Title Page
-
Fleet No:
-
Site:
-
Auditor:
-
Audit Date:
-
Vehicle Cond.
-
Next Audit Due:
-
Engine Hours:
-
KM's:
GENERAL
-
General cabin appearance & cleanliness (inside & out) No rubbish in the cab and it is clean. No loose equipment in cab.
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Cab & Bodywork Being maintained in good condition, not corroded or damaged
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Chassis & Running Gear Being maintained, not corroded or damaged
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Storage boxes, cabinets & toolboxes Clean and functional
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Fire extinguisher Evident they are being maintained
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
In Cab Documentation Evident emergency procedure guides, safe handling guides, and licenses are being maintained. ie licence to manufacture, licence to operate and registration
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
NHVAS Stickers attached, Interception book present
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Safety Equipment Evident DG PPE Kit, First aid kit, Saline eyewash, Hazard triangles, wheet nut indicators and chocks
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Volvo basic toolkit In place
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Safety Signage All required safety signage is in place and being maintained in clear legible condition
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Guarding All guarding being maintained including is in place, is secure and has the correct legible signage
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Lubrication Evidence that all grease points are being maintained, autogreasers are being filled and remote grease lines are being maintained
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
System operation Are all guages, counters and RPM readouts operational and being maintained
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
IVMS
-
IVMS Last recordered entry in Masterblast to match Engine hrs on dashboard hr meter.
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
IVMS DVR unit Check IVMS DVR unit status indication lights. Check Amber "REC" light is ON, and Red "ALARM" light is IVMS DVR Unit NOT ON.
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
IVMS Dash Mount Screen Check unit is operational and user can be logged on
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
IVMS Dash Mount Screen Check unit is securely mounted, with no signs of Check cables and plugs are undamaged and securely attached
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
IVMS Cameras Check cameras are operational, securely mounted and aligned
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
CHASSIS & BIN
-
General appearance, cleanliness Evident that the unit is being maintained
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Fall protection Being maintained in good condition
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Top of MMU bins Being maintained in good condition. All items secure and in good condition
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Relief / roll over devices, visual check only Evident they are being maintained
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Bins No external leaks, cracks or damage
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Cleanliness & Crystalisation build ups MMU bins are clean, no leaks including around ANE pipe work & valves etc
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
AN SYSTEM
-
Auger bearing standoff gaps All bearing stand offs in place and clear
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Auger end seals, visual check Being maintained, are intact and not leaking
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
AN auger metering tube, visual check Is being maintained, is free from dents or cracks, no sign or corrosion, mounting bolts tight
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
AN auger straightness, alignment & flights, visual check BM7 Incline Auger Is being maintained, in good condition, no sign rubbing, extraordinary noise or vibration BM7 incline Auger. Ensure there is at least a 10mm gap between the bottom of the incline auger seal 1"slinger" and auger tube end plate.
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
DISCHARGE AUGER
-
DA slew motor and gearbox. Evidence of inspections being completed, clean and free from leaks or damage. Nothing cracked or loose
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Discharge auger assembly & cradle Is being maintained and kept clean. Is in good condition. No cracks, no sign of corrosion. Safety chains functional
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
DA lift lift system In being maintained in good condition. All lifitng components are correctly fitted and in good condition
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
CRITICAL PUMPS
-
Documentation Log book is present and up to date
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Thermofuses Is clear or obstruction, not leaking
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Lubrication & maintenance Are in good condition with evidence they are being properly maintained and lubricated
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
HOSE REELS
-
Hose reels, motors, hoses and fittings. Hose reel drive are being maintained in good condition. Hoses and fittings are being maintained including burst protection and denso tape applied
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Hose reel operation Working correctly, properly adjusted and maintained
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Hose reel drums, structures & guarding In good condition, not corroded, damaged, or loose
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Hose boom, cylinder, rotary unions, linkages, hoses & fittings In good maintained condition. Not damaged or degraded. Hoses and fittings are being maintained. iSafety chains functional
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
All flexible hoses including bull hoses and product delivery hoses Being maintained in good condition, no splits, leaks or dents, firmly attached with hose clamps no exposed wire or other damage
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
CHEMICAL ADDITIONS SYSTEM
-
CA pumps Are being properly maintained, are functioning correctly, in good condition, no degradation or leaks
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Pump cabinets Are being kept clean and maintained includings hatches seals etc
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
CA tanks Maintained, clean and in good condition including mounts, breathers, fitting and sight tubes
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
WATER SYSTEM
-
Water pump, motor, couplings, lines & fittings The system is being maintained, in good condition
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Water tank, mounts, breathers, fittings, and lines Maintained, in good condition, not leaking or degraded, sight glass, breathers and filters are being cleaned
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
FO SYSTEM
-
Process fuel pump hoses & fittings The system is being maintained including no leaks no degradation and denso tape is applied
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Process fuel tank & mounts Being Maintained. No signs of leaks. Secure with no damage
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
HYDRAULIC SYSTEM
-
Step up box No excessive noise, no leaks. Hydraulic reservoir system functioning, Mounting bolts secure
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Hydraulic pumpsets, hoses & fittings No oil leaks, no noises or signs of corrosion. Denso tape applied
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Hydraulic tank & Mounting Being Maintained. No signs of oil leaks. Oil Level visible in sightglass. Secure with no damage or corrosion
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Hydraulic manifolds, valves, fittings & hoses Being maintained, clean, no leaks and denso taped
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
All hydraulic manifold hoses & fittings No signs of leaks, no splits in hoses, no cracks or corrosion in fittings, Denso tape applied
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Hydraulic pipes & fittings Evident that system is being maintained including no leaks, denso tape is in place and hoses are in good condition
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Hydraulic motors, Couplings & components Are being maintained and are in good condition. Couplings intact
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
All hydraulic cabinets Clean, no signs of leaks, door and cover seals intact
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
All guages, indicators & controls In good working condition
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
PNEUMATICS
-
Air valves, water traps, lubricators The system is being maintained. Water traps are being emptied, no air leaks
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
ELECTRICAL SYSTEM
-
Battery Isolator & remote button Is being maintained and operates correctly
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Roll over sensor Is being maintained and operates correctly
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
E Stop system Is being maintained and operates correctly
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
All electrical & control panels Maintained in good, sealed, clean condition. All components are functional
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Electrical conduits & wiring All wiring well maintained in conduits, secure and undamaged. No unauthorised modifications
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Exernal Electical Components including flashing amber light, reverse beeper & work lights Maintained in good working condition
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Process control panel & cabinet Cabinet secure & clean, switches & pots operative and labelled, readouts legible, wiring secure. All in good condition
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
-
Batteries, Lids, Cables Batteries are being maintained. Clean, secure, guarded condition
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
ANFO BLOWER
-
Blower Assemblies, hoses, fittings etc Maintained in good working condition _
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
QUALITY CONTROL
-
Scales, Test Weights, Density Cups & Thermometer Are present, and being calibrated .
- 1 - Safety Critical
- 2 - Urgent
- 3 - High
- 4 - Medium
- S- Low
- No Action Required
MMU Configuration Management Checklist
-
Fleet No:
-
Plant:
-
Date:
-
Water Tank
-
Water Tank Capacity
-
Auger Guarding Upgraded
-
Fall Protection
-
Control System
-
Pump Protection
-
Hydraulic System Coiling Fan
-
Fail Safe E Stop Circuit
-
PLC Cabinet Su. sort Brackets
-
Battery Box Cover
-
Rollover Protection Switch
-
Battery Isolator
-
Variable Flight Auger
-
HEB / XP - Aluminium System
-
Type of 25mm NB Hose Reel
-
25mm NB Hose Reel
-
Powered 1.5 inch Hose Reel
-
Bin Lids
-
Blower System
-
Auger Interface
Sign-off
-
Prepared by
-
Date