Information
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
1. Work Environment
-
Site safety signage erected and completed
-
Safety Co-ordination plan completed and onsite?
-
All trades have SWMS on hand?
-
Site fencing in place to prevent public access if required
-
Toilet onsite and has paper
-
Water available onsite
-
Rubbish bin onsite
-
Are contractors working in a safe manner?
-
Is site clean and trip free?
-
Are materials stored safe, tidy and free of trip hazards?
-
Switchboard tested and tagged?
-
Substandard rectification work:
2. Excavations / Foundations
-
Excavations over 1.5m in depth have been fenced?
-
Relevant authority notified where required?
-
Trench supports or walls battered
-
Operators licensed?
-
Reo caps to exposed reinforcing?
-
Are pier holes covered?
-
Substandard rectification work:
3.Working at Heights
-
Fall risks of 2m or more? (including voids, pits, and trenches)
-
Scaffold & guardrails provided for fall protection at heights over 2 metres
-
Floor & wall penetrations barricaded or covered
-
Ladders secured top and bottom for 2 story access and fixed ladder, not fold out
-
Stair well 2 story guard/webbing rails in place
-
Ladders trade related 120kg+ and in good condition
-
Any h frame scaffold 1.8m in height require handrails/ladder access
-
Roof edge protection in place
-
Scaffolding over 4 metres high must be checked monthly by a licensed Scaffolder and recorded
-
Toe boards fitted to scaffolding over 4 metres
-
Base boards secure
-
Substandard rectification work:
4. Plant and Equipment
-
Power tools, leads, RCD's tested and tagged?
-
Unsafe or damaged plant/equipment? (including missing or damaged guards)
-
RCD's protection devices being used?
-
Incorrect plant /equipment for job? (e.g. grinding discs for cutting)
-
Unsafe or incompatible attachments used with plant/equipment?
-
Are all operators licensed/trained?
-
Flashing lights & reversing alarms?
-
Lack of safe work instructions?
-
Substandard rectification work:
5. Ladders
-
Unsafe or damaged ladders?
-
Unsafe positioning of ladders?
-
Ladder not properly secured?
-
Ladder unsuitable for job? (e.g. metal ladder used for electrical work)
-
Ladders extend 1 metre past highest access point
-
Insulated ladders for electrical work
-
Substandard rectification work:
6. Electrical Hazards
-
Unsafe electrical leads? (damaged, out of test date or untested)
-
Lack of RCD protection?
-
Contact with overhead electrical lines?
-
Overloading outlets?
-
Earth leakage protection provided
-
Leads placed on ground or on metal structures?
-
Electrical equipment near water?
-
Electrical equipment near flammables?
-
Electrical leads that may be damaged from contact with moving machinery parts?
-
Electrical leads on work surfaces?
-
Substandard rectification work:
7. Personal Protective Equipment (PPE)
-
Does each worker have a white card?
-
Ear muffs/plugs being worn?
-
Eye protection being used
-
Safety footwear being worn?
-
Breathing masks being worn?
-
Harness being used if no fall protection?
-
Hard hats being worn where required?
-
First aid kits held be contractors?
-
UV protection (no singlets, sunscreen, hats)
-
Substandard rectification work:
Sign Off
-
On site representative