Information
-
Audit Title
-
Client / Site
- IBVogt Solar Farm & BESS, Warley, Essex
- Ethical Power
- Other
-
Conducted on
-
Prepared by
-
Location
-
Contractor
-
Personnel
- Darren Blythin & Sunotec Site Manager
- IBV Site Manager
- Ethical Power Site Manager
- Other
Introduction
-
Scope of Works
- Construction of Solar Farm & BESS Station
- Construction of Solar Farm
- Construction of BESS Station
- Other
Scoring Overview
-
Below is a list of the categories assessed and score achieved
-
- Construction of Solar Farm & BESS Station
- Construction of Solar Farm
- Construction of BESS Station
- Other
General
-
Supervisor / Foreman at time of this inspection.
-
Weather conditions at time of this inspection (select all that apply).
- Clear Sky
- Cloudy
- Raining
- Windy
- Hazy
- Snow / Hail
- OTHER
-
Minimum temperature today?
-
Maximum temperature today?
-
Current activities being undertaken on site (select all that apply).
- Cable Laying
- Crane Workings
- Electrical Works
- Excavations
- Frameworks Erection
- General Construction Works
- General Sitework
- Housekeeping Works
- Mechanical Works
- Other
- Piling Frameworks
- Plant Movements
- Underground Works
01 Site Documentation
-
Is the Project Notifiable as required by CDM 2015?
-
Is the F10 on display?
-
IS the F10 accurate and in date?
-
Is there an Induction Register?
-
Is there a toolbox talk Register. Date of and subject of last TBT?
-
Are Risk Assessments / Method Statements for activities taking place valid, available & signed?
-
Is the required insurance displayed - Public Liability, Employers Liability, etc?
-
Is the Construction Phase Plan available and up to date?
-
Health & Safety Policy on display?
-
Environmental Policy on display?
-
Emergency contacts listed on notice board?
-
Site map with emergency routes clearly indicated?
-
Is there an "HSE If you are injured" poster displayed?
-
Are details, names and numbers, filled in correctly?
02 Welfare Facilities
-
Are welfare facilities to be inspected this visit?
-
Does Welfare conform to the requirements of CDM 2015 Schedule 2?
-
Toilets working and clean?
-
Sufficient toilet rolls in cubicles?
-
Sinks working and clean?
-
Soap available on all sinks?
-
Separate facilities for ladies?
-
Drying room sufficient in size and warmth?
-
Canteen facilities available?
-
Canteen facilities warm and clean and functional?
-
Food warming facilities clean and functioning?
-
Warm running water readily available?
03 Site Signage
-
Is site signage to be inspected this visit?
-
Are signs indicating 'construction site' on perimeter?
-
Are signs indicating pedestrian segregated routes?
-
Are signs indicating specific PPE required?
-
Have all workers got safe route to workplace?
-
Are signs indicating Welfare facilities, Canteen, Toilets, Drying room etc?
-
Are signs indicating nearest First Aid kit location?
-
Are signs showing assembly points on display?
-
Are signs showing emergency escape routes?
-
Are signs showing specific hazards visible?
04 First Aid
-
Are First Aid Facilities to be inspected today?
-
Are first Aid kits clean and orderly?
-
Are contents within their expiry date?
-
First Aid kits locations easily identified in an emergency?
-
All employees aware of First Aid kit location?
-
First Aiders known to employees & on display?
-
First aider names and contact details on display?
-
Is there a Defibrillator on site?
-
Do First Aid staff know where the Defib is located?
05 Fire Prevention & Emergencies
-
Are Fire & Emergency Procedures to be inspected today?
-
Evacuation plan on display and understood by all staff?
-
Exits and walkways all clear of obstructions?
-
Adequate direction indicator notices for emergency exits?
-
Extinguishers in place and claerly marked for type of fire?
-
Extinguishers accessible and clear of obstructions?
-
Fire alarm system functioning correctly?
-
Fire alarm tested recently & recorded in fire book?
-
Raising the alarm understood by all staff?
-
Has a hot works permit been issued recently?
-
Has previous permit been closed out?
-
Was their a cooling off period within the permit?
-
Was the cooling off period observed and area checked off as fire safe?
06 Site Security
-
Is site security to be inspected this audit?
-
Are site entrance and exit points clearly designated?
-
Is there clear signage requiring people to sign in and out of site?
-
IS site perimeter fenced off appropriately with required site signage educating the public?
-
Are the correct 'Danger of Death' signs fixed to perimeter fencing?
-
All entries and exits closed and locked at night and at weekends?
-
Are site alarm systems workijng correctly?
-
Is site CCTV functioning correctly & accessible?
-
Have inspections and patrols been assessed in the last 4 weeks and still valid?
-
Are inspections and patrols undertaken as required and recorded / monitored?
07 Personal Protective Equipment
-
Is Personal Protective Equipment to be inspected this audit?
-
Is head protection being worn correctly and where required?
-
Is eye protection being worn where required?
-
Hearing protection being worn in designated areas or for required tasks?
-
Is appropriate hand protection being worn where required?
-
Is respiratory protection worn where dust, mist or fumes are present in the workplace?
-
Is footwear in good condition and of the correct type for the job?
-
Are hi-vis vests or clothing being worn at all times on site?
-
Is additional PPE used as and when identified as being required?
-
Are staff aware of the correct PPE they should be wearing?
-
Are visitors made aware of PPE requirements on site?
08 Housekeeping
-
Is site housekeeping to be inspected this audit?
-
Is waste / debris removed on completion of the task?
-
Are tools not in use stored safely and sensibly if not yet returned to longer term storage?
-
Are Access / Egress routes clear of materials?
-
Are materials stored and stacked correctly & safely?
-
Are bins and skips locatedat suitable points around site?
-
Is site generally orderly, with rubbish or waste materials disposed of correctly?
09 Slip, Trip & Fall Safety
-
Is Slip, Trip and falls to be inspected in this audit?
-
Are floor surfaces even and uncluttered?
-
Are entrys and walkways kept clear of materials and clutter?
-
Are walkways adequately and clearly marked?
-
Are all floor surfaces clear from liquid spillages?
-
Are all ground openings fully barricaded or protected with fencing / guarding?
10 Scaffolding
-
Scaffolds to be inspected in this audit?
-
Are scaffolds constructed and erected only by qualified and trained personnel?
-
Scaffold plans submitted and approved?
-
Are scaffolds accessible and clear of unstable objects and trip hazards?
-
IS scaffold adequately attached to a fixed building?
-
Are guardrails installed on all scaffolds to prevent falls?
-
Are scaffold footings safe and stable, secure and free of unstable propping objects?
-
Are scaffolds generally safe and orderly?
-
Have scaffolds been regularly inspected and tagged by qualified person?
11 Hand Power Tools
-
Are hand and power tools to be inspected in this audit?
-
Are all electric tools 110v and not 240v?
-
If applicable are tool guards in place and operable in good working order?
-
Are power cords in good condition free from damage and ware and tare?
-
Power tools in good condition?
-
Are all tools listed on the PUWER register?
-
Are all power tools PAT tested?
-
Battery power tools chargers PAT tested?
-
Are defective tools labelled up, removed from service and disposed?
-
Are power tools stored correctly when not in use?
-
Are the proper tools used for the specific task?
-
Are exhaust and extraction systems supplied and in use for dusty processes?
12 Machinery & Plant
-
General machinery and plant to be inspected in this audit?
-
Have Risk assessments been completed for specific machinery being used today?
-
Are annual maintenance inspections and reports in place for relevant plant and machinery?
-
Do records indicate that maintenance schedules are being adhered to?
-
Where required are pre user daily checks being undertaken?
-
Where applicable, are guards in good working order?
-
Where applicable are machines fitted with emergency stops?
-
Where applicable are emergency stops being tested?
-
Are drip pans being used to prevent pollution?
-
Noise levels monitored & controlled?
-
Sufficient room to use machinery safely?
-
Machine operators trained or certified to use equipment currently being used?
-
Is this training/ certification recorded and documented?
-
Has permit to dig been issued and is it filled in correctly?
-
Have previous permits been closed out correctly?
13 Work at Height
-
Working at height equipment to be inspected in this audit?
-
Are all podiums / ladders of industrial strength and spec?
-
Are stepladders / podiums in good condition?
-
If used for electrical works are ladders non conductive? (Wood, or fibreglass)
-
Are podiums / stepladders being used in conjunction with RAMS?
-
Are higher order controls used for WAH where possible instead of ladders?
-
Are mobile towers being used?
-
Were towers erected by PASMA trained installer?
-
If towers moved, was it done by PASMA trained person?
-
Are podium steps used instead of step ups or step ladders where possible?
14 Electrical Safety
-
Electrical safety to be inspected this audit?
-
Are safety switches installed?
-
Are safety switches tested and recorded?
-
There are no outlets overloaded/ no double adaptors in use?
-
Has portable equipment been tested and registered/tagged?
-
Is there a register of PAT testing including re-test dates?
-
There are no broken plugs or damaged sockets?
-
No power cords laying across walkways?
-
No frayed or damaged leads?
-
Where required there is an emergency shutdown procedure?
15 Confined Spaces
-
Confined spaces safety to be inspected this audit?
-
Is there a suitable confined space permit to use?
-
Do all applicable confined space works have adequate permits granted and documented?
-
Is there a confined space emergency plan in place?
-
Is the confined space being continually monitored throughout the task?
-
Are all workers confined space trained that are undertaking the task?
16 RIDDOR Incident, Injury & Accident Procedures
-
RIDDOR Incident, Injury, Accident procedures to be inspected this audit?
-
Are incident, injury, accident and near miss procedures in place?
-
Date of last recorded incident, accident, injury or near miss?
-
Are adequate reporting forms in place for these events?
-
Are all incidents investigated and can we see an example?
-
Are corrective actions always implimented?
17 Excavations
-
Excavations and ground breaking to be inspected in this audit?
-
Permit to break ground / dig issued?
-
Trench dug in accordance to design specs?
-
Equipment and machinery to be kept 2m away from trench?
-
Spoil kept 2m away from trench?
-
Excess water to be pumped away to safe location?
-
No visible surface cracks in trench?
-
Trenches no deeper than 1.2m?
-
Suitable barricading / guarding applied to trenching area?
-
Suitable levels of signs indicating danger?
-
Lighting, bridges and walkways provided where needed?
-
Specification of works covered by an appropriate Risk Assessment?
-
Emergency exit route provided, steps or sloping end of trench?
-
Stop blocks used where applicable on nearby machinery?
18 COSHH
-
COSHH to be inspected this audit?
-
Appropriate COSHH containment on site?
-
Containment is lockable and under control?
-
Containment correctly labelled with hazard labels?
-
All hazards within container labelled correctly?
-
Combatable materials only stored correctly? (i.e. no acids next to alkalis)
19 LOLER Lifting Equipment
-
Lifting equipment to be inspected this audit?
-
Chains, accessories and slings all listed as inspected?
-
Safe working loads checked on machinery and visible?
-
General lifting plan / RA in place?
20 Manual Handling
-
Is manual handling to be inspected?
-
Has manual handling training been carried out?
-
Has a written assessment been conducted?
-
Assessment in date and signed by relevant staff?
-
Written instructions issued to relevant staff?
-
Is manual handling taking place today, if so is it being done correctly?
General Comments
-
Any further comments or recommendations arising from this inspection?
-
Add any additional relevant photos.
-
Summary of findings during the inspection.
-
Have all required corrective actions been added as Actions to this inspection?
-
Please add any corrective actions to the appropriate questions above before completing this report
Sign Off
-
Name & Signature of Inspector
-
Name & Signature of Site Supervisor / Foreman