Title Page

  • Post

  • Property

  • Conducted on

  • Prepared by

FUEL BURNING APPLIANCES AND EQUIPMENT - Furnaces, Boilers, Water Heaters, Kerosene Heaters, Space Heaters, Dryers, Fireplaces

Venting of Exhaust Gases

  • Outdoors away from intakes and windows

  • Traducción al español

  • Chimney and flue constructed and installed properly (per manufacturer))

  • Traducción al español

  • Chimney and flue inspected annually and cleaned

  • Traducción al español

Combustion Air

  • Adequate combustion air ducted to unit or

  • Unobstructed area large enough to provide adequate combustion air

  • Small mechanical areas have sufficient combustion air and ventilation openings

  • No hazardous or flammable vapor sources near combustion equipment

  • Traducción al español

Operation and Maintenance

  • Instructions available for proper operation and maintenance

  • Traducción al español

  • Equipment operated and maintained as intended within design limits

  • Traducción al español

  • Warning labels (English and local language) present on combustion appliances

  • Traducción al español

Clearance to Combustibles

  • Clearance at least 1 m (3 ft) from exhaust flue to combustible materials

  • Clearance at least 1 m (3 ft) from equipment to combustible materials

  • Boiler and furnace rooms not used for storage areas

  • Traducción al español

Fuel Type and Storage

  • Fuel used is appropriate for appliance(s)<br>

  • Proper type and location of fuel storage container (including tanks)

  • Protect fuel storage containers from damage and secure them for protection against weapons of opportunity

  • Traducción al español

Carbon Monoxide Alarms

  • Carbon monoxide alarm installed, at about eye level, outside of sleeping areas (including household staff) in residences with any combustion appliance (other than cooking oven/stove) or an attached garage

  • Traducción al español

Generators

  • Generator

  • Enclosed in sound attenuated and weatherproof housing

  • Adequate space and, if leased, landlord agrees to the generator placed outdoors as far away as practical and a minimum of 1.5 meters (5 feet) from any building

  • Exhaust outlets >= 3 feet (1 meter) from exterior wall and roofs, 10 feet (3 meter) from operable opening into buildings, and 10 feet (3 meter) above adjoining grade

  • If distance and direction of exhaust is not feasible, then extend 3 ft. above the building. (See "Venting of Exhaust Gases" section)

  • Traducción al español

Portable kerosene heaters

  • Portable kerosene heaters

  • Single family home use only

  • Correct grade of kerosene (K-1) fuel stored outside in safety cans

  • Refuel outdoors away from sources of ignition, and after the heater has cooled completely

  • Set the wick height to the manufacturer's recommended level

  • Chimney is seated properly

  • Window opened slightly (e.g., 25mm/1 inch) in the room with the heater

  • Do not leave the heater unattended and turn off before going to bed

  • Keep the heater at least 1m (3 ft.) from combustibles unit is operated and maintained according to the manufacturer's instruction and residents are informed of the instructions

  • Carbon monoxide alarms must be placed in dwelling

  • Traducción al español

LIQUEFIED PETROLEUM (PROPANE) GASES (LPG)

Cylinders during use:

  • - must be located on the exterior of the building

  • - equipped with a pressure regulator having a pressure relief valve

  • - upright and securely anchor or chained in place

  • - at least 7.6 m (25 ft.) from sources of ignition and 1.5 m (5 ft.) from building openings

  • Traducción al español

Cylinder storage

  • - outside within a fenced enclosure

  • - outlet valves close with cap or cover

  • - steel posts or barriers if vehicle damage is possible

  • - "No Smoking" signs clearly displayed around the storage enclosure with universal symbols or local language and English

  • - Secure tanks to ensure they cannot be used as weapons of opportunity

  • Refilled tanks or bottles delivered, no recharging or filling of tanks or bottles at the site

  • Trained employees for LPG installation and cylinder replacement

  • Post Facility Managers or Post Occupational Safety and Health Officers (POSHO) must coordinate inspections of residences/apartment buildings, which have natural gas and ensure the local gas authority has certified lines and valves

  • Traducción al español

All Gas Service

  • Supply through rigid pipe (iron or steel), or tubing (steel, brass or copper)

  • - exceptions for seismically active areas-see Seismic Safety

  • Interior manual shut‐off valve accessible and within 1.8 meters (6 ft) of appliance

  • Secured to ensure safe against weapons of opportunity

  • Leak detection using soapy water or other means must be conducted over all fittings and connections during cylinder or appliance replacement or anytime supply line work is done

  • Post Facility Managers or Post Occupational Safety and Health Officers (POSHO) must coordinate inspections of residences/apartment buildings, which have natural gas and ensure the local gas authority has certified lines and valves

  • Traducción al español

FIRE AND LIFE SAFETY

Emergency egress

  • Adequate emergency egress can vary with the type of building. Consult the Fire Protection Guide (FPG) for guidance

  • Traducción al español

Maximum Travel Distance to an Exit

  • Without automatic sprinkler protection: 30 meters (100 ft)

  • With complete fire detection system and sprinkler protection in selected areas: 46 meters (150 ft)

  • With complete fire sprinkler system: 61 meters (200 ft)

  • Traducción al español

High Rise Matrix

  • Is this an apartment building?

  • Stairs: 2 Exit Stairs Fire Alarm/Detection System: Full Fire Sprinkler System: Full # of Apartments Per Floor: --- Real Estate Decision: Lease on any floor Stairs: 2 Exit Stairs Fire Alarm/Detection System: Full Fire Sprinkler System: None # of Apartments Per Floor: --- Real Estate Decision: Lease at or below 5th floor Stairs: 1 Exit Stair Fire Alarm/Detection System: Full Fire Sprinkler System: Full # of Apartments Per Floor: Only 2 per floor Real Estate Decision: Lease at or below 6th floor Stairs: 1 Exit Stair Fire Alarm/Detection System: Full Fire Sprinkler System: Full # of Apartments Per Floor: More than 2 per floor Real Estate Decision: Lease at or below 4th floor Stairs: 1 Exit Stair Fire Alarm/Detection System: Full Fire Sprinkler System: None # of Apartments Per Floor: --- Real Estate Decision: Lease at or below 3rd floor Stairs: 1 Exit Stair Fire Alarm/Detection System: None Fire Sprinkler System: None # of Apartments Per Floor: --- Real Estate Decision: Do not lease

  • Traducción al español

Smoke Alarms (updated 2013)

  • Each sleeping room

  • Outside of each separate sleeping area, in the immediate vicinity of the sleeping rooms

  • On each level of the dwelling unit, including basements

  • Placement should be on the ceiling, or alternately on a wall between 4" (10 cm) to 12" (30.5 cm) away from the ceiling

  • Occupants instructed to check detectors monthly for proper operation

  • Traducción al español

Portable Fire Extinguishers

  • One department standard 10 lb. (4.45 kg) extinguisher (4-A:40-B:C)

  • Wall mounted in or near each kitchen

  • Traducción al español

Alarm Systems

  • Does the property have an alarm system?

  • Several factors influence automatic fire alarm detection and/or automatic suppression system requirements

  • Consult the Fire Protection Guide (FPG) and contact OBO/OPS/FIR

  • Traducción al español

Lighting

  • Is this an apartment building?

  • Apartment buildings or congregate residences with 10 or more occupants: public space, hallway, stairway or other means of egress must have illumination of 1 foot candle power at floor level by emergency lighting

  • If emergency generator is not available to provide emergency lighting, provide battery‐powered emergency lights in public <br>spaces, hallway, stair way or other means of egress installed and maintained correctly

  • All emergency light fixtures shall have 90 minutes battery backup regardless of generator power availability.

  • Traducción al español

Exit Signs

  • Is this an apartment building? Then Exit doors in public corridors on floors with sleeping accommodations:

  • - Illuminated exit signs

  • - Directional signs if path is not straight or the exit is less than obvious

  • Traducción al español

Window Grilles

  • Are grilles installed?

  • Operable from the inside

  • Minimum opening: 5.7 ft. squared (0.529 meters squared)<br>

  • Minimum dimension: 24" (61 cm) x 20" (51 cm) and not be more than 44" (112 cm) from the floor

  • Bars or grilles must have inside release mechanism

  • Traducción al español

WATER HEATER PROTECTION (Temperature and Pressure Relief Valves )

  • Separate temperature and pressure relief valves (PRV and TRV) or combination temperature and pressure relief valves (TPRV) installed

  • TPRV drain piping installed to direct discharge floor

  • TPRV drain piping is not reduced, threaded at the end and has no uphill runs

  • TPRV drain piping has no other valve downstream of TPRV

  • Water temperature is not above 120 degrees F (49 degrees C)

  • Traducción al español

PLATE GLASS SAFETY (Tempered/Safety Glass Locations )

  • Locations listed below need to ensure that glass is tempered, mylar coated, a non‐breakable replacement material or protected by a barrier. Decals or markings should be used where the presence of glass is not easily seen.

  • Entry and exit doors, storm doors, glass sliding doors

  • Windows located within 18" (46 cm) of the floor

  • Doors and enclosures for bathtubs, showers, sauna

  • Stairway enclosures and handrail panels

  • Traducción al español

GARAGE DOOR SAFETY

  • Safety Features: <br> Inherent reversal system. This system can be a photo eye, a door edge sensor, or any other device that provides equivalent protection. If an electric eye is used, it should be installed at a height of 4 to 6 inches above the floor

  • Design: - - - 1. Door is properly balanced. A properly balanced garage door will stay in place when stopped in any partially open position.<br>2. Install the push button wall control as high as practical on the garage door’s wall to restrict children's access to it. Ensure remotes are out of reach of children and that children are educated about the potential dangers with these mechanisms and the garage doors they operate.

  • Maintenance: Ensure garage doors are inspected annually and preventative maintenance is conducted routinely. <br>a. Manually check door springs, hinges, cables, rollers and/or bearings, and ensure that reversal system sensors are clear and free of obstruction. <br>b. Check door insulation for pest harborage and ensure insulation is intact. <br>c. Door should go up and down easily when operated manually. <br>d. Door opener should be attached with a reinforcement bracket.

  • Traducción al español

ELECTRICAL

Ground Fault Circuit Interrupters

  • Installed for wet locations (indoors and outdoors) and all kitchen countertop outlets at the outlet or the circuit breaker:

  • - 110-volt systems, installed GFCIs trip at 4 to 6 mA

  • - 220-volt systems, installed GFCIs trip at 10 mA

  • Do not install outlets where local code prohibits them in certain wet locations

  • Traducción al español

Appliance Cords

  • In good condition, insulated, and provided with a plug.

  • Traducción al español

Grounding

  • A grounding electrode connected to panel at the service entrance and bonded to the neutral (grounded) conductor. Impedance of the ground path for any made electrodes may not exceed 25 ohms, as measured using appropriate stake or stakeless ground resistance testing equipment. Verify and, if missing, contact the FIR/FAC Help Desk via e‐mail (obo@cesengineers.com) or call 866949‐6751 for assistance with grounding system installation

  • Grounding Ohms value

  • Traducción al español

Electric Service Supply & Panels

  • Missing knock-outs and twist-outs in beaker/fuse panel(s) must have fill plates

  • Traducción al español

  • Breaker/fuse panel front working clearance of 30" (76 cm) wide x 36" (92 cm) deep

  • Traducción al español

  • Breaker and fuses labeled as to function/area served

  • Traducción al español

  • Outdoor outlets are GFCI and have weatherproof boxes

  • Traducción al español

Circuit Capacity

  • Review usage and capacity and avoid excessive electrical loads. Verify that the following most commonly used branch circuit connectors in residences are protected by fuses or circuit breakers having trip elements not larger than:<br><br>Wires (Comparable U.S. Wire Size): Trip Setting:<br>1.5 mm squared (smaller than #14 AWG, 15A) 10A<br>2.5 mm squared (smaller than #12 AWG, 20A) 16A<br>4 mm squared (smaller than #10 AWG, 30A) 25A<br>6 mm squared (smaller than #8 AWG, 50A) 40A<br>10 mm squared (smaller than #6 AWG, 65A) 50A<br>16 mm squared (smaller than #4 AWG, 85A). 60A

  • Traducción al español

FALL PROTECTION

Railings

  • Are railings existing or required to be installed?

  • Installed on all railings porches, balconies and raised floor surfaces more than 30" (76 cm) above the floor or grade below <br>

  • Sturdy supports (balusters) with no openings larger than 4" (10 cm) and bottom of railing assembly no more than 4" (10 cm) from the floor and can withstand the force of 91 kilograms (200 lbs) in any direction

  • Guardrails at a minimum height of 91 centimeters (36 in) (107 cm/42 in is recommended) for balconies, decks, elevated patios, and other similar structures for single family and duplex housing units.

  • Guardrail installation at apartments and representational areas open to the public must be 107 centimeters (42 in) high

  • Traducción al español

Stairs and Handrails

  • Are the stairs and handrails?

  • For open stairways, supports (balusters) no more than 10 centimeters (4 in) apart. Triangle formed by riser, tread and <br>bottom guardrail element does not allow passage of sphere 152 millimeters (6 in) in diameter

  • Handrails installed for stairways at 86‐97 centimeters (34‐38 in)

  • Stair riser height maximum 196 millimeters (7.75 in), treads minimum depth 254 millimeters (10 in)

  • Stairways are not to be less than 91 centimeters (36 in) in clear width at all points above the handrail height

  • Spiral stairway treads must have a minimum tread width of 66 centimeters (26 in). Treads shall have a minimum tread depth of 190 millimeters (7.5 in) measured at a point 305 millimeters (12 in) from the side where the treads are narrower.

  • Handrails and the top rails of stair rail systems are capable of withstanding, without failure, a force of at least 91 kilograms (200 lbs) applied within 5 centimeters (2 in) of the top edge, in any downward or outward direction, at any point along the top edge

  • Traducción al español

Homes with Small Children

  • Latching device on windows allows opening no more than 4-5" (10-13 cm), but windows remains operable

  • Furniture away from windows and railings

  • Traducción al español

SWIMMING POOLS (Barrier and Safety Features)

  • Is there a swimming pool in the complex?

  • Barrier: A permanent, 4‐sided, non‐climbable barrier (fence, wall, etc.) ≥ 122 centimeters (4 ft) height that prevents direct access <br>from living areas and excludes ancillary activities (e.g., barbecues, bars, ping‐pong tables). <br>a. Self‐closing, self‐latching, lockable hardware on all access points (gates/doors) with latch release ≥ 137 centimeters (54 <br>in) . Alternatively, the latch release can be on the pool side of the gate if ≥ 7.6 centimeters (3 in) below the top with no <br>opening > 1.3 centimeters (0.5 in) within 4.5 centimeters (18 in) of the release. <br>b. Gates/doors must open away from the pool. <br>c. Barrier distance from pool must be between 1.5m and 5.2m (5 – 17 ft) to allow for emergency response and to exclude <br>ancillary activities.

  • Traducción al español

  • Other: <br>a. No entrapment hazards<br>b. Rescue equipment available (shepherd’s crook, pole, ring buoy) and in plain view<br>c. Depth markings and no diving indicated. Safety rules posted at community use pools and residential use pools that are used as community use pools, i.e., CMR, MSGR <br>d. First aid kits and emergency communication means for community use pools and residential use pools that are used as community use pools<br>e. Outlets equipped with Ground Fault Circuit Interrupters (GFCI) and covers<br>f. Pool chemicals stored separate from other materials in a cool, dry, ventilated area with restricted access <br>g. Drain covers are being replaced every 5 years

  • Traducción al español

ELEVATORS

  • Is there an elevator?

Elevator Lobby & Car

  • All elevator cars have functional doors independent of shaft doors

  • Elevator doors (car & shaft) reverse direction when an object is either contacted by the leading edge of the door or detected by an electronic door protection device

  • All external car operating features, lobby controls and hardware are intact and function properly

  • Car operating buttons, including the emergency alarm button, function properly

  • Car lights are on and bulbs or tubes are secure

  • Car service panel is locked

  • Car emergency phone is connected to a 24-hour operator

  • Car's audible signals are operating

  • All door mechanisms are enclosed to avoid pinch/shear points

  • Traducción al español

Machine Room & Maintenance

  • Machine room access door is locked and keys stored securely

  • Good housekeeping, no trash, not being used as a storage area, no excessive oil leaks, control cabinet(s) intact

  • Illumination is adequate to perform inspection

  • ABC fire extinguisher located in machine room

  • Temperature is not above 120 degrees F (49 degrees C)

  • Elevator is under a service contract and service logbook is utilized and up to date

  • Elevator has a current safety certificate

  • Traducción al español

ENVIRONMENTAL

Asbestos

Air pollution

  • At least 150 meters away from major roadway (recommended) <br>

  • No other nearby air pollution sources [e.g., drycleaner or large fueling station (14M l/year) within 100m]

  • Property barrier and vegetation (recommended)

  • Centralized air filtration (otherwise room air cleaners may be needed)

  • Traducción al español

  • Asbestos detected?

  • Acquisitions: asbestos inspection conducted and impact of asbestos determined

  • Asbestos materials identified and maintained in good condition

  • Maintenance and minor renovations avoid disturbance of asbestos materials

  • If asbestos material is to be disturbed, it is removed properly and records of removal and disposal are maintained

  • Traducción al español

Leaded Paint

  • Only lead‐free paint is applied (e.g., < 90 ppm in dried paint film)

  • Painted surfaces in good condition with minimal damage

  • Paint sampled prior to renovation or major maintenance work

  • Leaded paint removed prior to start of work or minimize disturbance

  • Traducción al español

Pesticides

  • Building conditions or location not inviting to common local pests

  • No history of chronic pest problems or extensive pesticide use

  • Willing and capable to implement Integrated Pest Management (IPM) program in USG occupied space

  • Habitats and attractants to common pests avoided

  • Self‐help measures, to include self-help education, are available to control pests (if control measures are not effective)

  • Professional pesticides, used outdoors only, are a last resort and limited to Department‐authorized products

  • Traducción al español

Drinking Water Quality

  • Tap water is potable (microbiologically safe and within acceptable contaminant levels listed in the Department's drinking water standards). If there are multiple zones, they are noted on the QC program

  • If tap water is not potable, then supplemental means (e.g., point of use device such as a distiller) are used to render the water potable and quality control monitoring is done

  • Water used for bathing water and other contact uses meets recreational water criteria

  • If supplemental treatment is employed, O&M and QC programs are in place

  • Unless a lead‐removing POU is employed, water from the main taps is confirmed by testing to have lead levels below 15 ppb

  • Traducción al español

SEISMIC ISSUES (FOR POSTS IN SEISMIC ZONES 2 OR HIGHER)

  • Seek seismically best available structures in accordance with expectations outlined in 19 STATE 74458 and in collaboration with <br>OBO's Climate Security & Resilience Program

  • Generators should be securely anchored (ground or slab) at all anchorage points of the frame, and generator connections should <br>be flexible (earthquake resistant).

  • Propane tanks, kerosene heaters: use flexible connections to the tank and anchor storage tanks to the ground, fence, or wall to <br>prevent tipping

  • Water heaters, propane (LPG) gas cylinders and natural gas: <br>a. Use flexible, metallic connections for water and gas lines <br>b. Use metal straps which are bolted using expansion bolts to a masonry/concrete wall, or lag bolts to a wood stud wall, at <br>the top and bottom of the water heater and propane cylinders <br>c. Block in space between water heater and wall to prevent rocking

  • Heavy and tall furniture such as bookcases should be secured to prevent sliding or tipping, using L‐brackets or other device and <br>remove casters or wheels to prevent rolling

  • Check for weaknesses in chimneys such as damage or missing bricks. If roof is not composed of concrete, verify that the max <br>height above the roof line is no more than 2 times the least side dimension (or chimney is braced)

  • Ensure cabinet latches are strong enough, especially in the kitchen, to prevent contents from falling out; install safety latches for <br>added security

  • Brace and bolt storage racks and shelves to the floor and walls and secure contents so they can’t slide off

  • Mini‐split HVAC Units: To prevent tipping, confirm secure anchorage/attachments to all anchorage points for the unit

  • Traducción al español

LOCAL CONSIDERATIONS

WINDOWS' CORDS Blinds, curtains and shades

  • Cords must be separated and independent avoiding a continuous rope

  • A lock or butterfly type lock attached to the Wall is used to tie the cords to let them out of children reach

  • Tensors fixed to the floor or wall to avoid cords or chains to form a continuous rope.

  • Traducción al español

ROOF ACCESS

  • Is there an adequate ladder to access the roof?

  • Access to roof is limited.

  • Traducción al español

WATER STORAGE TANKS Cistern

  • Is the cistern cover locked with a padlock? <br>

  • Has the cistern manhole a built in frame barrier?

  • Cistern washing has been documented or recently made?

  • Traducción al español

OTHER

  • Steam resistant lamps in all bathrooms shall be placed <br>

  • Traducción al español

  • Traducción al español

  • 30 A electrical outlet to electrical heaters per each bedroom.

  • Is there a bathtub?

  • Place a handle to the bathtub

  • Traducción al español

  • Is there a chimney?

  • Perform and document maintenance of the chimney as required

  • Traducción al español

  • Have all fall or health hazards been avoided as possible?

  • Traducción al español

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.