Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
Framing Members
-
Walls framed with correct thickness and layout (16" o.c)<br>
-
If wall is rated, are all rough in boxes treated with fire putty or correct assembly (verify if needed on 1 or 2 hr walls)?
-
Walls stopping above ceiling braced properly?<br>
-
Framing members are not in contact with ductwork or other vibration causing items?
-
Shaft walls sealed and fire sulked at joints?
-
Slip track in place at head of walls if needed?
-
Are door frames installed to correct swing and are double 20 ga. Studs installed (2nd floor only, first floor will be all 20 ga studs)
-
Are framed openings the correct size
-
Are control/expansion joints framed into the wall( no more than 30' apart on walls over 30' long) and horizontal control joints at floor lines where walls are taller than 1 story or in stairwells.
-
Are walls insulated tightly if required?
-
Are wall cavities clean and free of debris/garbage?
-
Are access panel locations and fire ext. locations defined and framed out?
-
Mech,elect and framing inspections completed?
-
If there is vapor barrier, has it been inspected?
-
Electrical, security,data, fire alarm,AV, and controls roughed in the walls?
-
Plumbing and hvac inspected and insulated if required?
-
Framing inspected
-
Backing installed for:<br>Casework<br>Shelving<br>Grab bars<br>Toilet accessories<br>Electrical panels<br>TVs<br>Countertops<br>Mirrors<br>Toilet partitions<br>Door bumpers<br>Handrails<br>Wood paneling and trim<br>Lab fixtures<br>Chalkboard/marker boards<br>Fire doors<br>Aluminum window systems