15.1 - METAL DETECTION / X-RAY
-
All products must be examined through a metal detection or X-ray detection system
-
Documented justification, based on risk assessment must be given if detection is not in place (agreed with Tesco TM)
15.2 - TESCO COP 375
-
All sites must comply with the requirements of Tesco COP 375 - FB detection systems:
-
Reject log completed - rejects passed back through line 3 times, records kept
-
Memory test completed at start and end of shift
-
Consecutive test completed at start and end of shift, and minimum hourly during the shift
-
Test pieces must be controlled - manufactured with serial number / issued with certificate
15.3 - EQUIPMENT
-
Foreign body detection equipment must be specified as appropriate for the products that are being examined
-
Equipment must be upgraded to improve detection sensitivity where advances in detection are developed
-
The operation and sensitivity of the detector in use must be well understood by relevant site personnel
15.4 - EQUIPMENT - METAL DETECTORS
-
All metal detectors must have the capability of detecting:
-
Ferrous
-
Non-ferrous
-
Stainless steal
15.5 - EQUIPMENT - FOREIGN BODY DETECTION
-
All foreign body detectors must be located as close as possible to the finished packaging point
15.6 - EQUIPMENT - FOREIGN BODY DETECTION (2)
-
All foreign body detectors must have adequate security devices, so only authorised personnel have access to alter settings
15.7 - EQUIPMENT - CONVEYOR SYSTEMS
-
A conveyor type detection system must have:
-
An effective automatic rejection system
-
A locked box to receive rejected product
-
A fully enclosed area around the search head and rejection box
-
A visual or audio alarm system in the event of detection
-
Aspirational - foreign body detector systems include:
-
A data capture system to show pack numbers checked
-
The number of rejects, number and type of tests
-
Foreign body detector system highlights when tests are due
-
Visual or audible alarm system in the event of line fault and fail safe activation
-
The system stops if a test has not been completed
15.8 - EQUIPMENT - IN LINE SYSTEMS
-
In line metal detectors (eg pipe detectors) must have a visual or audible alarm
-
In line metal detectors (eg pipe detectors) must reject product into a dedicated container
15.9 - EQUIPMENT
-
The foreign body detection system must be serviced at regular intervals, either by equipment manufacturer or trained contractors (minimum annually)
15.10 - TESTING OF EQUIPMENT
-
The foreign body detector must be fully operational at the start of production
-
An effective testing method must be in place and all checks must be documented
-
Detectors must be checked at the beginning and end of production, and minimum hourly during the run
-
The test pieces must be placed in the worst case scenario area - on advice from equipment manufacturer.
15.11 - FAIL SAFE SYSTEMS
-
Detector fail safe systems where fitted must be challenged at start and end of day to make sure they are effective - fail safe systems / checks should include:
-
Reject confirmation - start / end production
-
Bin full - start / end production
-
Air pressure low - start / end production
-
Search head failure - start / end production
-
Back-up sensor - start / end production
-
Photo electric cell pre search head - start / end production
15.12 - PLASTERS
-
Each batch of detectable plasters must be checked to ensure they are detected by the lowest sensitivity X-ray
-
Plaster checks must be completed by placing plaster in the product
-
Records must be kept of dectable plaster checks
15.13 - DETECTOR FAILURE
-
In the event of a FB detector failing (test piece/failure to reject product) all product since last good check must be isolated and retested though a unit that has been confirmed to be working correctly
-
A detailed procedure must be in place to handle incidents when FB's are found in product
-
A full investigation must take place to ensure the source of contamination is identified and the risk of other materials being contaminated must be assessed
-
Corrective actions must be put in place to prevent a reoccurrence - details of investigation recorded
15.14 - TRAINING
-
All staff involved with FB detection must be trained in technical and operational requirements
-
All staff involved with FB detection must be trained in principles of FB detection to ensure full understanding of the purpose
15.15 - SIEVING / FILTERING RISK ASSESSMENT
-
Risk assessments must be completed to determine whether a particular material requires sieving / filtering (including liquids)
15.16 - SIEVING
-
Where sieves / filters are used these must be metal detectable or of a contrasting colour to the food
15.17 - EQUIPMENT
-
Equipment used for sieving / filtering must have written inspection procedures
15.18 - EQUIPMENT (2)
-
Sieving / filtering equipment must be inspected for integrity at pre-defined intervals as identified in the risk assessment and recorded
-
Equipment must be accessible to enable inspection
-
Mobile equipment must be uniquely identified to ensure that the integrity of each sieve is being maintained
15.19 - PREVENTATIVE MAINTENANCE
-
Sieves and filters must be included on the preventative maintenance plan
15.20 - TRAINING
-
Training of personnel operating or inspecting the sieving / filtering equipment must take place
15.21 - TRACEABILITY
-
Records must be in place to demonstrate when ingredients have been sieved / filtered (traceable to batch level)
15.22 - STORAGE
-
Stored sieved ingredients must be protected to prevent post sieving contamination
15.23 - SIEVING
-
A sieve matrix must be in place detailing the type of material, sieve size, frequency of inspection and sieve location
15.24 - FOREIGN BODIES
-
Procedures must be in place for actions when foreign bodies are found
-
A full investigation must take place to ensure the source of contamination is identified and corrective action plan implemented (and product dealt with in appropriate manner)
-
Details of the investigation must be recorded
15.25 - SIEVE TAILINGS
-
Sieve tailings must be checked and recorded at regular intervals as defined in the risk assessment