Information

  • WELL NUMBER

  • Robinson Drilling Rig Inspection

  • RIG #.

  • Conducted on

  • Prepared by

  • Location

DRILL SITE LOCATION

  • Authorized Personnel Sign Posted at entrance to site<br>1910.145(c)(2)(i)<br>RP54 7.1.2-3<br>Hard Hat/Safety Glasses/Steel Toe Shoe Signs Posted at prominent locations on site<br>191t0.145(c)(3)<br>No Smoking Area’s Designated & Posted. RP54 7.1.2-3. 1910.145(c)(2)(i)<br>

  • Visible rig identification sign erected at entrance to site road and at all directional changes on site road (for 911 services) <br> 1910.151(a) <br>

  • H2S/SO2 warning signs erected, if applicable, at entrance to site and at other prominent locations on site <br> <br>1910.145(c)(2)(i) <br>1910.1000(e) <br>1910.1200(f)(5-6) <br>RP54 7.1.2-3 <br>RP49 5.1 <br>RP68 6.9 <br>

  • Escape line flagged with visible material <br>RP4G 14.5.f <br>

  • Outhouse/restroom facility provided or in close proximity to the site. (LT 10 min travel time or 2 miles, whichever is less) (Facility in close proximity only applies if the site is active for less than 1 day) <br>1910.141(c)(1)(i) <br>

  • Outhouse clean and sanitary, if provided. <br>1910.142(d)(10) <br>

  • Toolpusher’s trailer grounded <br>RP54 6.1.16 <br>

  • Housekeeping <br> 1910.22(a)(1) <br>RP54 6.5.1 <br>

  • Muster area designated. 1910.38(c)(4)<br>1910.145(c)(3)

  • Warning signs clean and visible <br>1910.1200(f)(9) <br>

  • Supply storage house clean <br>1910.22(a)(1) <br>RP54 6.5.1 <br>

  • Wind Sock available. <br>RP49 8.2.3 <br>RP68 6.8, 8.2.4 <br>

  • General :

PPE & GENERAL SAFETY

  • Pre-Job safety meeting held. RP54 6.1.7 <br>

  • Proper clothing worn by crew (No loose clothing). <br> RP54 5.2.5 <br>RP54 5.2.6 <br>1910.132(a) <br>

  • Hard hats used by crew <br>RP54 5.2.1 <br>1910.135(a)(1-2) <br>

  • Safety glasses used by crew <br>RP54 5.2.2 <br>1910.133(a)(1-5) <br>

  • Steel toed shoes used by crew <br>RP54 5.2.3 <br>1910.136(a) <br>

  • Hazardous jewelry not worn by crew <br>RP54 5.2.7 <br>

  • No Smoking rules observed <br> RP54 7.1.3 <br>

  • General :

​MUD PUMP AREA

  • Drive belts and shafts guarded and Rotating parts guarded<br> 1910.212(a)<br>1910.219(i)(2)<br>RP54 6.8.2-3<br>1910.219(e)(1-6)<br>1910.219(c)(2)(i)<br>

  • Pony rods guarded <br>RP54 6.8.2-3 <br>1910.212(a) <br>

  • Head and valve covers fully bolted <br> <br> <br> <br>

  • Shear pin pop-off valve present and covered <br>1910.169(b)(3)(i-iv) RP54 9.13.11 <br>

  • Ends of mud vibrator hose snubbed <br> <br>

  • Pressure relief valves properly set<br>1910.169(b)(3)(i-iv)<br>RP54 9.13.2<br>

  • Discharge lines from relief valves are anchored RP 54 9.13.2 <br>

  • Ends of relief lines, high pressure lines, etc secured <br>RP54 9.13.3 <br>

  • Warning signs clean and visible <br>1910.1200(f)(9) <br>

  • General housekeeping of the area. RP54 6.5.1, 1910.22(a)(1)<br>

  • Adequate lighting provided <br>RP54 9.14.7 <br>

  • Approved lighting for the location available <br>1910.307(b)(1) RP500 5.3 RP500 10.1-16 <br>

  • Pumps, piping, hoses, valves and other fittings are maintained in good operating condition. RP54 9.13.4 <br>

  • General :

MUD MIXING AREA

  • Bagged material properly stacked. 1910.176(b) <br>

  • Adequate personal protective equipment available: □ Rubber Gloves □ Apron □ Face Shield □ Goggles <br>□ Respirator: □ Other:________. RP54 5.2.4. RP54 6.13.2. 1910.132(a). 1910.133(a). 1910.134(a)(2). 1910.138(a)(1) <br> <br> <br> <br>

  • Personal protective equipment properly stored and protective equipment properly maintained and in a clean & sanitary condition. RP54 6.13.2 1910.132(a) 1910.134(h)(1)<br>. RP54 6.13.2. 1910.132(a). 1910.134(h)(2)(i)<br>

  • “PPE Required” warning signs erected (Grouped or individual signs)<br> 1910.145(c)(3)<br>

  • Warning signs clean and visible <br>1910.1200(f)(9) <br>

  • Eye wash/shower station available in close proximate area to hazard 1910.151(c) Z358.1 5.4.2 RP54 4.4.1<br>

  • Eye wash/emergency shower access free from obstructions. Z358.1 5.4.2 <br>

  • Eye wash station/emergency shower in working order 1910.151(c) <br>

  • Eye wash station/emergency shower providing clean water supply. 1910.141(b)(1)(i) 1910.141(a)(3)(hi)<br>

  • Approved lighting for the location available. 1910.307(b)(1) RP500 5.3. RP500 10.1-16 <br>

  • Adequate lighting provided. RP54 9.14.7 <br>

  • General housekeeping RP54 6.5.1. 1910.22(a)(1) <br>

  • General :

MUD TANKS AND PITS

  • Adequate stairs with handrails. 1910.24(h). 1910.23(d)(1) <br>

  • Adequate walkways and guardrails. 1910.23(c)(1) <br>

  • Guardrails installed on all raised platforms, walkways, etc above 48” 1910.23(c)(1). 1910.23(d)(1) <br>

  • Walkways free from obstruction and/or damage. 1910.23(c)(1) <br> <br>

  • All unused floor holes covered. 1910.23(a)(8). 1910.23(a)(9) <br>

  • Guardrails provided on crossovers. 1910.23(c)(1) <br>

  • “PPE Required” warning signs erected. (grouped or individual signs). 1910.145(c)(2)(i). 1910.145(c)(3) <br>

  • Warning signs clean and visible <br>1910.1200(f)(9) <br>

  • Chemical hazard warning signs erected. 1910.145(c)(2)(i) <br>

  • Shale shaker properly guarded. 1910.23(c)(3) <br>

  • Agitator shafts & couplings properly guarded. 1910.219(c)(2)(i) <br>

  • Mud guns properly secured. RP54 9.11.2 <br>

  • Jetting hoses properly secured. RP54 9.11.2 <br>

  • Adequate lighting provided. RP54 9.14.7 <br>

  • Approved lighting for the location installed. 1910.307(b)(1) <br>

  • Adequate personal protective equipment available: □ Rubber Gloves □ Apron □ Face Shield □ Goggles □ Respirator: □Other:________. RP54 5.2.4. RP54 6.13.2. 1910.132(a). 1910.133(a). 1910.134(a)(2). 1910.138(a)(1)<br>

  • Personal protective equipment properly maintained and in a clean & sanitary condition. RP54 6.13.2. 1910.132(a). 1910.134(h)(1) <br>

  • Personal protective equipment properly stored. RP54 6.13.2. 1910.132(a). 1910.134(h)(2)(i) <br>

  • General Housekeeping. 1910.22(a)(1). RP54 6.5.1 <br> <br>

  • Electric wiring in good condition. 1910.303(b)(1-2). 1910.303(c) <br>

  • Explosion proof equipment, fixtures and wiring used in the vicinity of the shale shaker. Class 1 Div 1/2 Location. 1910.307(b)(1-3) & subsections. 1910.307(c). RP500 5.3. RP500 10.1-16 RP 54 9.14.8 <br>

  • All pits grounded. <br>RP54 6.1.16 <br>

  • General :

GENERATOR AND ELECTRICAL SYSTEMS

  • Moving parts guarded. 1910.212(a)(1) <br>

  • Generators properly grounded. RP54 9.14.11 <br>

  • Cover panels on electrical control boxes installed and closed. . 1910.305(b)(2). 1910.335(a)(2)(ii) <br>

  • All electrical controls marked as to their function and legible. 1910.303(f) <br>

  • Warning signs clean and visible <br>1910.1200(f)(9) <br>

  • “HIGH VOLTAGE” warning signs erected. 1910.145(c)(2)(i). 1910.305(b)(2)(ii) <br>

  • Insulating mats available at electrical panels. 1910.335(a)(2)(ii) <br>

  • Condition of electrical wiring 1910.303(b)(1-2)<br>

  • Electrical wiring/fixtures/etc approved for the location (Cl 1 Div 1 or 2 location) (Based on worst condition scenario), RP54 10.2.1, 1910.307(b)(1-2), RP500 5.3, RP500 6.1-2

  • Electrical wires properly strung. 1910.305(a)(2)(iii). RP54 10.2.3<br>

  • Wires not running along the ground, RP54 10.2.3, 1910.305(a)(1)(iii)(G) <br> <br>

  • Electrical cords, fixed or extension, not run through doorways. 1910.305(a)(2)(iii)(G). 1910.305(g)(1)(iii)(C) <br>

  • Unused electrical outlets covered <br>1910.305(b)(1-3)<br>

  • Receptacles and plugs in good condition. 1910.303(b)(1)<br>

  • Air compressors properly guarded. 1910.212(a)(1) <br>

  • Air storage tanks equipped with pop-off valve. 1910.169(b)(3)(i-iv) <br>

  • “Hearing Protection Required” warning signs erected. 1910.145(c)(2)(i) <br>

  • Hearing protection available. 1910.95(a) <br>

  • Adequate lighting installed, RP54 9.14.7, RP54 9.14.4, 1910.303(h)(3)(ii), 1910.303(g)(1)(v) <br>

  • All light fixtures properly protected from damage. 1910.307(b)(1-2) <br>

  • Approved lighting for the location provided., (Class 1 Div 2 Location under worst case condition) 1910.307(b)(1), RP54 9.14.10, RP500 5.3 <br>

  • General Housekeeping, RP54 6.5.1 <br>

  • Water hose used for washing area kept away from generator skid <br> <br>

  • Generator doors props properly pinned<br> <br>

  • Fire extinguishers rated for electrical fires (B-C). 1910.157(d)(1) <br>

  • Fire extinguishers located properly. 1910.157(c)(1) <br>

  • General :

FIRE PROTECTION

  • B/C class fire extinguishers available. RP54 7.2.4. RP54 7.2.5 <br>

  • Adequate number of fire extinguishers available. 1910.157(d)(2-6). RP54 7.2.4. RP54 7.2.5 <br>

  • Fire extinguishers properly charged. 1910.157(c)(4) <br>

  • Fire extinguishers with equipped with gauges. 1910.157(c)(4) <br>

  • Fire extinguishers properly located and in/at their assigned locations. 1910.157(c)(1), 1910.157(c)(4), RP54 6.5.5, RP54 7.2.2. RP54 12.1.3

  • Flammables stored properly. 1910.106(d)(2), RP54 8.1.1 <br>

  • Flare area, if present, is clear of combustibles. RP53 15.11, RP49 8.2.6, RP68 8.2.8 <br>

  • Flare Lines & Flare Stack location based on prevailing wind direction., RP49 8.2.6, RP68 8.2.8 <br>

  • Fire extinguishers tagged and/or inspection. 1910.157(e)(1-5), RP54 7.2.3, RP54 7.2.7<br>

  • General :

BOTTOM DOG HOUSE

  • General housekeeping. RP54 6.5.1, 1910.22(a)(1) <br>

  • Appropriate lighting installed. 1910.307(b)(1), RP500 5.3, RP500 10.1-16 <br>

  • Condition of electrical wiring. 1910.303(b)(1-2) <br>

  • Cover panels on electrical control boxes installed and closed. 1910.305(b)(2). 1910.335(a)(2)(ii) <br>

  • Electrical wires properly strung. 1910.305(a)(2)(iii). RP54 10.2.3<br>

  • Electrical cords, fixed or extension, not run through doorways. 1910.305(a)(2)(iii)(G). 1910.305(g)(1)(iii)(C) <br>

  • Receptacles and plugs in good condition. <br>1910.303(b)(1) <br>

  • Warning signs clean and visible <br>1910.1200(f)(9) <br>

  • Dog house properly grounded .

  • General :

FUEL & OTHER FLAMMABLE LIQUID STORAGE TANKS & NON-FLAMMABLE STORAGE TANK

  • Warning signs clean and visible <br>1910.1200(f)(9) <br>

  • Fuel storage tanks properly located! RP 54 8.3.5, 1910.106(b) <br>

  • Discharge hoses in good condition, 1910.106(b) <br>

  • Discharge valves in good condition. 1910.106(b) <br>

  • LPG storage tanks and compressed gas cylinders in good condition, 1910.106(b), RP54 8.3.8 <br>

  • Piping and fuel lines in good condition. 1910.106(b) <br>

  • Stationary ladders on storage tanks in good condition. 1910.27(f) <br>

  • Adequate lighting provided. RP54 9.14.7 <br>

  • Fuel tanks properly labeled on all sides. RP54 8.4.1d. 1910.1200(f)(4-5) <br>

  • “Flammable” warning signs erected on all sides. 1910.145(c)(2)(i). 1910.1200(f)(5-6). RP54 7.1.2-6. RP54 8.4.1d <br>

  • Vapor release vents elevated & away from ignition sources. 1910.106(b)(2)(iv)(c). 1910.106(b)(2)(v)(g) <br>

  • General housekeeping. RP54 6.5.1. 1910.22(a)(1) <br>

  • B/C Class fire extinguisher available and identified. RP54 8.4.1e. 1910.157(c)(1). 1910.157(d)(1) <br>

  • Contents of NON-FLAMMABLE storage tanks identified on all sides of tank(s) (WATER TANKS)

  • Fuel tank properly grounded.

  • General :

​PIPE RACK AREA

  • Ends of pipe racks properly chocked, 1910.176(b), RP54 9.12.3 <br>

  • Spacers used to separate layers of pipe. 1910.176(b). RP54 9.12.5 <br>

  • Pipe racks are level and stable

  • Pipe rack catwalk in good condition

  • V-door slide in good condition

  • Employees not permitted on top of pipe

  • General housekeeping, 1910.176(c), RP54 6.5.1 <br>

  • General :

​BLOW-OUT PREVENTERS

  • BOP properly installed. RP54 6.4.1 <br>

  • BOP stack properly stabilized. RP54 6.4.10 <br>

  • Wheels and stems in place, if automatic device is not available. <br> <br>

  • All hydraulic lines connected RP54 6.4.18 <br>

  • Hydraulic lines protected. RP53 12.5.2 <br>

  • Accumulator unit properly located. RP54 7.2.2 <br>

  • Warning signs clean and visible <br>1910.1200(f)(9) <br>

  • Accumulator bottles labeled with contents. 1910.1200(f)(5-6) <br>

  • Accumulator valves in appropriate position, open or closed. RP54 7.2.2 <br>

  • Accumulator valves identified as to purpose and position. RP54 7.2.2 RP53 12.5.3f <br>

  • Accumilator properly grounded.

  • Gauges properly installed & located, RP53 8.2i <br>

  • Choke manifold and line secured. RP54 6.4.18 <br>

  • Choke manifold accessible. RP53 8.2c <br>

  • General housekeeping. RP54 6.5.1, 1910.22(a)(1) <br>

  • Suitcase properly grounded.

  • Wireline machine properly guarded.

  • Wireline properly labeled with correct warning signs .

  • Cover panels on wireline control boxes installed and closed. 1910.305(b)(2). 1910.335(a)(2)(ii) <br>

  • Condition of electrical wiring on wireline. 1910.303(b)(1-2) <br>

  • Electrical wires properly strung. 1910.305(a)(2)(iii). RP54 10.2.3<br>

  • General :

DERRICK & SUBSTRUCTURE

  • Derrick/A-Frame assembly pins in place. RP54 9.2.8 <br>

  • Assembly pins secured with keepers. RP54 9.2.8 <br>

  • Substructure assembly pins in place. RP54 9.2.8 <br>

  • Substructure assembly pins secured with keepers. RP54 9.2.8 <br>

  • Manufacturer’s specification/operation plate attached to derrick. RP54 9.2.2 <br>

  • Warning signs clean and visible <br>1910.1200(f)(9) <br>

  • Damage and/or corrosion to derrick (waste metal). RP54 9.16.1 <br>

  • Damage and/or corrosion to substructure (waste metal). RP54 9.16.1 <br>

  • Condition of derrick ladder. RP54 9.3.1-2 <br>

  • Climb assist device available. 1910.27(d)(5) <br>

  • Climb assist device in safe condition. 1910.27(d)(5)<br>

  • Full body harness with lanyard available. 1910.132(c), RP54 5.5.1 <br>

  • Full body harness w/ lanyard in safe condition. 1910.132(c), RP54 5.5.1<br>

  • Fall protection devices in use. 1910.132(c), RP54 5.5.1 <br>

  • Condition of fall protection device. SRL

  • “Fall Protection Required” warning signs erected. 1910.145(c)(2)(i) <br>

  • Derrick/Tubing boards in safe condition. RP54 9.2.17<br>

  • Guardrails installed on derrick board. RP54 9.3.17, RP54 5.5.1 <br> <br>

  • Crown guardrails installed. RP54 9.3.17, 1910.23(c)(1) <br>

  • Derrick locking pins in place with safety pins, RP54 9.2.8 <br>

  • Booms and boom lines in good condition <br> <br>

  • Adequate lighting provided. RP54 9.14.7 <br>

  • Approved lighting for the location installed. 1910.307(b)(1), RP500 5.3, RP500 10.1-16 <br>

  • Condition of electrical wiring. 1910.303(b)(1-2) <br>

  • Electrical wires properly strung. 1910.305(a)(2)(iii). RP54 10.2.3<br>

  • Derrick stand and ladder in good condition. 1910.27 <br>

  • Derrick emergency escape line installed. RP54 6.10.1 <br>

  • Geronimo on-line and ready for immediate access and use. RP54 6.10.1 <br>

  • Emergency escape line adequately anchored, in a clear area away from the rig. RP54 6.10.1 <br> <br>

  • Mud standpipe secured <br> <br>

  • Mudhose snubbed at both ends <br> <br>

  • Rotary beams and all braces are in good condition <br> <br>

  • Dead end of drilling line anchored RP9B 3.3.9 <br>

  • Drilling line hung properly from spool to sub structure. <br> <br>

  • BOP pick up line hung properly up off ground.

  • Condition of BOP pick up line.

  • General :

Top Dog House

  • OSHA poster posted 1903.2(a)(1) <br> <br> <br>

  • First aid kit available in drill floor doghouse and properly stocked. 1910.151(b) <br>

  • Warning signs clean and visible <br>1910.1200(f)(9) <br>

  • Appropriate lighting installed. 1910.307(b)(1), RP500 5.3, RP500 10.1-16 <br>

  • General housekeeping. RP54 6.5.1, 1910.22(a)(1) <br>

  • Minimum 2 exits from drill floor doghouse. 1910.36(b)(1) <br>

  • Emergency phone numbers posted <br>RP54 4.2.1 <br>RP49 7.6 <br>RP68 7.7 <br>

  • Emergency response plan. <br>1910.38(b) <br>1910.120(q)(1-2) <br>RP49 7.3-8 <br>RP68 7.3-9 <br>

  • MSDS’s available and accessible at all times <br>RP54 6.1.12 <br>1910.1200(g)(1) <br>

  • Emergency escape air packs are readily and quickly available, if applicable <br>1910.134(d)(2)(i) <br>RP49 6.6.2 <br>RP68 6.5.1, 6.7 <br>

  • Emergency escape air packs properly maintained and fully charged <br>RP49 6.6.2 <br>RP 68 6.5.1, 6.7 <br>

  • H2S monitoring equipment properly maintained & calibrated <br>RP49 6.5 <br>RP68 6.4 <br>

  • Condition of electrical wiring. 1910.303(b)(1-2) <br>

  • Cover panels on electrical control boxes installed and closed. 1910.305(b)(2). 1910.335(a)(2)(ii) <br>

  • Electrical wires properly strung. 1910.305(a)(2)(iii). RP54 10.2.3 <br>

  • Electrical cords, fixed or extension, not run through doorways. 1910.305(a)(2)(iii)(G). 1910.305(g)(1)(iii)(C) <br>

  • Receptacles and plugs in good condition. <br>1910.303(b)(1) <br>

  • Floor plate in good condition. <br> <br>

  • General :

​DRILL FLOOR AREA

  • Rotary floor in good condition <br> <br>

  • Rotary chain drive guarded. 1910.212(a)(1-3) <br>

  • <br>All unused floor holes covered. 1910.23(a)(8-9), RP54 9.1.1., RP54 9.3.20., RP54 9.3.21 <br>

  • Driller at or near controls. RP54 9.4.4 <br>

  • Drillers controls properly labeled/identified <br> <br>

  • Weight indicator installed. RP54 9.10.1 <br>

  • Weight indicator visible to brake operator. RP54 9.10.3 <br>

  • Warning signs clean and visible <br>1910.1200(f)(9) <br>

  • Pipe slips & Dies in good condition. RP54 9.9.2 <br>

  • Tong body & jaws in good condition. RP54 9.9.7 <br> <br> <br>

  • Tong dies sharp. RP54 9.9.7 <br>

  • Tong die keeper used. RP54 9.9.7 <br>

  • Tong snubbing lines in good condition. RP54 9.9.6 <br>

  • Tong snubbing line clamps in good condition and installed properly. <br> <br>

  • Tong vertical support line clamps in good condition and installed properly. RP9B 3.7.4 <br>

  • Condition of tong jerk line(s) RP54 9.9.6 <br>

  • Racking floor area in good condition

  • V-door gate or chain provided and in place. 1910.23(c)(1) <br>

  • Air hoist line in safe condition. RP9B 3.2.7<br>

  • Air hoist line guide in operating condition <br> <br>

  • Air hoist line properly layed/wound on drum. RP9B 3.3.3 <br>

  • Air hoist properly guarded. 1910.212(a)(1)<br>

  • Cathead friction surface in good condition. RP54 9.5.1 <br>

  • Cathead line divider/grip in good condition

  • Catline not worn or kinked, if available. RP54 9.5.10 <br>

  • Spinning chain in good condition <br> <br>

  • Headache post in good condition. RP54 9.5.8 <br> <br>

  • Anti-crown device ( Crown-o-matic) installed and operational. RP54 9.2.16. RP54 9.4.8 <br>

  • Sufficient wraps left on drum with blocks in down position. RP9B 3.3.10(b) <br>

  • Proper lay of drill line on reel. RP9B 3.3.10(b) <br>

  • Drilling line in good condition. RP9B 3.3.3. RP9B 3.3.10 <br>

  • Drawworks properly guarded. RP54 9.4.2, RP54 9.6.4 <br>

  • Adequate lighting provided. RP54 9.14.7 <br>

  • Appropriate lighting installed. 1910.307(b)(1), RP500 5.3, RP500 10.1-16 <br>

  • General housekeeping. RP54 6.5.1, 1910.22(a)(1) <br>

  • Guardrails, Midrails, & Toeboards installed along all open side edges of floor. 1910.23(c)(1) RP54 9.3.17<br>

  • Adequate stairs provided off rig floor. RP54 9.3.10. 1910.24(b)<br>

  • Stair treads not damaged. RP54 9.3.11 <br>

  • General :

​POWER AND HAND TOOLS

  • Condition of hand tools. RP54 6.8.6 <br>

  • Hand tools stored properly

  • Bench grinder wheels properly guarded. 1910.215(b) <br>

  • Bench grinder rest spacing – 1/8” from wheel. 1910.215(b)(4) <br>

  • Electrical extension cords properly insulated. RP54 9.14.5. 1910.305(g)(2)(ii) <br>

  • Plugs of electrical extension cords in good condition. RP54 9.14.5. 1910.304(f)(4) 1910.305(g)(2)(iii) <br>

  • General :

HOISTING TOOLS, HOOKS, BAILS, ELEVATORS AND OTHER RELATED EQUIPMENT

  • Traveling blocks in good condition. RP54 9.7.1 <br>

  • Traveling blocks properly guarded. RP54 9.7.4 <br>

  • Sheave guards in good condition <br> <br>

  • Bales and/or links in good condition. RP54 9.7.1 <br>

  • Elevators in good condition. RP54 9.7.1. RP54 9.7.8 <br>

  • Hoisting hook equipped with safety latch or equiv. RP54 9.7.3 <br>

  • Circulating hose secured to gooseneck and swivel. RP54 9.7.7 <br>

  • General :

Signatures

  • Inspected by

  • Reviewed with

  • Select date

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.