Information

  • Document No.

  • Audit Title

  • Client / Site

  • Conducted on

  • Prepared by

  • Location
  • Personnel

15.1 - METAL DETECTION / X-RAY

  • All products must be examined through a metal detection or X-ray detection system

  • Documented justification, based on risk assessment must be given if detection is not in place (agreed with Tesco TM)

15.2 - TESCO COP 375

  • All sites must comply with the requirements of Tesco COP 375 - FB detection systems:

  • Reject log completed - rejects passed back through line 3 times, records kept

  • Memory test completed at start and end of shift

  • Consecutive test completed at start and end of shift, and minimum hourly during the shift

  • Test pieces must be controlled - manufactured with serial number / issued with certificate

15.3 - EQUIPMENT

  • Foreign body detection equipment must be specified as appropriate for the products that are being examined

  • Equipment must be upgraded to improve detection sensitivity where advances in detection are developed

  • The operation and sensitivity of the detector in use must be well understood by relevant site personnel

15.4 - EQUIPMENT - METAL DETECTORS

  • All metal detectors must have the capability of detecting:

  • Ferrous

  • Non-ferrous

  • Stainless steal

15.5 - EQUIPMENT - FOREIGN BODY DETECTION

  • All foreign body detectors must be located as close as possible to the finished packaging point

15.6 - EQUIPMENT - FOREIGN BODY DETECTION (2)

  • All foreign body detectors must have adequate security devices, so only authorised personnel have access to alter settings

15.7 - EQUIPMENT - CONVEYOR SYSTEMS

  • A conveyor type detection system must have:

  • An effective automatic rejection system

  • A locked box to receive rejected product

  • A fully enclosed area around the search head and rejection box

  • A visual or audio alarm system in the event of detection

  • Aspirational - foreign body detector systems include:

  • A data capture system to show pack numbers checked

  • The number of rejects, number and type of tests

  • Foreign body detector system highlights when tests are due

  • Visual or audible alarm system in the event of line fault and fail safe activation

  • The system stops if a test has not been completed

15.8 - EQUIPMENT - IN LINE SYSTEMS

  • In line metal detectors (eg pipe detectors) must have a visual or audible alarm

  • In line metal detectors (eg pipe detectors) must reject product into a dedicated container

15.9 - EQUIPMENT

  • The foreign body detection system must be serviced at regular intervals, either by equipment manufacturer or trained contractors (minimum annually)

15.10 - TESTING OF EQUIPMENT

  • The foreign body detector must be fully operational at the start of production

  • An effective testing method must be in place and all checks must be documented

  • Detectors must be checked at the beginning and end of production, and minimum hourly during the run

  • The test pieces must be placed in the worst case scenario area - on advice from equipment manufacturer.

15.11 - FAIL SAFE SYSTEMS

  • Detector fail safe systems where fitted must be challenged at start and end of day to make sure they are effective - fail safe systems / checks should include:

  • Reject confirmation - start / end production

  • Bin full - start / end production

  • Air pressure low - start / end production

  • Search head failure - start / end production

  • Back-up sensor - start / end production

  • Photo electric cell pre search head - start / end production

15.12 - PLASTERS

  • Each batch of detectable plasters must be checked to ensure they are detected by the lowest sensitivity X-ray

  • Plaster checks must be completed by placing plaster in the product

  • Records must be kept of dectable plaster checks

15.13 - DETECTOR FAILURE

  • In the event of a FB detector failing (test piece/failure to reject product) all product since last good check must be isolated and retested though a unit that has been confirmed to be working correctly

  • A detailed procedure must be in place to handle incidents when FB's are found in product

  • A full investigation must take place to ensure the source of contamination is identified and the risk of other materials being contaminated must be assessed

  • Corrective actions must be put in place to prevent a reoccurrence - details of investigation recorded

15.14 - TRAINING

  • All staff involved with FB detection must be trained in technical and operational requirements

  • All staff involved with FB detection must be trained in principles of FB detection to ensure full understanding of the purpose

15.15 - SIEVING / FILTERING RISK ASSESSMENT

  • Risk assessments must be completed to determine whether a particular material requires sieving / filtering (including liquids)

15.16 - SIEVING

  • Where sieves / filters are used these must be metal detectable or of a contrasting colour to the food

15.17 - EQUIPMENT

  • Equipment used for sieving / filtering must have written inspection procedures

15.18 - EQUIPMENT (2)

  • Sieving / filtering equipment must be inspected for integrity at pre-defined intervals as identified in the risk assessment and recorded

  • Equipment must be accessible to enable inspection

  • Mobile equipment must be uniquely identified to ensure that the integrity of each sieve is being maintained

15.19 - PREVENTATIVE MAINTENANCE

  • Sieves and filters must be included on the preventative maintenance plan

15.20 - TRAINING

  • Training of personnel operating or inspecting the sieving / filtering equipment must take place

15.21 - TRACEABILITY

  • Records must be in place to demonstrate when ingredients have been sieved / filtered (traceable to batch level)

15.22 - STORAGE

  • Stored sieved ingredients must be protected to prevent post sieving contamination

15.23 - SIEVING

  • A sieve matrix must be in place detailing the type of material, sieve size, frequency of inspection and sieve location

15.24 - FOREIGN BODIES

  • Procedures must be in place for actions when foreign bodies are found

  • A full investigation must take place to ensure the source of contamination is identified and corrective action plan implemented (and product dealt with in appropriate manner)

  • Details of the investigation must be recorded

15.25 - SIEVE TAILINGS

  • Sieve tailings must be checked and recorded at regular intervals as defined in the risk assessment

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.