Information
-
Document No.
-
Prepared by
-
Company Performing Repair
-
Personnel
-
(Q-RD-01 Exh 56) Pipe Assessment & Repair Report
Assessment & Repair Report
Work Info
-
Date of Assessment(s)
Work Order Info
-
Is Pipe Bare or Coated
-
Work Order #140697
-
atp
-
Type of Units?meters
-
OD (inches)
-
WT (inches)5.6
-
Add Pipe Info
Pipe
-
Pipe/Coil #
-
Heat #11415420
-
Length meters
-
Reason for assessment lot narrow
- Dent
- Bevel
- Lab
- Flat End
- Steel Defect
- Gouge/Deep Grind
- Bent/Cambered
-
Depth (inches)
-
Dimensions of Dent (inches x inches)
-
Add Photos of Damage
Photos
-
Take Photo
-
Deviation (inches)
-
Add Photos of Damage
Photos
-
Take Photo
-
Type of Defect
- Bad Weld
- Sliver(s)
-
Add Photos of Damage
Photos
-
Take Photo
-
Depth (inches)
-
Add Photos of Damage
Photos
-
Take Photo
-
Does the pipe need to be cut?no
-
New Length of Pipe (feet) 17.30meters
-
Was a new pipe created?no
-
Length of Created Pipe (feet)
-
New ID #
-
Amount Scrapped (feet)0.50
-
Comments
-
OD (mm)
-
WT (mm)
-
Add Pipe Info
Pipe
-
Pipe/Coil #
-
Heat #
-
Length (metres)
-
Reason for Assessment
- Dent
- Bevel
- Lab
- Flat End
- Steel Defect
- Gouge/Deep Grind
- Bent/Cambered
-
Depth (mm)
-
Dimensions of Dent (mm x mm)
-
Add Photos of Damage
Photos
-
Take Photo
-
Deviation (mm)
-
Add Photos of Damage
Photos
-
Take Photo
-
Type of Defect
- Bad Weld
- Sliver(s)
-
Add Photos of Damage
Photos
-
Take Photo
-
Depth (mm)
-
Add Photos of Damage
Photos
-
Take Photo
-
Does the pipe need to be cut?
-
New Length of Pipe (metres)
-
Was a new pipe created?
-
Length of Created Pipe (metres)
-
New ID #
-
Amount Scrapped (metres)
-
Comments
-
Work Order #
-
Purchase Order #
-
Coating Type
- Ultrabond RA
- Ultra FBE
- Ultra FBE Abrasion
- Ultrabond IIISE
- Ultra Nap-Gard Gold
- Ultrafoam TA
- Ultrafoam FBE
- Ultrafoam IIISE
- Aerogel
- HI-GARD
- XTRU-THERM
-
Type of Units
-
OD (mm)
-
WT (mm)
-
Add Pipe Info
Pipe
-
BPPC #
-
Pipe/Coil #
-
Heat #
-
Length (metres)
-
Reason for Assessment
- Dent
- Bevel
- Lab
- Flat End
- Steel Defect
- Gouge/Deep Grind
- Bent/Cambered
-
Depth (mm)
-
Dimensions of Dent (mm x mm)
-
Add Photos of Damage
Photos
-
Take Photo
-
Deviation (mm)
-
Add Photos of Damage
Photos
-
Take Photo
-
Type of Defect
- Bad Weld
- Sliver(s)
-
Add Photos of Damage
Photos
-
Take Photo
-
Depth (mm)
-
Add Photos of Damage
Photos
-
Take Photo
-
Does the pipe need to be cut?
-
New Length of Pipe (metres)
-
Was a new pipe created?
-
Length of Created Pipe (metres)
-
Created Pipe BPPC #
-
Amount Scrapped (metres)
-
Comments
-
OD (feet)
-
WT (inches)
-
Add Pipe Info
Pipe
-
BPPC #
-
Pipe/Coil #
-
Heat #
-
Length (feet)
-
Reason for Assessment
- Dent
- Bevel
- Lab
- Flat End
- Steel Defect
- Gouge/Deep Grind
- Bent/Cambered
-
Depth (inches)
-
Dimensions of Dent (inches x inches)
-
Add Photos of Damage
Photos
-
Take Photo
-
Deviation (inches)
-
Add Photos of Damage
Photos
-
Take Photo
-
Type of Defect
- Bad Weld
- Sliver(s)
-
Add Photos of Damage
Photos
-
Take Photo
-
Depth (inches)
-
Add Photos of Damage
Photos
-
Take Photo
-
Does the pipe need to be cut?
-
New Length of Pipe (feet)
-
Was a new pipe created?
-
Length of Created Pipe (feet)
-
Created Pipe BPPC #
-
Amount Scrapped (feet)
-
Comments
-
Signature wayne lennie