Information

  • Re-Power Generator Refurbishment

  • Client NextEra Energy

  • Conducted on

  • Site Callahan Divide
  • Prepared by

  • Personnel

Generator Information

  • Generator Type

  • Serial

  • Pad #

  • Nameplate Photo

Disassembly Information

Repair Information/Tolerances DE and NDE Bearing Journal VEM 159 (+0.040/-0.015) Hitachi 149 (+0.040/-0.015) DE and NDE Bearing Housing VEM 340 (+0.036/-0) Hitachi 320 (+0.036/-0) DE Coupling Shaft Area 120mm (+0/-0.022) Collector Ring Total Indicated Runout (TIR) +/- 5mils Collector Ring Groove Depth Phase <1.00mm Ground <2.00mm

  • Generator Interior/Exterior

  • Noted Anomalies of Interior/Exterior

  • Brush Box Condition

  • Collector Ring Condition

  • Collector Ring Insulation Resistance Measurements Phase to Ground

  • Collector Ring Runout Pass/Fail Record numbers if failed

  • Collector Ring Groove Depth Pass/Fail Record numbers if failed

  • NDE Condition

  • NDE Bearing Journal Pass/Fail Record numbers if failed

  • NDE Bearing Housing Pass/Fail Record numbers if failed

  • NDE Additional Findings

  • DE Condition

  • Coupler Shaft Diameter Pass/Fail Record numbers if failed

  • DE Bearing Journal Pass/Fail Record numbers if failed

  • Bearing Housing Pass/Fail Record numbers if failed

  • DE Additional Findings

  • Interior of Rotor and Stator Boxes

Assembly Information

  • NDE Bearing Greased and Installed

  • NDE End bell Installed

  • Brush Box Cleaned and Installed

  • Collector Ring Installed

  • Cleaned Collector Ring Insulation Resistance Readings/Phase to Ground

  • DE Bearing Greased and Installed

  • DE End Bell Installed

  • GEN Coupler Installed

  • Completed Unit

  • Upper Fan (If Applicable) Motor Function Test Results Pass/Fail

  • Heat Exchanger Fan Motor Function

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.