Information
-
WELL NUMBER
-
Robinson Drilling Rig Inspection
-
RIG #.
-
Conducted on
-
Prepared by
-
Location
DRILL SITE LOCATION
-
Authorized Personnel Sign Posted at entrance to site<br>1910.145(c)(2)(i)<br>RP54 7.1.2-3<br>Hard Hat/Safety Glasses/Steel Toe Shoe Signs Posted at prominent locations on site<br>191t0.145(c)(3)<br>No Smoking Area’s Designated & Posted. RP54 7.1.2-3. 1910.145(c)(2)(i)<br>
-
Visible rig identification sign erected at entrance to site road and at all directional changes on site road (for 911 services) <br> 1910.151(a) <br>
-
H2S/SO2 warning signs erected, if applicable, at entrance to site and at other prominent locations on site <br> <br>1910.145(c)(2)(i) <br>1910.1000(e) <br>1910.1200(f)(5-6) <br>RP54 7.1.2-3 <br>RP49 5.1 <br>RP68 6.9 <br>
-
Escape line flagged with visible material <br>RP4G 14.5.f <br>
-
Outhouse/restroom facility provided or in close proximity to the site. (LT 10 min travel time or 2 miles, whichever is less) (Facility in close proximity only applies if the site is active for less than 1 day) <br>1910.141(c)(1)(i) <br>
-
Outhouse clean and sanitary, if provided. <br>1910.142(d)(10) <br>
-
Toolpusher’s trailer grounded <br>RP54 6.1.16 <br>
-
Housekeeping <br> 1910.22(a)(1) <br>RP54 6.5.1 <br>
-
Muster area designated. 1910.38(c)(4)<br>1910.145(c)(3)
-
Warning signs clean and visible <br>1910.1200(f)(9) <br>
-
Supply storage house clean <br>1910.22(a)(1) <br>RP54 6.5.1 <br>
-
Wind Sock available. <br>RP49 8.2.3 <br>RP68 6.8, 8.2.4 <br>
-
General :
PPE & GENERAL SAFETY
-
Pre-Job safety meeting held. RP54 6.1.7 <br>
-
Proper clothing worn by crew (No loose clothing). <br> RP54 5.2.5 <br>RP54 5.2.6 <br>1910.132(a) <br>
-
Hard hats used by crew <br>RP54 5.2.1 <br>1910.135(a)(1-2) <br>
-
Safety glasses used by crew <br>RP54 5.2.2 <br>1910.133(a)(1-5) <br>
-
Steel toed shoes used by crew <br>RP54 5.2.3 <br>1910.136(a) <br>
-
Hazardous jewelry not worn by crew <br>RP54 5.2.7 <br>
-
No Smoking rules observed <br> RP54 7.1.3 <br>
-
General :
MUD PUMP AREA
-
Drive belts and shafts guarded and Rotating parts guarded<br> 1910.212(a)<br>1910.219(i)(2)<br>RP54 6.8.2-3<br>1910.219(e)(1-6)<br>1910.219(c)(2)(i)<br>
-
Pony rods guarded <br>RP54 6.8.2-3 <br>1910.212(a) <br>
-
Head and valve covers fully bolted <br> <br> <br> <br>
-
Shear pin pop-off valve present and covered <br>1910.169(b)(3)(i-iv) RP54 9.13.11 <br>
-
Ends of mud vibrator hose snubbed <br> <br>
-
Pressure relief valves properly set<br>1910.169(b)(3)(i-iv)<br>RP54 9.13.2<br>
-
Discharge lines from relief valves are anchored RP 54 9.13.2 <br>
-
Ends of relief lines, high pressure lines, etc secured <br>RP54 9.13.3 <br>
-
Warning signs clean and visible <br>1910.1200(f)(9) <br>
-
General housekeeping of the area. RP54 6.5.1, 1910.22(a)(1)<br>
-
Adequate lighting provided <br>RP54 9.14.7 <br>
-
Approved lighting for the location available <br>1910.307(b)(1) RP500 5.3 RP500 10.1-16 <br>
-
Pumps, piping, hoses, valves and other fittings are maintained in good operating condition. RP54 9.13.4 <br>
-
General :
MUD MIXING AREA
-
Bagged material properly stacked. 1910.176(b) <br>
-
Adequate personal protective equipment available: □ Rubber Gloves □ Apron □ Face Shield □ Goggles <br>□ Respirator: □ Other:________. RP54 5.2.4. RP54 6.13.2. 1910.132(a). 1910.133(a). 1910.134(a)(2). 1910.138(a)(1) <br> <br> <br> <br>
-
Personal protective equipment properly stored and protective equipment properly maintained and in a clean & sanitary condition. RP54 6.13.2 1910.132(a) 1910.134(h)(1)<br>. RP54 6.13.2. 1910.132(a). 1910.134(h)(2)(i)<br>
-
“PPE Required” warning signs erected (Grouped or individual signs)<br> 1910.145(c)(3)<br>
-
Warning signs clean and visible <br>1910.1200(f)(9) <br>
-
Eye wash/shower station available in close proximate area to hazard 1910.151(c) Z358.1 5.4.2 RP54 4.4.1<br>
-
Eye wash/emergency shower access free from obstructions. Z358.1 5.4.2 <br>
-
Eye wash station/emergency shower in working order 1910.151(c) <br>
-
Eye wash station/emergency shower providing clean water supply. 1910.141(b)(1)(i) 1910.141(a)(3)(hi)<br>
-
Approved lighting for the location available. 1910.307(b)(1) RP500 5.3. RP500 10.1-16 <br>
-
Adequate lighting provided. RP54 9.14.7 <br>
-
General housekeeping RP54 6.5.1. 1910.22(a)(1) <br>
-
General :
MUD TANKS AND PITS
-
Adequate stairs with handrails. 1910.24(h). 1910.23(d)(1) <br>
-
Adequate walkways and guardrails. 1910.23(c)(1) <br>
-
Guardrails installed on all raised platforms, walkways, etc above 48” 1910.23(c)(1). 1910.23(d)(1) <br>
-
Walkways free from obstruction and/or damage. 1910.23(c)(1) <br> <br>
-
All unused floor holes covered. 1910.23(a)(8). 1910.23(a)(9) <br>
-
Guardrails provided on crossovers. 1910.23(c)(1) <br>
-
“PPE Required” warning signs erected. (grouped or individual signs). 1910.145(c)(2)(i). 1910.145(c)(3) <br>
-
Warning signs clean and visible <br>1910.1200(f)(9) <br>
-
Chemical hazard warning signs erected. 1910.145(c)(2)(i) <br>
-
Shale shaker properly guarded. 1910.23(c)(3) <br>
-
Agitator shafts & couplings properly guarded. 1910.219(c)(2)(i) <br>
-
Mud guns properly secured. RP54 9.11.2 <br>
-
Jetting hoses properly secured. RP54 9.11.2 <br>
-
Adequate lighting provided. RP54 9.14.7 <br>
-
Approved lighting for the location installed. 1910.307(b)(1) <br>
-
Adequate personal protective equipment available: □ Rubber Gloves □ Apron □ Face Shield □ Goggles □ Respirator: □Other:________. RP54 5.2.4. RP54 6.13.2. 1910.132(a). 1910.133(a). 1910.134(a)(2). 1910.138(a)(1)<br>
-
Personal protective equipment properly maintained and in a clean & sanitary condition. RP54 6.13.2. 1910.132(a). 1910.134(h)(1) <br>
-
Personal protective equipment properly stored. RP54 6.13.2. 1910.132(a). 1910.134(h)(2)(i) <br>
-
General Housekeeping. 1910.22(a)(1). RP54 6.5.1 <br> <br>
-
Electric wiring in good condition. 1910.303(b)(1-2). 1910.303(c) <br>
-
Explosion proof equipment, fixtures and wiring used in the vicinity of the shale shaker. Class 1 Div 1/2 Location. 1910.307(b)(1-3) & subsections. 1910.307(c). RP500 5.3. RP500 10.1-16 RP 54 9.14.8 <br>
-
All pits grounded. <br>RP54 6.1.16 <br>
-
General :
GENERATOR AND ELECTRICAL SYSTEMS
-
Moving parts guarded. 1910.212(a)(1) <br>
-
Generators properly grounded. RP54 9.14.11 <br>
-
Cover panels on electrical control boxes installed and closed. . 1910.305(b)(2). 1910.335(a)(2)(ii) <br>
-
All electrical controls marked as to their function and legible. 1910.303(f) <br>
-
Warning signs clean and visible <br>1910.1200(f)(9) <br>
-
“HIGH VOLTAGE” warning signs erected. 1910.145(c)(2)(i). 1910.305(b)(2)(ii) <br>
-
Insulating mats available at electrical panels. 1910.335(a)(2)(ii) <br>
-
Condition of electrical wiring 1910.303(b)(1-2)<br>
-
Electrical wiring/fixtures/etc approved for the location (Cl 1 Div 1 or 2 location) (Based on worst condition scenario), RP54 10.2.1, 1910.307(b)(1-2), RP500 5.3, RP500 6.1-2
-
Electrical wires properly strung. 1910.305(a)(2)(iii). RP54 10.2.3<br>
-
Wires not running along the ground, RP54 10.2.3, 1910.305(a)(1)(iii)(G) <br> <br>
-
Electrical cords, fixed or extension, not run through doorways. 1910.305(a)(2)(iii)(G). 1910.305(g)(1)(iii)(C) <br>
-
Unused electrical outlets covered <br>1910.305(b)(1-3)<br>
-
Receptacles and plugs in good condition. 1910.303(b)(1)<br>
-
Air compressors properly guarded. 1910.212(a)(1) <br>
-
Air storage tanks equipped with pop-off valve. 1910.169(b)(3)(i-iv) <br>
-
“Hearing Protection Required” warning signs erected. 1910.145(c)(2)(i) <br>
-
Hearing protection available. 1910.95(a) <br>
-
Adequate lighting installed, RP54 9.14.7, RP54 9.14.4, 1910.303(h)(3)(ii), 1910.303(g)(1)(v) <br>
-
All light fixtures properly protected from damage. 1910.307(b)(1-2) <br>
-
Approved lighting for the location provided., (Class 1 Div 2 Location under worst case condition) 1910.307(b)(1), RP54 9.14.10, RP500 5.3 <br>
-
General Housekeeping, RP54 6.5.1 <br>
-
Water hose used for washing area kept away from generator skid <br> <br>
-
Generator doors props properly pinned<br> <br>
-
Fire extinguishers rated for electrical fires (B-C). 1910.157(d)(1) <br>
-
Fire extinguishers located properly. 1910.157(c)(1) <br>
-
General :
FIRE PROTECTION
-
B/C class fire extinguishers available. RP54 7.2.4. RP54 7.2.5 <br>
-
Adequate number of fire extinguishers available. 1910.157(d)(2-6). RP54 7.2.4. RP54 7.2.5 <br>
-
Fire extinguishers properly charged. 1910.157(c)(4) <br>
-
Fire extinguishers with equipped with gauges. 1910.157(c)(4) <br>
-
Fire extinguishers properly located and in/at their assigned locations. 1910.157(c)(1), 1910.157(c)(4), RP54 6.5.5, RP54 7.2.2. RP54 12.1.3
-
Flammables stored properly. 1910.106(d)(2), RP54 8.1.1 <br>
-
Flare area, if present, is clear of combustibles. RP53 15.11, RP49 8.2.6, RP68 8.2.8 <br>
-
Flare Lines & Flare Stack location based on prevailing wind direction., RP49 8.2.6, RP68 8.2.8 <br>
-
Fire extinguishers tagged and/or inspection. 1910.157(e)(1-5), RP54 7.2.3, RP54 7.2.7<br>
-
General :
BOTTOM DOG HOUSE
-
General housekeeping. RP54 6.5.1, 1910.22(a)(1) <br>
-
Appropriate lighting installed. 1910.307(b)(1), RP500 5.3, RP500 10.1-16 <br>
-
Condition of electrical wiring. 1910.303(b)(1-2) <br>
-
Cover panels on electrical control boxes installed and closed. 1910.305(b)(2). 1910.335(a)(2)(ii) <br>
-
Electrical wires properly strung. 1910.305(a)(2)(iii). RP54 10.2.3<br>
-
Electrical cords, fixed or extension, not run through doorways. 1910.305(a)(2)(iii)(G). 1910.305(g)(1)(iii)(C) <br>
-
Receptacles and plugs in good condition. <br>1910.303(b)(1) <br>
-
Warning signs clean and visible <br>1910.1200(f)(9) <br>
-
Dog house properly grounded .
-
General :
FUEL & OTHER FLAMMABLE LIQUID STORAGE TANKS & NON-FLAMMABLE STORAGE TANK
-
Warning signs clean and visible <br>1910.1200(f)(9) <br>
-
Fuel storage tanks properly located! RP 54 8.3.5, 1910.106(b) <br>
-
Discharge hoses in good condition, 1910.106(b) <br>
-
Discharge valves in good condition. 1910.106(b) <br>
-
LPG storage tanks and compressed gas cylinders in good condition, 1910.106(b), RP54 8.3.8 <br>
-
Piping and fuel lines in good condition. 1910.106(b) <br>
-
Stationary ladders on storage tanks in good condition. 1910.27(f) <br>
-
Adequate lighting provided. RP54 9.14.7 <br>
-
Fuel tanks properly labeled on all sides. RP54 8.4.1d. 1910.1200(f)(4-5) <br>
-
“Flammable” warning signs erected on all sides. 1910.145(c)(2)(i). 1910.1200(f)(5-6). RP54 7.1.2-6. RP54 8.4.1d <br>
-
Vapor release vents elevated & away from ignition sources. 1910.106(b)(2)(iv)(c). 1910.106(b)(2)(v)(g) <br>
-
General housekeeping. RP54 6.5.1. 1910.22(a)(1) <br>
-
B/C Class fire extinguisher available and identified. RP54 8.4.1e. 1910.157(c)(1). 1910.157(d)(1) <br>
-
Contents of NON-FLAMMABLE storage tanks identified on all sides of tank(s) (WATER TANKS)
-
Fuel tank properly grounded.
-
General :
PIPE RACK AREA
-
Ends of pipe racks properly chocked, 1910.176(b), RP54 9.12.3 <br>
-
Spacers used to separate layers of pipe. 1910.176(b). RP54 9.12.5 <br>
-
Pipe racks are level and stable
-
Pipe rack catwalk in good condition
-
V-door slide in good condition
-
Employees not permitted on top of pipe
-
General housekeeping, 1910.176(c), RP54 6.5.1 <br>
-
General :
BLOW-OUT PREVENTERS
-
BOP properly installed. RP54 6.4.1 <br>
-
BOP stack properly stabilized. RP54 6.4.10 <br>
-
Wheels and stems in place, if automatic device is not available. <br> <br>
-
All hydraulic lines connected RP54 6.4.18 <br>
-
Hydraulic lines protected. RP53 12.5.2 <br>
-
Accumulator unit properly located. RP54 7.2.2 <br>
-
Warning signs clean and visible <br>1910.1200(f)(9) <br>
-
Accumulator bottles labeled with contents. 1910.1200(f)(5-6) <br>
-
Accumulator valves in appropriate position, open or closed. RP54 7.2.2 <br>
-
Accumulator valves identified as to purpose and position. RP54 7.2.2 RP53 12.5.3f <br>
-
Accumilator properly grounded.
-
Gauges properly installed & located, RP53 8.2i <br>
-
Choke manifold and line secured. RP54 6.4.18 <br>
-
Choke manifold accessible. RP53 8.2c <br>
-
General housekeeping. RP54 6.5.1, 1910.22(a)(1) <br>
-
Suitcase properly grounded.
-
Wireline machine properly guarded.
-
Wireline properly labeled with correct warning signs .
-
Cover panels on wireline control boxes installed and closed. 1910.305(b)(2). 1910.335(a)(2)(ii) <br>
-
Condition of electrical wiring on wireline. 1910.303(b)(1-2) <br>
-
Electrical wires properly strung. 1910.305(a)(2)(iii). RP54 10.2.3<br>
-
General :
DERRICK & SUBSTRUCTURE
-
Derrick/A-Frame assembly pins in place. RP54 9.2.8 <br>
-
Assembly pins secured with keepers. RP54 9.2.8 <br>
-
Substructure assembly pins in place. RP54 9.2.8 <br>
-
Substructure assembly pins secured with keepers. RP54 9.2.8 <br>
-
Manufacturer’s specification/operation plate attached to derrick. RP54 9.2.2 <br>
-
Warning signs clean and visible <br>1910.1200(f)(9) <br>
-
Damage and/or corrosion to derrick (waste metal). RP54 9.16.1 <br>
-
Damage and/or corrosion to substructure (waste metal). RP54 9.16.1 <br>
-
Condition of derrick ladder. RP54 9.3.1-2 <br>
-
Climb assist device available. 1910.27(d)(5) <br>
-
Climb assist device in safe condition. 1910.27(d)(5)<br>
-
Full body harness with lanyard available. 1910.132(c), RP54 5.5.1 <br>
-
Full body harness w/ lanyard in safe condition. 1910.132(c), RP54 5.5.1<br>
-
Fall protection devices in use. 1910.132(c), RP54 5.5.1 <br>
-
Condition of fall protection device. SRL
-
“Fall Protection Required” warning signs erected. 1910.145(c)(2)(i) <br>
-
Derrick/Tubing boards in safe condition. RP54 9.2.17<br>
-
Guardrails installed on derrick board. RP54 9.3.17, RP54 5.5.1 <br> <br>
-
Crown guardrails installed. RP54 9.3.17, 1910.23(c)(1) <br>
-
Derrick locking pins in place with safety pins, RP54 9.2.8 <br>
-
Booms and boom lines in good condition <br> <br>
-
Adequate lighting provided. RP54 9.14.7 <br>
-
Approved lighting for the location installed. 1910.307(b)(1), RP500 5.3, RP500 10.1-16 <br>
-
Condition of electrical wiring. 1910.303(b)(1-2) <br>
-
Electrical wires properly strung. 1910.305(a)(2)(iii). RP54 10.2.3<br>
-
Derrick stand and ladder in good condition. 1910.27 <br>
-
Derrick emergency escape line installed. RP54 6.10.1 <br>
-
Geronimo on-line and ready for immediate access and use. RP54 6.10.1 <br>
-
Emergency escape line adequately anchored, in a clear area away from the rig. RP54 6.10.1 <br> <br>
-
Mud standpipe secured <br> <br>
-
Mudhose snubbed at both ends <br> <br>
-
Rotary beams and all braces are in good condition <br> <br>
-
Dead end of drilling line anchored RP9B 3.3.9 <br>
-
Drilling line hung properly from spool to sub structure. <br> <br>
-
BOP pick up line hung properly up off ground.
-
Condition of BOP pick up line.
-
General :
Top Dog House
-
OSHA poster posted 1903.2(a)(1) <br> <br> <br>
-
First aid kit available in drill floor doghouse and properly stocked. 1910.151(b) <br>
-
Warning signs clean and visible <br>1910.1200(f)(9) <br>
-
Appropriate lighting installed. 1910.307(b)(1), RP500 5.3, RP500 10.1-16 <br>
-
General housekeeping. RP54 6.5.1, 1910.22(a)(1) <br>
-
Minimum 2 exits from drill floor doghouse. 1910.36(b)(1) <br>
-
Emergency phone numbers posted <br>RP54 4.2.1 <br>RP49 7.6 <br>RP68 7.7 <br>
-
Emergency response plan. <br>1910.38(b) <br>1910.120(q)(1-2) <br>RP49 7.3-8 <br>RP68 7.3-9 <br>
-
MSDS’s available and accessible at all times <br>RP54 6.1.12 <br>1910.1200(g)(1) <br>
-
Emergency escape air packs are readily and quickly available, if applicable <br>1910.134(d)(2)(i) <br>RP49 6.6.2 <br>RP68 6.5.1, 6.7 <br>
-
Emergency escape air packs properly maintained and fully charged <br>RP49 6.6.2 <br>RP 68 6.5.1, 6.7 <br>
-
H2S monitoring equipment properly maintained & calibrated <br>RP49 6.5 <br>RP68 6.4 <br>
-
Condition of electrical wiring. 1910.303(b)(1-2) <br>
-
Cover panels on electrical control boxes installed and closed. 1910.305(b)(2). 1910.335(a)(2)(ii) <br>
-
Electrical wires properly strung. 1910.305(a)(2)(iii). RP54 10.2.3 <br>
-
Electrical cords, fixed or extension, not run through doorways. 1910.305(a)(2)(iii)(G). 1910.305(g)(1)(iii)(C) <br>
-
Receptacles and plugs in good condition. <br>1910.303(b)(1) <br>
-
Floor plate in good condition. <br> <br>
-
General :
DRILL FLOOR AREA
-
Rotary floor in good condition <br> <br>
-
Rotary chain drive guarded. 1910.212(a)(1-3) <br>
-
<br>All unused floor holes covered. 1910.23(a)(8-9), RP54 9.1.1., RP54 9.3.20., RP54 9.3.21 <br>
-
Driller at or near controls. RP54 9.4.4 <br>
-
Drillers controls properly labeled/identified <br> <br>
-
Weight indicator installed. RP54 9.10.1 <br>
-
Weight indicator visible to brake operator. RP54 9.10.3 <br>
-
Warning signs clean and visible <br>1910.1200(f)(9) <br>
-
Pipe slips & Dies in good condition. RP54 9.9.2 <br>
-
Tong body & jaws in good condition. RP54 9.9.7 <br> <br> <br>
-
Tong dies sharp. RP54 9.9.7 <br>
-
Tong die keeper used. RP54 9.9.7 <br>
-
Tong snubbing lines in good condition. RP54 9.9.6 <br>
-
Tong snubbing line clamps in good condition and installed properly. <br> <br>
-
Tong vertical support line clamps in good condition and installed properly. RP9B 3.7.4 <br>
-
Condition of tong jerk line(s) RP54 9.9.6 <br>
-
Racking floor area in good condition
-
V-door gate or chain provided and in place. 1910.23(c)(1) <br>
-
Air hoist line in safe condition. RP9B 3.2.7<br>
-
Air hoist line guide in operating condition <br> <br>
-
Air hoist line properly layed/wound on drum. RP9B 3.3.3 <br>
-
Air hoist properly guarded. 1910.212(a)(1)<br>
-
Cathead friction surface in good condition. RP54 9.5.1 <br>
-
Cathead line divider/grip in good condition
-
Catline not worn or kinked, if available. RP54 9.5.10 <br>
-
Spinning chain in good condition <br> <br>
-
Headache post in good condition. RP54 9.5.8 <br> <br>
-
Anti-crown device ( Crown-o-matic) installed and operational. RP54 9.2.16. RP54 9.4.8 <br>
-
Sufficient wraps left on drum with blocks in down position. RP9B 3.3.10(b) <br>
-
Proper lay of drill line on reel. RP9B 3.3.10(b) <br>
-
Drilling line in good condition. RP9B 3.3.3. RP9B 3.3.10 <br>
-
Drawworks properly guarded. RP54 9.4.2, RP54 9.6.4 <br>
-
Adequate lighting provided. RP54 9.14.7 <br>
-
Appropriate lighting installed. 1910.307(b)(1), RP500 5.3, RP500 10.1-16 <br>
-
General housekeeping. RP54 6.5.1, 1910.22(a)(1) <br>
-
Guardrails, Midrails, & Toeboards installed along all open side edges of floor. 1910.23(c)(1) RP54 9.3.17<br>
-
Adequate stairs provided off rig floor. RP54 9.3.10. 1910.24(b)<br>
-
Stair treads not damaged. RP54 9.3.11 <br>
-
General :
POWER AND HAND TOOLS
-
Condition of hand tools. RP54 6.8.6 <br>
-
Hand tools stored properly
-
Bench grinder wheels properly guarded. 1910.215(b) <br>
-
Bench grinder rest spacing – 1/8” from wheel. 1910.215(b)(4) <br>
-
Electrical extension cords properly insulated. RP54 9.14.5. 1910.305(g)(2)(ii) <br>
-
Plugs of electrical extension cords in good condition. RP54 9.14.5. 1910.304(f)(4) 1910.305(g)(2)(iii) <br>
-
General :
HOISTING TOOLS, HOOKS, BAILS, ELEVATORS AND OTHER RELATED EQUIPMENT
-
Traveling blocks in good condition. RP54 9.7.1 <br>
-
Traveling blocks properly guarded. RP54 9.7.4 <br>
-
Sheave guards in good condition <br> <br>
-
Bales and/or links in good condition. RP54 9.7.1 <br>
-
Elevators in good condition. RP54 9.7.1. RP54 9.7.8 <br>
-
Hoisting hook equipped with safety latch or equiv. RP54 9.7.3 <br>
-
Circulating hose secured to gooseneck and swivel. RP54 9.7.7 <br>
-
General :
Signatures
-
Inspected by
-
Reviewed with
-
Select date