Title Page

  • Council Reference No.

  • Location
  • Reason for upgrade, if applicable:

  • Are any dogs at the premises contained and under effective control

  • Conducted on

  • Prepared by

  • Others present:

Barrier Exemptions under Sections 8,9 and 10 of the Act

  • Is an exemption being applied to the property?

Doors

  • Each door giving access to the swimming pool is fitted with self-closing and self-latching mechanism and the latch release height is at least 1500mm above the floor?

  • Door/s self-close and latch from stationary start in any position from fully open to resting on latch

  • There are no footholds wider than 10mm on the door or its frame between the floor and any 1000mm above the floor

  • There are no pet doors or openings to the pool area greater than 100mm

Windows

  • Windows located within a pool area must comply with one of the following:

    a) be at least 1800mm above finished ground level (FGL) in the pool area, OR

    b) be totally covered by bars or mesh screen that is fixed to the building with fasteners that can only be removed by the use of a tool, e.g, a screwdriver or spanner, OR

    c) be restricted to an opening no greater than 100mm using fasteners that can only be removed by the use of a tool, e.g, a screwdriver or spanner

  • Are there any windows located within the swimming pool area with a sill height less than 1800mm from FGL?

  • Do the windows comply with one of the following? <br> <br> a) be totally covered by bars or a mesh screen? <br> OR <br> b) restricted to a maximum opening of 100mm?

Internal Barrier - General

  • WINDOWS opening into pool area restricted?<br><br>If sill is <1800 from ground, window must be either:<br>covered by bars or metal screen. Openings in bars or screen must not be >100mm and must require the use of a tool to remove<br>OR<br>Fixed so it cannot be opened any more than 100mm without the use of a tool

  • Note: Residential building is defined by the Act:

    "residential building means a building (such as a dwelling-house, residential flat building or boarding-house) that is solely or principally used for residential purposes, and includes any structure (such as a garage or shed) that is ancillary to any such building, but does not include:
    (a) a building that merely forms part of a complex of buildings (such as a school or recreational centre) that is principally used for non-residential purposes, or
    (b) a moveable dwelling, or
    (b1) tourist and visitor accommodation, or
    (c) a shed that is ancillary to a swimming pool and the primary purpose of which is to store equipment that is used in connection with the swimming pool (but not a shed of a kind prescribed by the regulations), or
    (d) a building or structure of a kind prescribed by the regulations."

  • Has a barrier been installed to separate the pool from the residential building or place adjoining the premises?

  • Is the barrier a permanent structure?

  • is finished ground level a permanent stable surface?

  • All structures or objects (such as garages, carports, sheds, clothesline or the like) that are not associated with the use of the pool are located outside the pool area?

Internal Pool Barrier -Measurements (non-boundary and less than 1800mm in height)

  • Is the height of the internal barrier at least 1200mm from the top of the fence to finished ground level?

  • Features diagram

    e13753b0-9f6a-4852-939c-7aad0bc9a43a.jfif.jpg
  • No features or objects that would reduce the height of the barrier to be located within 500mm of the OUTSIDE of internal barrier.

  • Features diagram

    62b768f8-f835-45c6-a8ac-9fb5eda86124.jfif.jpg
  • Is the width of all vertical gaps less than 100mm ?

  • Is the gap between bottom of barrier and finished ground level no greater than 100mm ?

  • The pool fence is well maintained and in good state of repair? (eg no holes, damaged or rusted components)

  • Strength & rigidity of openings - (clause 3.1 AS1926.1-2007)

    The conical end of the test object (cone) shall be placed into the opening under test and a force of 150N be steadily applied in an attempt to force the body of the cone through the opening.

  • At the time of inspection is it the Council Officers opinion that the vertical openings within the barrier would pass strength and rigidity testing?

  • Test device used and cone did not pass through any opening when a force of 150N was applied?

Internal Pool Barrier - Non-Climbable Zone - NCZ

  • ****NOTE: Non-climbable zones (NCZ's) do not apply to internal barriers that are 1800mm or more in height which may also be climbable on either or both sides.

  • There are no potential hand holds or foot holds within the 900mm non-climbable zone on the outside of the pool fence in any direction

  • The outside of the pool fence must be clear of any objects such as BBQs, trees, rocks, shrubs and deck chairs that could help a small child climb over the fence

  • There are no horizontal surfaces located within the 900mm x 300mm rectangular non-climbable area inside the pool fencing

  • If perforated or mesh fencing is used, the holes must be 13mm or less

Gates

  • Are there any gates giving access to the pool area?

  • Is the gate kept securely closed?

  • Does gate swing away from pool area?

  • Does gate swing freely through its entire arc of operation? (i.e. cannot be wedged open)

  • Full arc of operation clear of any building or doorway?

  • Is the release point for the latch either: <br> a) no less than 1500mm from finished ground level, <br> <br>OR <br> <br>b) on inside of the barrier at least 150mm below the top of the fence or access point that is 1200mm above ground level AND surrounded by a 450mm shield so it can only be accessed by reaching over the fence or through a latch access point with no gaps more than 10mm present.

  • Lift gate upwards and pull downwards with a force of 250N.<br>The above movement of the gate must not:<br>1. Release the latch<br>2. unhinge the gate<br>3. increase gap under gate to >100mm

  • Latch shall not be able to:<br>1. Be inadvertently adjusted during operation<br>2. Locked in the 'open' position<br>3. Adjusted without use of tools

  • NCZs clear for the gate (hinges)?

Gate Closure

  • Self-closing device closes the gate from any position, with a stationary start and without the application of a manual force and operates the latch

  • Does gate self-close from a stationary start in any position, including while resting on latch?

  • Does gate self-close from resting on latch position?

  • Does gate self-close from partially open position?

  • Does gate self-close from fully open position?

  • Are you aware that it is dangerous and against the law to prop the gate open

Boundary Pool Barrier

  • Does a boundary fence form any part of the pool barrier?

  • Is the barrier at least 1800mm in height, measured from inside the pool area?

  • Features diagram

    9b14a912-1375-4ca2-8386-26cccec3adbb.jfif.jpg
  • NCZ is a quadrant of 900mm radius, measured down from the top of the INSIDE of the boundary pool barrier.

  • NCZ Diagram

    107cdaa2-f6db-4e48-b208-8f6c83c689d8.jfif.jpg
  • No handholds or footholds, or objects or plants that will facilitate climbing in NCZ?

  • Where internal pool barrier intersects into NCZ, the top of internal barrier must: <br><br>- be less than 50mm and intersect at angle between 45 and 130 degrees,<br><br>OR<br><br>- continue at >1800mm for at least 900mm.

  • Is the barrier a permanent structure?

  • Is finished ground level a permanent stable surface?

  • The pool fence must be well maintained and in good state of repair (eg no holes, damaged/rusted panels/rails or broken palings)

  • The gap between the bottom of the boundary fence and the ground is no more than 100mm?

  • Is the width of all vertical gaps <100mm ?

CPR signage

  • Is there a warning notice (CPR Chart) erected?

  • Does the sign contain the required information and diagrams?

  • Is the sign in a prominent position in the immediate vicinity of the swimming pool?

  • Is the sign clearly legible?

Overview

  • I have taken photographs of any non-compliance in the relevant sections.

  • Take photographs showing the entire barrier here.

  • Additional Comments

  • Is there a significant risk to public safety?

  • Is the safety of a person at risk?

  • If Council considers that the safety of a person is at risk if the requirements of a direction were not carried out as soon as possible, it may serve the direction without notice. See section 23(6) of the Act.

  • Is the safety of a person at risk?

  • What is the nature of the risk?

Recommendations

  • Draft Direction

  • Emergency Direction

  • Show Cause

  • Compliance Certificate

  • undefined

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.