, heat or vibration from diesel pump?
-
Troubleshoot and organise for repair, add photos and notes if possible
-
Notes on issue
-
Photos
-
Why is it not operating?
-
Enter the Reason
-
Is the fire extinguisher in date, pin in place and stored correctly?
-
Alert supervisor and arrange for replacement immediately
-
Is a life ring in place, stored off the ground and with a retrieval rope in good condition?
-
Alert supervisor and arrange for replacement immediately
-
Is there a yellow spill kit bin in place, stocked and free of rubbish?
-
Cleanup any rubbish, notify your supervisor and arrange for restocking of spill kit
-
Is there rubbish around or is the work area untidy?
-
Remove of any rubbish from area and dispose of correctly.
Perimeter Sump SD7B
-
Should the Perimeter Sump be operating?
-
Record Totaliser Reading (m3)
-
Enter the Time of Totaliser Reading
-
Any leaks?
-
Troubleshoot and organise for repair
-
Any unusual noises, heat or vibration from diesel pump?
-
Troubleshoot and organise for repair, add photos and notes if possible
-
Notes on issue
-
Photos
-
Why is it not operating?
-
Enter the Reason
-
Is the fire extinguisher in date, pin in place and stored correctly?
-
Alert supervisor and arrange for replacement immediately
-
Is a life ring in place, stored off the ground and with a retrieval rope in good condition?
-
Alert supervisor and arrange for replacement immediately
-
Is there a yellow spill kit bin in place, stocked and free of rubbish?
-
Cleanup any rubbish, notify your supervisor and arrange for restocking of spill kit
-
Is there rubbish around or is the work area untidy?
-
Remove of any rubbish from area and dispose of correctly.
Perimeter Sump SD8A
-
Should the Perimeter Sump be operating?
-
Record Totaliser Reading (m3)
-
Enter the Time of Totaliser Reading
-
Any leaks?
-
Troubleshoot and organise for repair
-
Any unusual noises, heat or vibration from diesel pump?
-
Troubleshoot and organise for repair, add photos and notes if possible
-
Notes on issue
-
Photos
-
Why is it not operating?
-
Enter the Reason
-
Is the fire extinguisher in date, pin in place and stored correctly?
-
Alert supervisor and arrange for replacement immediately
-
Is a life ring in place, stored off the ground and with a retrieval rope in good condition?
-
Alert supervisor and arrange for replacement immediately
-
Is there a yellow spill kit bin in place, stocked and free of rubbish?
-
Cleanup any rubbish, notify your supervisor and arrange for restocking of spill kit
-
Is there rubbish around or is the work area untidy?
-
Remove of any rubbish from area and dispose of correctly.
Perimeter Sump 8B
-
Should the Perimeter Sump be operating?
-
Record Totaliser Reading (m3)
-
Enter the Time of Totaliser Reading
-
Any leaks?
-
Troubleshoot and organise for repair
-
Any unusual noises, heat or vibration from diesel pump?
-
Troubleshoot and organise for repair, add photos and notes if possible
-
Notes on issue
-
Photos
-
Why is it not operating?
-
Enter the Reason
-
Is the fire extinguisher in date, pin in place and stored correctly?
-
Alert supervisor and arrange for replacement immediately
-
Is a life ring in place, stored off the ground and with a retrieval rope in good condition?
-
Alert supervisor and arrange for replacement immediately
-
Is there a yellow spill kit bin in place, stocked and free of rubbish?
-
Cleanup any rubbish, notify your supervisor and arrange for restocking of spill kit
-
Is there rubbish around or is the work area untidy?
-
Remove of any rubbish from area and dispose of correctly.
Perimeter Sump SD9
-
Should the Perimeter Sump be operating?
-
Record Totaliser Reading that goes to F1 (m3)
-
Record Totaliser Reading that goes to R4 (m3)
-
Enter the Time of Totaliser Readings
-
Any leaks?
-
Troubleshoot and organise for repair
-
Any unusual noises, heat or vibration from diesel pump?
-
Troubleshoot and organise for repair, add photos and notes if possible
-
Notes on issue
-
Photos
-
Why is it not operating?
-
Enter the Reason
-
Is the fire extinguisher in date, pin in place and stored correctly?
-
Alert supervisor and arrange for replacement immediately
-
Is a life ring in place, stored off the ground and with a retrieval rope in good condition?
-
Alert supervisor and arrange for replacement immediately
-
Is there a yellow spill kit bin in place, stocked and free of rubbish?
-
Cleanup any rubbish, notify your supervisor and arrange for restocking of spill kit
-
Is there rubbish around or is the work area untidy?
-
Remove of any rubbish from area and dispose of correctly.
Perimeter Sump Condition
Sump Condition
-
Is there any wildlife in distress in any of the sumps?
-
Which Sumps have distressed wildlife?
- Perimeter Sump 3A
- Perimeter Sump 3B
- Perimeter Sump 4
- Perimeter Sump 5A
- Perimeter Sump 5B
- Perimeter Sump 7
- Perimeter Sump 8A
- Perimeter Sump 8B
- Perimeter Sump 9
-
Reported to the appropriate people
-
Is a life ring in place at each of the sumps, stored off the ground and with a retrieval rope in good condition?
-
Alert supervisor and arrange for replacement immediately
Beach Drains
-
Beach Drains in Operation
- SD 3
- SD 4
- SD 5
- SD 7
- SD 8
- SD 9
-
Are there any leaks from the pipework?
-
Record information on leak
Location
-
Select the location
- SD 3
- SD 4
- SD 5
- SD 7
- SD 8
- SD 9
-
Notes on the leak
-
Photos
-
Arrangements made for rectification
-
Totaliser Reading
Was the Inspection Completed?
-
Was the Inspection able to be completed?
-
Please Select a Reason
-
Comment on why inspection was not completed