AS/NZS 3012:2010 requirements
Clause 1.2
-
All wiring installed according to AS 3000 Wiring rules in addition to AS3012 requirements.
Clause 2.1.2
-
All electrical equipment and lighting supplied from a 30mA RCD protected circuit
Clause 2.1.3
-
Source of supply identified
Clause 2.3.1.1
-
Switchboard readily accessible
Clause 2.3.2.1 (ab)
-
Switchboard of robust construction with a minimum IP23 rating
2.3.2.1 (c)
-
Live parts effectively protected and a warning sign attached along an electric shock Symbol
-
Danger live
-
Electric shock
Clause 2.3.2.1 (d)
-
Insulated tie bars for extension leads to prevent strain on socket/outlet.
Clause 2.3.2.1 (e)
-
Switchboard door is lockable, non removable without tool and fitting with a retention device to stay in open position
Clause 2.3.2.1 (e)
-
Switchboard has means of safe entry of leads and a label: KEEP CLOSED-RUN LEADS THOUGH BOTTON
Clause 2.3.3
-
Switchboard mounted on a pole, structure, wall or suitable designed free standing design
Clause 2.4.1
-
Switchboard has a Main isolation switch capable all downstream circuits.
Clause 2.4.2
-
Main switch capable of being locked or within a lockable space.
Clause 2.4.3
-
Main switch labelled appropriately: MAIN SWITCH or DISTRIBUTION BOARD ISOLATION SWITCH or similar.
Clause 2.5.3
-
Construction wiring installation in appropriate conduit to protect against mechanical damaged.
Clause 2.5.4
-
Construction wiring labelled with yellow tape with words ( construction wiring ) at distance of 5 metres.
Clause 2.6.9
-
Extension leads supported by stands or insulated hooks.
Clause 2.7.1
-
Adequate lighting provided for safe work.
Clause 2.7.2
-
Lighting is mechanically protected.
Clause 2.7.3
-
Emergency lighting adequate for safe exit of workers.
Clause 2.8.1
-
If a lift shaft is present, the final sub-circuit feeding it is locked and tagged to prevent inadvertent isolation of supply.
Clause 2.9
-
Socket outlet in site sheds and other transportation structures are a RCD protected
Clause 3.8.3
-
Portable equipment including power leads are inspected monthly intervals.
Clause 3.8.3
-
Portable RCDs trip time is tested every month.
Clause 3.8.3
-
Switchboard wiring and site sheds are inspected every month interval.
Clause 3.10
-
Register available for equipment and includes records of testing and tagging,RCD trip times result and list of repaired equipment.