Information

  • DA and CC Number

  • Applicant / Client / Owner

  • Conducted on

  • Prepared by

  • Location

Consent Details

  • DA/CDC/CC No.

  • Address

Previous inspections

Onsite Inspection

  • Are there any outstanding items from previous inspections?

  • Are there any environmental controls stated in the development consent installed on site?

  • The following controls have been checked for compliance

  • Is the building under construction consistent with the consent and specifications including any modifications?

  • Have relevant conditions of the consent required to be incorporated in the construction of the building, been implemented

  • Have relevant BASIX commitments been implemented?

Component: Frame

  • Do the following components comply with the BCA, Engineers design and/or manufacturer's specifications?

  • Subfloors

  • Subfloor braces?

  • Timber preservative treatment/s (termite control) ?

  • Ant capping ?

  • Point load/bearing joists ?

  • Ventilation ?

  • Mechanical connections ?

  • Bolted connections ?

  • Timber sizes/spans ?

  • Solid blocking ?

  • Bearers and joists ?

  • Floors

  • Joists ?

  • Substrate fixing for membranes ?

  • Timber preservative treatment (termite control) ?

  • Timber sizes/spans ?

  • Point load/bearing joists ?

  • Timber beams ?

  • Steel beams ?

  • Walls

  • External bottom plate fastening ?

  • Internal bottom plate fastening ?

  • Bracing ?

  • Brace height ?

  • Brace fixing ?

  • Crippling of stud ?

  • Timber sizes/span ?

  • Framing notches/holes ?

  • Nail plates ?

  • Lintel size/ fixing/ support ?

  • Damp proof course/ flashings ?

  • Timber preservative treatment (termite control) ?

  • Roof

  • Pitch/type ?

  • Purlin fixing ?

  • Rafter straps/ concealed purlin cleats ?

  • Ceiling batten fixing ?

  • Truss spacing/tie downs ?

  • Secondary bracing, ceiling/roof ?

  • Steel Frame

  • Does the steel frame comply with the BCA / Engineers Design / Specifications ?

Component: Structural Steel

  • Do the following components comply with the BCA, Engineers design and/or manufacturer's specifications?

  • Has the structural steelwork been installed as per structural engineer's design?

  • Has the structural steelwork been connected and fastened as per structural engineer's design?

  • Have relevant conditions of the consent required to be incorporated in the construction of the building been implemented?

Component: Masonry

  • Do the following components comply with the BCA, Engineers design and/or manufacturer's specifications?

  • Suitable for location ?

  • Cavity ?

  • Perpends ?

  • Width ?

  • Cleanliness of cavity ?

  • Weepholes ?

  • Articulation joints ?

  • Fixing straps and tie down systems ?

  • Lintels ?

  • Damp proof membrane ?

  • Wall tiles, size/spacing ?

  • Mortar mix ?

  • Isolated piers ?

  • Flashing correctly installed (windows, doors, roofs, parapets, chimney) ?

SUMMARY

  • Result

  • Comments

  • Photos

  • Accredited Certifier

  • Conducted on

  • Signature

  • PO Box 155, Shellharbour City Centre 2529 -Phone 02 4221 6111 -Fax 02 4221 6016 -Email records@shellharbour.nsw.gov.au. -Web www.shellharbour.nsw.gov.au -DX 26402 Shellharbour City Centre

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.