Title Page
-
Project
-
Unit Number
-
Conducted on
-
Conducted by
-
Document No.
First Fix
-
Type of Inspection - Measurement
-
Cabinets are installed to correct RLs or nominated heights
-
Type of Inspection - Measurement
-
Independent/free standing cabinets are installed to correct locations <br>(Check dimensions are parallel to opposing floor cabinets and line of sight to floor finishes)
-
Type of Inspection - Mechanical
-
All cabinets are securely fixed to the floor/wall
-
Type of Inspection - Measurement
-
Cabinets are plumb/level - plus or minus 2mm
-
Type of Inspection - Visual
-
Service penetrations are neatly cut or covered with flanges
-
Type of Inspection - Visual
-
All fillets/infills are installed
-
Type of Inspection - Visual
-
All shadow fillets are installed and caulked (if applicable)
-
Type of Inspection - Visual/Tactile
-
Rebates of multiple cabinets align to accommodate recess lighting
-
Type of Inspection - Measurement
-
There is sufficient clearance between recess lighting and wall linings
-
Type of Inspection - Measurement
-
Electrical cables have been pulled through cabinets in the correct locations
-
Type of Inspection - Visual
-
Finished panels are protected with coreflute, corner moulds or similar
Final Fix
-
Type of Inspection - Visual/Tactile
-
Cabinet doors and drawer fronts are aligned and not “lipping”
-
Type of Inspection - Visual/Measurement
-
Cabinet door and drawer fronts have consistent gaps no greater than 2 mm
-
Type of Inspection - Visual
-
Benchtops, splashbacks and wall unit end panels align
-
Type of Inspection - Visual
-
Integrated appliance panels have been fitted and adjusted
-
Type of Inspection - Visual
-
All kickboards have been fitted
-
Type of Inspection - Visual
-
All end panels have been fitted
-
Type of Inspection - Measurment
-
Benchtops have equal perimeter overhangs
-
Type of Inspection - Visual
-
All cabinetry hardware has been installed
-
Type of Inspection - Visual
-
All cabinetry accessories has been installed. eg Cutlery drawers
-
Type of Inspection - Visual
-
All internal shelving has been installed
-
Type of Inspection - Visual
-
All dot bumper stickers has been installed
-
Type of Inspection - Mechanical
-
Drawer units slide freely
-
Type of Inspection - Mechanical
-
Doors close freely
-
Type of Inspection - Visual
-
Screw heads are capped
-
Type of Inspection - Visual
-
All cabinetry is free of marks, chips, protruding screws, excessive glue etc.
-
Type of Inspection - Visual
-
Cabinets are swept or wiped out of excess dust or wood chips
-
Type of Inspection - Visual
-
Finished cabinets and benchtops are suitably protected with core-flute, corner moulds or similar
-
Additional Notes
-
Add signature