Information
-
Audit Title
-
Document No.
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
Emergency Contacts and Egress
-
Emergency contacts and phone numbers posted on each lab and storage area.<br>
-
Exits are free of obstructions and stored materials.
-
Emergency exits are not locked with slide bolts, dead bolts, padlocks, etc.
Fire Extinguisher
-
Accessible
-
Locations clearly visible as marked.
-
Monthly and annual inspections current.
-
Mounted.
-
Charged and seals in tact.
-
Correct for hazards present.
Safety Shower and Eyewash
-
Eyewash and/or safety shower present.
-
Eyewash and/or shower needed due to substances and compounds that have the capability of producing adverse effects on the health and safety of humans.
-
Not blocked - must be accessible within 10 seconds. Path of travel free of obstructions.
-
Locations clearly marked.
-
Weekly inspections and flushing current and documented.
-
Protective caps in place on eyewash.
Housekeeping
-
Counters and floors clean and clear of clutter.
-
A minimum of 28" egress is maintained.
-
Lab is free of trip hazards.
-
Equipment on benches is stable or secured.
-
Supplies stored in a stable and secure manner.
-
Sharps disposal container provided and clearly labeled.
-
No storage within 18 inches of sprinkler heads.
-
Hallways and exits are clear.
-
Moving parts on machinery are guarded.
-
No food storage in lab.
-
No chemical storage in food areas.
-
Refrigerators for food storage labeled "food only".
Compressed Gas
-
Cylinders secured in place.
-
Protective caps in place when not in immediate use.
-
Oxygen and flammable gasses stored separately (20 feet apart or fire wall in-between).
-
Manual shutoff valves provided at all points of supply and use.
-
Corrosive gasses stored no more than 6 months.
-
Pressure gauges and regulators are in place as appropriate an are not damaged.
Chemical Hygiene And Storage
-
Appropriate hazard warning signs posted on door and storage areas (e.g. Cancer Agent)
-
Chemical Hygiene Plan present in lab.
-
All containers labeled legibly with content and hazard warning.
-
Storage container in good condition: no rust, leakage, dents, or crystallization.
-
Glass storage containers are limited to 1 gallon size or smaller.
-
Peroxide forming chemicals labeled and dated upon receipt and opening.
-
Peroxide forming chemicals disposed of within 3-12 months after opening depending upon the compound.
-
Acid and bases are stored separately from solvents. Exception: Store acetic acid with solvents
-
Manufacturer expiration dates observed.
-
Water reactive chemicals stored away from water (liquid) and water (liquid) vapor.
-
Corrosive and flammable chemicals are stored below eye level.
-
Chemical containers are not stacked.
-
No more than 10 gallons or flammable liquid are stored outside a flammable liquid cabinet.
-
No more than 40 gallons of flammable liquid stored per lab.
-
All refrigerators and freezers labeled to indicate their suitability for flammable storage.
-
Carcinogenic and highly toxic chemicals stored in main compartment of refrigerator instead of door.
-
Carcinoens, reproductive toxins and highly toxic chemicals stored an used in a designated and labeled area. No open bench storage.
-
All chemicals must be stored in their chemical group. If multiple groups are on a shelf they must be separated by secondary containment.
-
Opened 5 gallon containers should be placed in secondary containment.
-
Explosion resistant refrigerators and freezers used for flammable liquids.
Ventilation
-
Hood sash is in working order - not stuck, broke or removed.
-
Equipment and materials are positioned and used at a minimum of 6" from the front of the hood.
-
Airfoils are not altered or removed.
-
Equipment or materials do not obstruct air flow.
-
Hood interior is clean, uncluttered and not used as permanent storage.
-
Annual hood certification present indicating face velocity is 100-120 fpm.
-
Arrows indicating the correct sash height posted.
-
Hood low flow alarms present and operational.
-
Perchloric Acid hoods labeled "For Perchloric Acid Operations Only".
Personal Protective Equipment (PPE)
-
Safety glasses/ eye protection available.
-
Lab coats and aprons available.
-
Face shields available for operations with appreciable splash hazards (e.g. handling acids)
-
Appropriate shoes worn (e.g. no sandals, no high heels)
-
Appropriate gloves available.
Biosafety
-
Annual certification of boisafety cabinet present.
-
Appropriate hazard warning signs posted on door and storage areas (e.g. Biohazard - Legionella Pneumophila)
-
All containers labeled so as to content and hazard.
-
Sharps containers provided and clearly labeled.
-
Biological waste containers labeled.
-
Municipal trash containers free of biohazardous waste.
Chemical Waste Management
-
Hazardous Waste Plan present.
-
Waste containers labeled with contents and start date.
-
Waste stored less than 90 days.
-
Waste containers closed and in good condition.
-
Secondary containment of wastes stored outside hood.
-
Municipal trash containers free of chemical waste.
Office Space
-
Office free of tripping hazards (e.g., cables, loose tiles, damaged carpet)
-
Electrical cords and plugs in good condition
-
Workstation set-up provides a minimum of 28" egress.
-
Office supplies stacked in a stable and secure manner.
-
Hallways and exits are clear.
-
No storage within 18 inches of the sprinkler heads.
-
Fire extinguisher mounted, accessible an inspected monthly and annually.
-
Coffee pot not placed on or near combustible material.
Building Condition
-
Unsealed holes or pen pipe/conduit through floors, ceilings, walls present.
-
Duct work is sealed.
-
Loose floor tile present.
-
Loose ceiling tiles present.
-
Chipping/peeling paint present.
-
Conduit/pipe extruding out of the middle of the floor.
-
Suspect friable asbestos.
-
Exposed Mastic.
-
Bugs/ rodents present (excluding bugs/rodents used for experiments)
Special or Unique Hazards
-
List special or unique hazard: